The Rohde & Schwarz SML-Z2 service manual provides detailed instructions for setting up, operating, and troubleshooting the SML service program, including installation procedures, interface selection, and module testing. It also covers calibration processes, both internal and external, and offers guidance on using the program's direct mode for individual bit manipulation and remote control operations.
Manual Overview
The Rohde & Schwarz SML-Z2 Service Kit manual provides detailed guidance for troubleshooting, diagnostics, calibration, and board-level adjustments of the SML instrument. The service program supports module testing and troubleshooting by allowing users to operate internal control bits and access diagnostic points. It is compatible with Windows operating systems and can be controlled remotely via IEC bus or RS232 interface. Installation requires the CVI runtime engine, which is included if not already present. The program interface allows users to select the connection type, view general instrument information, and access error messages. Module tests can be conducted individually or collectively, with diagnostic points color-coded to indicate status. Calibration routines are accessible through the program, with options for internal and external calibrations. Direct Mode enables individual manipulation of setting bits and remote control of instrument functions. The manual also includes a help section for additional guidance on module tests and procedures. External calibration ensures level precision using a power meter, with the program version indicated by smllevco_x.y.
Quick Issues Covered
- Diagnose module faults with color-coded circuit tracing in module tests.
- Resolve power-up failures using detailed error message displays.
- Perform internal and external calibration without additional instruments.
Overview
The SML Service Program supports troubleshooting and module testing for the SML instrument. It allows operation of internal control bits, reading diagnostic points, and transferring basic remote-control commands. The program runs on Windows (95, 98, NT, 2000) and enables remote control via IEC bus or RS232 interface. External level calibration is possible with a connected Rohde & Schwarz NRVD power meter.
Installation / Setup
The installation of the SML Service Program requires inserting the installation disk into the drive and running the “setup.exe” file. The program is compatible with Windows 95, 98, NT, and 2000. During installation, the CVI runtime engine will be installed if not already present. For communication, the program supports IEC bus or RS232 interface connections. The IEC-bus requires entering the bus address, while the RS232 connection uses a null modem cable connected to Port COM1.
Operation
The operation of the SML involves using the SML Service Program, which supports troubleshooting and module testing. The program allows for the operation of internal control bits and reading diagnostic points, as well as transferring basic remote-control commands. It runs on Windows (95, 98, NT, and 2000) and enables remote control via IEC bus or RS232 interface.
To install the program, insert the installation disk and run “setup.exe.” The CVI runtime engine is required and will be installed if not already available. To start the program, click “SML_SERV” in the start menu or run “smliserv.exe” from the program directory.
Upon starting, the user selects the interface type (IEC bus or RS232). For IEC bus, enter the instrument’s address and ensure the connection cable is in place. For RS232, use a null modem cable connected to COM1.
The main view displays information on the SML, firmware, modules, options, temperatures, and error messages. Module tests can be initiated from the “Check” menu, with results displayed in a report. Calibration routines can be accessed via the “Calibrate” menu, distinguishing between internal and external calibrations.
In Direct Mode, individual setting bits of the SML can be manipulated, and diagnostic points can be selected and displayed. Remote control functions are available, and manual operation is possible without terminating the service program. Help information is accessible through the “Help” menu.
Troubleshooting & Error Codes
The manual provides troubleshooting guidance through the SML Service Program, which supports troubleshooting and module testing. It allows operation of internal control bits and reading of available diagnostic points. The program can be used to transfer basic remote-control commands and runs under Windows (95, 98, NT, and 2000). The instrument can be remote-controlled via IEC bus or RS232 interface. The main view of the service program displays general information on the SML, firmware, modules, options fitted, current module temperatures, and error messages. Module tests can be performed for individual function modules, with diagnostic points checked during the tests. Green points indicate components that are okay, while red points indicate diagnostic points out of test tolerances. A report of the tested points can be stored, printed, or copied. The “Diagnostics” menu in Direct Mode allows selection and display of diagnostic points, with output values constantly updated.