Rohde & Schwarz HZ530 Operation Manual (PDF)

The manual for the HZ530 Near Field Probes by HAMEG Instruments covers the setup and operation of the probes, including their frequency range, connection specifications, and power requirements. It also provides troubleshooting tips for maintaining signal integrity and ensuring proper connections to external devices, emphasizing the importance of using shielded cables and the potential impact of high-frequency fields on measurement accuracy.

  • Brand: Rohde & Schwarz
  • Model: HZ530
  • Type: operation manual
  • File size: 548.0 KB

Manual Overview

The operation manual for the HZ530 Near Field Probes by HAMEG Instruments provides detailed instructions for troubleshooting, error diagnostics, calibration, and adjustments. The manual emphasizes the importance of using properly shielded cables for connecting measurement devices to external equipment to prevent interference. Troubleshooting involves checking connections and ensuring the use of double-shielded cables, particularly IEEE-Bus cables like the HZ72, to maintain signal integrity. Error diagnostics are facilitated by understanding the frequency response and output impedance of the probes, which range from 100 kHz to 1000 MHz, with an output impedance of 50 ohms. Calibration and adjustments are necessary to maintain accuracy, with specific attention to the maximum input levels and compression points. The manual also provides board-level guidance, highlighting the use of GaAs-FET and monolithic microwave integrated circuits (MMIC) for low noise and high sensitivity. The probes are powered by a 6V DC supply, either from a spectrum analyzer or batteries, with different current requirements for each probe type.

Quick Issues Covered

  • Diagnose EMV issues with near field probes.
  • Calibration of probes for accurate EMV measurements.
  • Error codes for probe connection failures.

Overview

The HZ530 is a set of near field probes designed for electromagnetic compatibility (EMC) diagnostics. The product is manufactured by HAMEG Instruments GmbH, a Rohde & Schwarz company. The manual covers technical data, applications, and safety instructions related to the use of these probes. The probes are used for measuring electromagnetic fields and come with a frequency range of 100 kHz to 1000 MHz, depending on the probe type. The set includes an H-field probe, an E-field probe, and a high-impedance probe, along with necessary cables and a carrying case. The manual also provides information on the product’s compliance with EMC and low-voltage directives.

Specifications

  • Frequenzbereich: 100 kHz-1000 MHz
  • Ausgangsimpedanz: 50 Ohm
  • Anschluss: BNC-Buchse
  • Eingangskapazitat: ca. 2pF (Hochimpedanzsonde)
  • Max. Eingangspegel: +10dBm (zerstorungstfrei)
  • 1dB-Kompressionspunkt: -2dBm (frequenzabhangig)
  • Max. DC-Eingangsspg.: 20V
  • Versorgungsspannung: 6V DC
  • Stromaufnahme: ca. 8mA; H-Feld Sonde, ca. 15mA; E-Feld Sonde, ca. 24mA; Hochimpedanzsonde
  • Sondenmafee (BxHxL): 40x19x195 mm
  • Gehause: Kunststoff innen elektrisch geschirmt
  • Lieferumfang: Transportkoffer, 1 H-Feld Sonde, 1 E-Feld Sonde, 1 Hochimpedanzsonde, 1 BNC-BNC Kabel, 1 Spannungsversorgungskabel
  • Batterien (Typ Mignon) gehoren nicht zum Lieferumfang

Installation / Setup

The source does not provide specific information about installation or setup highlights, including wiring, clearances, calibration, or prerequisites.

Safety & Warnings

The manual includes the following safety warnings/precautions:

1. Data Connections: Connections between measuring devices and external devices (printers, computers, etc.) should only be made with adequately shielded cables. Unless specified otherwise, data cables between the measuring device and the computer should not exceed a length of 3 meters. If multiple interface cables can be connected to a device interface, only one should be connected at a time. Double-shielded connection cables should be used for data cables, and the HZ72 double-shielded cable from HAMEG is suitable for IEEE-Bus connections.

2. Signal Connections: Signal transmission cables between the measuring point and the measuring device should generally be kept as short as possible. Unless a shorter length is specified, signal cables should not exceed a length of 3 meters. All signal cables should be used as shielded cables (coaxial cable – RGS8/U). Proper grounding must be ensured. For signal generators, double-shielded coaxial cables (RG223/U, 8G214/U) must be used.

3. Effects on Measuring Devices: In the presence of strong high-frequency electrical or magnetic fields, unwanted signal components may be introduced into the measuring device through the connected measuring cables, despite careful setup. This does not lead to destruction or shutdown of the measuring device. However, slight deviations in measurement values beyond the specified specifications may occur due to external circumstances in individual cases.

Download PDF (548.0 KB)