Hammarlund HX-50-160 Meter Installation Service Manual (PDF)

The service manual for the Hammarlund 160 Meter Kit-HX-50 provides detailed installation and alignment instructions for adding the 160 meter band kit to the HX-50 Transmitter/Exciter, including specific steps for wire cutting, coil preparation, and soldering. It also outlines the alignment procedure to ensure proper operation, such as peaking the 160 meter coils and setting frequency dials, while emphasizing that the modification should only be performed by experienced personnel with suitable test equipment.

  • Brand: Hammarlund
  • Model: HX-50-160
  • Type: service manual
  • File size: 231.7 KB

Manual Overview

The Hammarlund MANUAL provides detailed instructions for the installation and alignment of the 160 Meter Kit into the HX-50 Transmitter/Exciter. The process begins with removing the transmitter chassis and ensuring that the lead dress of other coils is maintained to avoid disturbing the bandpass characteristics. The manual specifies precise wire lengths and colors for connections, emphasizing careful soldering and positioning to avoid interference with other components. The installation involves preparing and installing various coils, such as the driver, first mixer, and second mixer coils, with specific instructions on soldering leads and capacitors. The alignment procedure requires disconnecting certain components, warming up the system, and using an RF voltmeter to check crystal oscillation. The manual outlines a sequence for peaking the 160 meter coils and provides guidance on setting frequency dials and tuning parameters. It also notes that the 160 meter band can only be properly loaded within a specific frequency range. The parts list includes detailed descriptions and part numbers for components used in the installation.

Quick Issues Covered

  • Diagnose power-up failures with 160 meter band kit installation.
  • Calibrate 160 meter coils using RF voltmeter for optimal performance.
  • Trace circuits with detailed schematics for 160 meter kit installation.

Overview

The product is a 160 Meter Kit for the Hammarlund HX-50 Transmitter/Exciter, available as a factory-installed option (Part No. PL26860-G1) or a field installation option (Part No. PL26860-G2). The manual provides detailed installation and alignment instructions for the kit, emphasizing that the modification should only be attempted by experienced personnel with suitable test equipment.

Installation / Setup

The installation of the 160 meter band kit into the Hammarlund HX-50 Transmitter/Exciter involves several detailed steps. The transmitter chassis must be removed from its case and placed bottom side up. Care must be taken to maintain the original lead dress to avoid disturbing the bandpass characteristics. The process includes cutting wires to specific lengths, preparing and installing various coils (driver, 2nd mixer, and 1st mixer), and soldering connections as per the instructions. The alignment procedure involves disconnecting certain components, using an RF voltmeter to check crystal oscillation, and peaking the 160 meter coils in a specific sequence. The 160 meter band can only be properly loaded from 1.8 to 2.2 mc, with typical dial readings provided for different frequencies. The installation should only be attempted by experienced personnel with suitable test equipment.

Download PDF (231.7 KB)

Leave a Comment