The manual for Bk SHEETS provides instructions on setting up and operating a power supply model 1520, which involves plugging the device into an AC outlet, turning on the power switch, and adjusting the control knob to achieve the desired voltage. It also includes specifications for various output voltages and currents, as well as guidance on troubleshooting issues related to voltage regulation and ripple noise.
Manual Overview
The Bk SHEETS manual for model 1520 provides detailed guidance on troubleshooting, error codes, diagnostics, calibration, and board-level adjustments for the power supply unit. The unit operates with an input voltage of LISVAC 60Hz and is designed to output various voltage levels including 0-5VDC, 6.3VAC, -8VDC, +8VDC, -250VDC, +250VDC, +125VDC, and -125VDC, each with specific current ratings. For troubleshooting, ensure the power supply is correctly plugged into an AC outlet and the power switch is turned on. If the power light fails to illuminate, check the fuse and input connections. Calibration involves adjusting the control knob to achieve the desired output voltage within specified ranges. Error diagnostics should focus on voltage regulation issues, where load and line variations can cause deviations. Ripple and noise levels should be monitored to remain within 500 mVp-p. Board-level guidance includes verifying output voltage and current levels under both no-load and full-load conditions to ensure they fall within specified limits.
Quick Issues Covered
- Diagnose power-up failures by checking input voltage and fuse status.
- Calibrate output voltage using control knob for precise voltage settings.
- Identify error codes related to voltage regulation and ripple noise issues.
Overview
The product is a power supply with various output voltage and current specifications, including 0-5VDC, 6.3VAC, -8VDC, +8VDC, -250VDC, +250VDC, +125VDC, and -125VDC. It operates with an input voltage of LISVAC 60Hz and is designed to function at an environment temperature of 25°C. The manual covers the operation procedure, which involves plugging the model 1520 into an AC outlet, turning on the power switch, and adjusting the control knob to the desired voltage.
Specifications
- Description: 0-5VDC 3A, 6.3VAC 3A, -8V, +8VDC 100mA
- -250V, -125V, +125V,+250V DC 10mA Power supply
- Input Voltage: LISVAC 60Hz
- Environment Temperature: 25C°
- 0-S5VDC:
- Output Voltage Range 0 5 V
- Min. Output Voltage 100 mV
- Max. Output Voltage 5.5 6.5 V
- Output Current 3 A
- Voltage Regulation:
- Load (0-100% load) 500 mV
- Line (105-125VAC Variation) 200 mV
- Ripple & Noise 500 mVp-p
- 6.3VAC:
- Output Voltage No Load 6.5 8 V
- Output Voltage Full Load 5.8 V
- Output Current 3 A
- -8VDC:
- Output Voltage No Load -7.5 -8.8 V
- Output Voltage Full Load -7.3 -8.5 V
- Output Current 100 mA
- +8VDC:
- Output Voltage No Load +7,5 +8.8 V
- Output Voltage Full Load +7,3 +8.5 V
- Output Current 100 mA
- -250VDC:
- Output Voltage No Load -240 -300 Vv
- Output Voltage Full Load -220 -280 V
- Output Current 10 mA
- +250VDC:
- Output Voltage No Load +240 +300 V
- Output Voltage Full Load +220 +280 Vv
- Output Current 10 mA
- +125VDC:
- Output Voltage No Load +120 +160 V
- Output Voltage Full Load +110 +140 V
- Output Current 10 mA
- -125VDC:
- Output Voltage No Load -120 -160 V
- Output Voltage Full Load -110 -160
- Output Current 10
- No Load Input Current 120
- Full Load Input Current (All Rated Load) 0.55 1
- Fuse
- Dimensions (W X D XH): 7.24 x 7 x 4.33”
- Weight: 6.61 LBS.
Operation
Plug model 1520 into AC outlet. Turn power switch on, power light will come on. Adjust control knob to desired voltage.