Rohde & Schwarz SWOB5 Z4 Service Manual German (PDF)

The service manual for the Rohde & Schwarz SWOB5-Z4 covers the operation and application of the active demodulator, including detailed instructions on its use with various amplifier modules and the connection of external devices like frequency counters. It also provides guidance on maintenance, emphasizing the protection of connections from damage and contamination, and outlines troubleshooting steps, recommending factory repair for detected defects.

  • Brand: Rohde & Schwarz
  • Model: SWOB5
  • Type: service manual
  • File size: 937.7 KB

Manual Overview

The Rohde & Schwarz SWOB5-Z4 service manual provides detailed instructions for technicians on troubleshooting, calibration, and adjustments of the Aktivdemodulator. The manual emphasizes the importance of using the correct measurement setup for calibration, particularly when adjusting without a Justiereinschub. It specifies the use of precision equipment such as a 50 Ω or 75 Ω precision calibration line, HF power meter, and HF generators at specified frequencies. For troubleshooting, the manual suggests verifying the device’s characteristics at 25 °C using the SWOB5-E1 Log-Verstärker module. If defects are detected, it is recommended to send the unit for factory repair. The manual also includes a functional description of the device, detailing the signal path and the role of various components like the HF amplifier, demodulator, and rectifiers. The board-level guidance includes information on component connections and the impact of adjustments on performance, particularly focusing on the use of trim potentiometers for gain adjustments.

Quick Issues Covered

  • Diagnose HF-Spannung issues with SWOB5-Z4 module.
  • Calibration without adjustment module using precision tools.
  • Check frequency response with Log or Lin amplifier insert.

Overview

The product is the ROHDE & SCHWARZ AKTIVDEMODULATOR SWOB5-Z4, designed for displaying RF voltage in conjunction with the SWOB5-E1 or SWOB5-E2 amplifier modules. It features a broadband amplifier for increased sensitivity and can measure voltages between approximately 20 µV and 50 mV. The manual covers technical data, operation, maintenance, function description, and alignment procedures.

Specifications

  • Impedanz am HF-Eingang 50 Ω oder 75 Ω
  • Anschluss N-Stecker
  • Frequenzbereich 5 – 1000 MHz
  • Welligkeitsfaktor (HF-Eingang) < 1.2
  • Frequenzgang 5 – 1000 MHz < ±1.5 dB
  • Temperaturgang des Vorverstärkers < ±1 dB
  • Maximale Messspannung 50 mV
  • Kompression des Vorverstärkers < 1 dB
  • Maximal zulässige Eingangsspannung 1 V und 2.5 V
  • Kontrollausgang (HF)
  • Impedanz am HF-Ausgang ca. 50 Ω
  • Anschluss BNC-Buchse
  • Spannungsdämpfung zwischen HF-Ein- und HF-Ausgang ca. +1 dB bis 100 MHz, ca. 6 dB bei 1000 MHz
  • Anschluss an Lin- oder Log-Verstärker über 1 m langes Kabel und 7-poligen Stecker
  • Abmessungen (ohne Kabel) 27 x 48 x 170 mm
  • Gewicht ca. 390 g

Installation / Setup

The source does not provide specific information about installation or setup highlights, such as wiring, clearances, calibration, or prerequisites.

Operation

The operation and basic usage steps for the ROHDE & SCHWARZ AKTIVDEMODULATOR SWOB5-Z4 are detailed in sections 2.5 and 2.6 of the SWOB 5 description. The HF control output allows for the connection of a triggerable frequency counter, as mentioned in section 2.2.4 of the SWOB 5 description. When a converting measurement object (e.g., FS-Tuner) is wobbled, frequency measurements can be performed directly in the IF position using the variable brightness marker of the SWOB 5. The option “IF-Markers” allows for the generation of line or pulse markers in the IF position (between 1 MHz and 150 MHz). To do this, the control output of the active demodulator should be connected to the external marker input.

Download PDF (937.7 KB)

Leave a Comment