The manual for the Bk 1505 power supply covers the setup process, which involves plugging the device into an AC outlet, turning on the power switch, and adjusting the control knob to the desired voltage. It also provides guidance on operation and troubleshooting, highlighting features such as the current limiter that protects the circuitry and automatically resets after an overload.
Manual Overview
The Bk MANUAL provides detailed guidance for troubleshooting, diagnostics, and maintenance of the 1505 power supply unit. The manual emphasizes a structured troubleshooting flow, starting with verifying the power supply connection and ensuring the power switch is turned on, as indicated by the power light. If issues persist, technicians should check for blown fuses and replace them if necessary. Error codes and diagnostics are not explicitly detailed in the manual, but the unit’s current limiter feature is highlighted as a protective measure against overloads, automatically resetting once the overload condition is resolved. Calibration and adjustments involve using the control knob to set the desired output voltage, ensuring it remains within the specified range of 0.1V to 20V. For board-level guidance, technicians should ensure all connections are secure and inspect for any visible damage or component failure. The manual specifies that the unit operates optimally at an environmental temperature of 25°C, with voltage regulation parameters provided for load and line variations.
Quick Issues Covered
- Diagnose power-up failures with incorrect voltage output.
- Identify error codes related to current limiter activation.
- Use schematics for circuit tracing and fault isolation.
Overview
This product is a 0-20VDC, 500mA power supply with a current limiter for protection against overloads. It automatically returns to normal operation after an overload. The manual covers basic operation, including plugging the model 1505 into an AC outlet, turning on the power switch, and adjusting the control knob to the desired voltage.
Specifications
- 1505
- 0-20VDC, 500mA — Power Supply
- INPUT VOLTAGE LISVAC, 60Hz
- ENVIRONMENTAL TEMPERATURE: 25°C
- Minimum Output Voltage Range 0.1V 20V
- Maximum Output Voltage 20.5V 22V
- Output Current 500mA, typical
- VOLTAGE REGULATION:
- Load (0- 100% load) 200mV
- Line (100-130VAC Variation) 100mV
- Ripple & Noise 100mVp-p
- No Load Input current 60mA
- Full Load Input Current (20V, 500mA) 180mA
- Fuse 0.5A
- Dimensions (W X D X H): 141 mmx 80 mmx 68 mm
- Weight: 0.90 kgs
Operation
Plug model 1505 into AC outlet. Turn power switch on, power light will come on. Adjust control knob to desired voltage.