Sencore-fe160-senior-field-effect-hi-lo-meter-operation-service MANUAL – Service manual (PDF)

The Sencore FE160 Senior Field Effect Hi-Lo Meter manual provides detailed instructions on setting up and operating the meter, including using the shielded test lead and probe, selecting the appropriate range and function, and making various measurements such as DC and AC voltages, currents, and resistances. It also includes troubleshooting guidance, safety precautions, and maintenance tips to ensure accurate and safe operation of the device.

  • Brand: Sencore-fe160-senior-field-effect-hi-lo-meter-operation-service
  • Model: MANUAL
  • Type: service manual
  • File size: 4.4 MB

Manual Overview

The Sencore FE160 Senior Field Effect Meter service manual provides detailed instructions for operation, troubleshooting, and maintenance. The troubleshooting section includes a flowchart to diagnose common issues, guiding technicians through systematic checks of connections, power supply, and component integrity. Error codes and diagnostics are not explicitly listed, but the manual emphasizes verifying correct settings and connections as initial steps. Calibration involves using the OHMS ADJ and ZERO ADJ controls, with instructions for building a meter calibrator for precise adjustments. Board-level guidance includes disassembly instructions and a schematic for identifying and replacing faulty components. The manual also outlines safety precautions, such as using an isolation transformer and discharging capacitors before testing. The FE160 features high input impedance and low voltage ranges, essential for accurate measurements in sensitive circuits. It supports various functions, including DC/AC voltage and current measurements, resistance, and decibel readings, with specific instructions for using the shielded test lead and probe to minimize interference.

Quick Issues Covered

  • Diagnose power-up failures with detailed troubleshooting steps.
  • Calibrate FE160 using step-by-step adjustment procedures.
  • Trace circuits with included schematic and parts list.

Overview

The Sencore FE160 Senior Hi-Lo Field Effect Meter is designed for electronic equipment testing, particularly useful for integrated circuits, transistors, and FETs. It features various voltage and current measurement ranges, both AC and DC, with high input impedance and low applied voltage for ohms ranges. The meter is equipped with a large 7-inch mirrored scale for easy reading and operates on AC power. It includes a shielded test lead and probe with a BNC connector, and offers functions like measuring resistance, decibels, and small leakage currents. The manual covers safety precautions, operation instructions, maintenance, and specifications.

Specifications

  • DC VOLTS
  • 10 positive Ranges: 0.1, 0.3, 1, 3, 10, 30, 100, 300, 1000, 3000
  • 10 Negative Ranges: same as above
  • 10 Zero Center Ranges: -0.05 to 0.05, -0.15 to 0.15, -0.5 to 0.5, -1.5 to 1.5, -5 to 5, -15 to 15, -50 to 50, -150 to 150, -500 to 500, -1500 to 1500
  • Input resistance: 15 megohm, shunted by 90 pf in probe "NORM" 10 pf in 100K "ISOLATION"
  • Accuracy: +1.5%
  • AC rejection: 30 db min
  • AC VOLTS
  • 9 RMS ranges: 0.1, 0.3, 1, 3, 10, 30, 100, 300, 1000
  • 9 PP ranges: 0.28, 0.84, 2.8, 8.4, 28, 84, 280, 840, 2800
  • Frequency compensated
  • Input resistance: 12 megohm
  • Frequency response: 1 db 10Hz – 150KHz, 3 db 5Hz – 500KHz
  • Accuracy: +2.5%
  • DC Current
  • 10 Positive ranges: 0 – 30uA, 100, 300, 1mA, 3, 10, 30, 100, 300, 3A
  • 10 Negative ranges: same as above
  • Internal voltage drop: 0.1V
  • Accuracy: +2%
  • AC Current
  • 10 RMS ranges: 0 – 30uA, 100, 300, 1mA, 3, 10, 30, 100, 300, 3A
  • Internal voltage drop: 0.1V RMS
  • Ohmmeter
  • 8 High Power ranges (1.5V): 0 – 600 ohms, 6K, 60K, 600K, 6M, 60M, 600M, 6000M
  • 7 Low Power ranges (0.08V): 0 – 600 ohms, 6K, 60K, 600K, 6M, 60M, 600M
  • Accuracy: +2 degrees arc
  • Decibel (db)
  • 9 ranges: -20 db, -10, 0, 10, 20, 30, 40, 50, 60
  • Reference: 1mV into 600 ohms
  • General
  • Meter: 7" 500 microamp +2%
  • Multiplies resistors: 1/2% deposited carbon
  • Power: AC line operation 100 – 130 VAC 50 – 60Hz, convertible to 230 VAC
  • Voltage requirements for ohmmeter operation supplied from internal rectifier supply
  • Weight: 6 pounds
  • Dimensions: 3" x 7.5" x 6"

Controls & Indicators

The FE160 Senior Field Effect Meter has two front-panel controls: the OHMS ADJ and the ZERO ADJ. The RANGE SWITCH is a push button used to select the desired range.

