The service manual for the VHF-Wattmeter and Matching Indicator by Rohde & Schwarz covers the setup and operation of measuring forward and reflected VHF power in a coaxial line, including the use of a measurement head connected to a display unit with switching and instrument controls. It also provides troubleshooting guidance for calibration and adjustment of the reflection factor and relay control, ensuring proper integration into the automatic switching system of the associated transmitter.
Manual Overview
The service manual for the Rohde & Schwarz VHF-Wattmeter and Anpassungszeiger (Type NAK) provides comprehensive guidance on troubleshooting, diagnostics, calibration, and board-level adjustments. The manual emphasizes the importance of correctly identifying error codes and performing systematic troubleshooting to resolve issues. It includes detailed instructions for calibrating the forward and reflected power measurements using specific potentiometers (R17 for forward and R19 for reflected power). The manual outlines the use of the switch S162 for calibration, reflection, and direct measurement modes, and describes the path of measurement signals through various components. For board-level guidance, the manual details the role of Thyratron switch stages in controlling relay contacts and their integration into the transmitter’s automatic switching system. It specifies the need for a minimum burn-in time of 200 hours for Thyratron tubes to ensure stable ignition points, highlighting the importance of aging new tubes to maintain accuracy. The manual also notes that the device is maintenance-free and provides instructions for connecting the measurement head and operating the device.
Quick Issues Covered
- Diagnose VHF power reflection using error codes.
- Calibrate forward/reflected power with R17 and R19 adjustments.
- Power-up failures linked to Thyratron tube aging.
Specifications
- VHF-Wattmeter und Anpassungszeiger
- Frequenzbereich: 87.5…108 MHz
- Messbereich Vorlaufleistung: 0…12 kW
- Messbereich Rücklaufleistung grob: 0…12 kW
- Messbereich Rücklaufleistung fein: 0..01.2 kW
- Reflexionsfaktor: 0…100 %
- Benötigte Mindest-Vorlaufleistung für die Eichung der Reflexionsfaktoranzeige: 6 kW
- Fehlergrenzen der Leistungsanzeige (bei Sinusspannung): ±10% v. E.
- Fehlergrenzen der Reflexionsfaktoranzeige: ±5% v. E.
- Wellenwiderstand: 60 Ω
- Benötigte Mindestleistung für die Strahlungsüberwachung: 0.3 kW
- Reflexionsabschaltung einstellbar
- Belastbarkeit der Meldekontakte: 60 V, 0-5 A max.
- Netzanschluss: 220 V, 50 Hz/5