The operation manual for the Rohde & Schwarz SMY series covers the setup and operation of the instrument via an IEC-bus interface, including setting device addresses, sending commands, and switching between remote and manual operation modes. It also provides troubleshooting guidance through device-specific and common commands, as well as response messages to ensure proper communication and functionality.
Manual Overview
The operation manual for the Rohde & Schwarz SMY series, including models SMY01, SMY02, and SMY43, provides detailed guidance on remote control via the IEC bus interface, adhering to IEC 625-1/IEEE 488/1 and IEEE 488.2 standards. The manual outlines the process for setting the device address, which is factory-set to 28 but can be adjusted between 0 to 30. Troubleshooting involves understanding device messages transmitted over the IEC bus using ASCII code, which includes device-specific and common commands for setting and data requests. Calibration and adjustments can be performed using commands for frequency, level, and modulation settings, with options for internal and external sources. Board-level guidance includes entering and storing correction values for the internal reference frequency and selecting internal test points for diagnostics. The manual emphasizes the compatibility of the command set with other Rohde & Schwarz instruments, ensuring consistent performance across devices.
Quick Issues Covered
- Diagnose remote control issues via IEC bus interface.
- Set and store device address for communication troubleshooting.
- Adjust and verify modulation settings for calibration accuracy.
Operation
The SMY instrument can be operated remotely via an IEC-bus interface, compatible with IEC 625-1/IEEE 488/1 and IEC 625-2/IEEE 488.2 standards. To use the instrument in a basic application, connect it to a controller with an IEC bus cable and set the device address to 28 on the SMY. The first command sent will set the SMY to remote status, indicated by the REMOTE LED. Commands can be sent to reset the instrument, set frequency and level, and configure modulation settings. The device address can be set and displayed in LOCAL mode, and it remains stored even when the instrument is powered off. The address range is 0 to 30, with a factory setting of 28. Device messages are transmitted using ASCII code, and commands include device-specific settings, data requests, and common commands in accordance with IEEE 488.2. All functions available via the SMY keyboard can also be accessed through the IEC bus.