Installation / Setup

Refer to the PDF for details.

Operation

The FE160 Senior Hi-Lo Field Effect Meter is equipped with a shielded test lead and probe for accurate AC voltage measurements in the presence of strong electronic and magnetic fields. The probe connects to the FE160 with a BNC type connector and includes a 100K isolation resistor and switch to isolate cable capacity in critical circuits. The probe switch is typically left in the NORM position for most measurements, including DC voltages. The ISOLATION position is used to isolate cable capacity or when using the LO power ohms function in specific circuits. The ISOLATION position should only be used for DC voltage measurements and AC voltages at no more than 60 Hertz to avoid errors.

The FE160 is simple to operate. Users depress the desired function on the Function switch, select the desired range on the Range switch, and measure. The front panel includes two additional controls: the OHMS ADJ and the ZERO ADJ. The range switch is a push button used to select the measurement range.

Troubleshooting & Error Codes

Refer to the PDF for details.

Safety & Warnings

When testing electronic equipment, there are several safety precautions to observe:

1. Always use an isolation transformer on equipment with the chassis tied to one side of the AC power line.
2. Remove power before making test lead connections to high voltage points. If this is not possible, avoid contact with other equipment or metal objects, keep one hand in your pocket, and stand on an insulated floor to reduce shock risk.
3. Discharge filter capacitors before connecting test leads, as they can store a dangerous charge.
4. Ensure equipment is in good condition; broken or frayed test leads can expose the technician to dangerous potentials.
5. Remove test leads immediately after completing the test to reduce shock risk.
6. Do not work alone on hazardous circuits; always have someone nearby in case of an accident. Even minor shocks can lead to more serious accidents, such as falling against equipment or contacting higher voltages.

Download MANUAL Service manual (PDF – 4.4 MB)

Service manual for Sencore FE160 Senior Field Effect Hi-Lo Meter: guides technicians in operation, troubleshooting, and calibration. PDF 4.4 MB.

  • Brand: Sencore-fe160-senior-field-effect-hi-lo-meter-operation-service
  • Model: MANUAL
  • Type: Service manual
  • File size: 4.4 MB

Overview

Brief overview of the product.

Specifications

  • Key spec 1
  • Key spec 2

Controls & Indicators

Control panel/button layout.

Installation / Setup

  1. Step 1…
  2. Step 2…

Operation

Basic usage, modes, cycles.

Troubleshooting & Error Codes

Issue / CodeFix
ExampleHow to fix…

Safety & Warnings

  • Important warning…

Downloads

Download MANUAL service manual (PDF)

Sencore FE160 Senior Field Effect Hi-Lo Meter Overview

The Sencore FE160 Senior Field Effect Hi-Lo Meter is a precision electronic testing instrument designed for measuring the characteristics of field-effect transistors (FETs). It provides accurate readings of gate threshold voltage, leakage current, and other critical parameters essential for troubleshooting and servicing FET devices in various electronic circuits. This meter is widely used by technicians and engineers for quick and reliable component verification and performance analysis.

Main Features and Specifications

  • Measures gate threshold voltage and leakage current of FETs
  • High sensitivity for detecting low-level signals
  • Easy-to-read analog display for real-time measurements
  • Compact and rugged design for field and bench use
  • Battery-operated for portability and convenience
  • Compatible with a wide range of FET types and configurations
  • Includes test leads and probes for versatile connection options

Basic Usage and Operation Tips

To operate the Sencore FE160, first ensure the meter is powered on and the battery is adequately charged. Connect the test leads to the device under test according to the polarity markings. Adjust the meter settings to match the type of FET being tested. Observe the analog needle movement to determine the gate threshold voltage or leakage current. For accurate readings, make sure all connections are secure and avoid touching the test leads during measurement to prevent interference.

Troubleshooting and Maintenance

If the meter fails to power on, check the battery and replace it if necessary. In case of erratic or inconsistent readings, verify that the test leads and probes are intact and properly connected. Clean the contacts regularly to maintain good electrical connectivity. Store the meter in a dry, dust-free environment to prevent damage. If the analog needle sticks or moves sluggishly, calibration or professional servicing may be required.

Safety Reminder

Always use the Sencore FE160 Senior Field Effect Hi-Lo Meter within its specified voltage and current limits to avoid damage or personal injury. Disconnect power from the circuit before testing to prevent electric shock. Handle the device and test leads with care, and avoid exposing the meter to moisture or extreme temperatures.

Leave a Comment