Rohde & Schwarz HM8150 Operation Manual (PDF)

The manual for the HAMEG Instruments HM8150 Function Generator provides detailed instructions on setting up the device, including unpacking, installation, and safety precautions, as well as operational guidance such as signal parameter adjustments and interface configuration. It also includes troubleshooting tips, emphasizing the importance of using properly shielded cables to prevent interference and ensuring the device is acclimatized to room temperature before use.

  • Brand: Rohde & Schwarz
  • Model: HM8150
  • Type: operation manual
  • File size: 1.1 MB

Manual Overview

The operation manual for the 17.5 MHz Function Generator by HAMEG Instruments provides detailed guidance on troubleshooting, error diagnostics, and calibration. The manual emphasizes the importance of using double-shielded cables for data and signal connections to minimize electromagnetic interference. Troubleshooting involves checking connections and ensuring cables do not exceed three meters in length. Error codes and diagnostics are addressed through systematic checks of signal parameters and output settings. Calibration and adjustments are necessary for maintaining accuracy, with specific instructions on setting signal parameters like frequency and amplitude. The manual also includes board-level guidance for configuring interfaces and changing settings, ensuring optimal performance. It highlights the importance of adhering to CE marking regulations and maintaining safety standards, such as using the device in dry, enclosed spaces and allowing time for acclimatization after transport. The manual stresses the need for careful handling and storage to prevent damage and ensure longevity.

Quick Issues Covered

  • Diagnose power-up failures with HM8150 function generator.
  • Adjust signal parameters for accurate waveform generation.
  • Troubleshoot error codes specific to HM8150 model.

Overview

The product is a function generator from HAMEG Instruments GmbH, a Rohde & Schwarz company. The user manual covers general information about CE marking, safety instructions, unpacking, setup, transportation, storage, and operation of the device. It also includes details on the controls, signal parameters, frequency, pulse width, amplitude, and other operational modes. The manual provides guidance on the configuration of interfaces, command references, and technical data.

Specifications

  • HM8150
  • Function Generator
  • Options: HO880

Installation / Setup

The source provides some setup highlights for the function generator. It is important to ensure that no more than three measuring devices are stacked on top of each other to avoid instability and excessive heat development. The original packaging should be kept for future transport, as damage due to inadequate packaging is not covered by warranty. The device should be stored in dry, enclosed spaces, and if transported at extreme temperatures, it should be acclimatized for at least 2 hours before use. Upon unpacking, check for completeness and any transport-related damage. The device is built and tested according to safety standards for electrical measuring, control, and laboratory equipment.

Safety & Warnings

1. Datenleitungen: Die Verbindung von Messgeräten mit externen Geräten darf nur mit ausreichend abgeschirmten Leitungen erfolgen. Datenleitungen dürfen eine Länge von 3 Metern nicht überschreiten und sich nicht außerhalb von Gebäuden befinden. Bei Datenleitungen ist auf doppelt abgeschirmtes Verbindungskabel zu achten.

2. Signalleitungen: Messleitungen zur Signalübertragung sollten so kurz wie möglich gehalten werden. Signalleitungen dürfen eine Länge von 3 Metern nicht überschreiten und sich nicht außerhalb von Gebäuden befinden. Alle Signalleitungen sind als abgeschirmte Leitungen (Koaxialkabel) zu verwenden.

3. Auswirkungen auf die Geräte: Bei starken hochfrequenten elektrischen oder magnetischen Feldern kann es zu Einspeisung unerwünschter Signalanteile kommen, was zu geringfügigen Abweichungen der Anzeige- und Messwerte führen kann.

4. Allgemeine Hinweise: Nicht mehr als drei Messgeräte übereinander stapeln, um Instabilität und übermäßige Wärmeentwicklung zu vermeiden. Transportschäden aufgrund mangelhafter Verpackung sind von der Gewährleistung ausgeschlossen. Die Lagerung muss in trockenen, geschlossenen Räumen erfolgen. Nach Transport bei extremen Temperaturen sollte eine Akklimatisierungszeit von mindestens 2 Stunden eingehalten werden.

Download PDF (1.1 MB)