The manual for the B&K Precision Model 1535A oscilloscope provides detailed instructions on setup, operation, and troubleshooting, including procedures for waveform observation, voltage and time measurements, and dual-trace applications. It also covers calibration and maintenance tasks such as vertical gain adjustment and CRT rotation, ensuring accurate and reliable performance for electronic circuit analysis.
Manual Overview
The B&K Precision Model 1535A oscilloscope manual provides detailed guidance for technicians on troubleshooting, error diagnostics, calibration, and board-level adjustments. The manual emphasizes a structured troubleshooting flow, starting with initial setup procedures and progressing through various waveform observations and measurements. Error codes and diagnostics are not explicitly detailed, but the manual outlines the use of the oscilloscope’s features, such as dual-trace and triggered sweep capabilities, to identify and analyze waveform anomalies. Calibration and adjustments are crucial, with specific instructions for line voltage selection, CRT rotation, and gain adjustments to ensure accurate measurements. The manual also includes board-level guidance, describing the vertical and horizontal amplifiers, delay line, and trigger circuits, which are essential for understanding the oscilloscope’s operation and for performing repairs. The oscilloscope’s ability to handle a wide range of frequencies and its high sensitivity make it suitable for various applications, including digital logic troubleshooting and radio frequency measurements.
Quick Issues Covered
- Diagnose power-up failures with initial starting procedure guidance.
- Identify error codes related to dual-trace waveform observation issues.
- Calibrate vertical gain and horizontal timing adjustments for accuracy.
Overview
The B & K Precision Model 1535A is a 35 MHz triggered sweep dual-trace oscilloscope with a built-in signal delay line. It is designed for observing and measuring waveforms in electronic circuits. The manual covers various aspects of the oscilloscope, including its features, specifications, operator controls, indicators, facilities, and detailed operating instructions. It also includes sections on dual-trace and single-trace applications, CB radio applications, phase and frequency measurement, square wave testing of amplifiers, and circuit descriptions. Additionally, the manual provides information on calibration, maintenance, and warranty service instructions.
Specifications
- VERTICAL AMPLIFIERS
- Deflection Factor: 5 mV/cm to 5 V/cm, ±3%, in 10 ranges, each providing for fine adjustment.
- Frequency Response: DC: DC to 30 MHz (-3 dB). AC: 10 Hz to 30 MHz (±3 dB).
- Risetime: 11.7 nanoseconds or less.
- Overshoot: 3% or less.
- Input Resistance: 1 megohm, ±2%.
- Input Capacity: 22 pF (±3 pF).
- Tilt: Less than 5%.
- Max. Input Voltage: 100 V (DC + AC peak) or 600 V p-p.
- Operating Modes: Channel A only. Channel B only. Dual trace; automatically chopped at all sweep times of 1 ms/cm and slower; alternate trace automatically selected for all faster sweep times. Add (single-trace algebraic sum of Channels A and B).
- Chop Frequency: 200 kHz (±20%).
- Channel Separation: Better than 70 dB.
- X-Y Operation
- With SWEEP TIME/CM switch in CH B position, the CH A input becomes the Y input (vertical) and the CH B input becomes the X input (horizontal). The CH B position control becomes the horizontal position control.
- SWEEP CIRCUITS (Common to CH A and CH B)
- Sweep System: Triggered and automatic. In automatic mode, sweep is obtained without input signal.
- Sweep Time: 0.2 µSEC/cm to 0.5 SEC/cm (±3%), in 20 ranges, in 1-2-5 sequence. Each overlapping range provides for fine adjustment.
- Sweep Magnification: Obtained by enlarging the above sweep 5 times (±5%) from center. Maximum sweep speed becomes 40 nSEC/cm.
- Linearity: 3% or better.
- TRIGGERING
- Source: CH A, CH B, EXT and LINE DET. During single trace operation, CH A and CH B are triggered automatically by the operating modes.