Overview

Refer to the PDF for details.

Specifications

  • Display: 4 digits. Characters 0-9, ACFHPU.
  • Fault detection accuracy: 100% probability of detecting single-bit errors; 99.998% probability of detecting multiple-bit errors.
  • Composite signature: Maximum number of signatures: No limit.
  • Signature memory: Signatures recallable by probe switch: The last 32 signatures triggered by probe switch.
  • Clock: Maximum frequency: 25 MHz. Minimum clock time: 15 nsec in high or low state.
  • Pulse stretching: 100 msec on gate and unstable lamps.
  • Setup time: 10 ns with 0.2V overdrive. (Data to be valid at least 10 ns before selected clock edge.)
  • Hold time: 0 ns. (Data to be held until occurrence of selected clock edge.)
  • Start, stop, qualifier: Setup time: 20 ns with 0.2V overdrive. (Data to be valid at least 20 ns before selected clock edge.)
  • Minimum gate length: 1 clock cycle (1 data bit) between START and STOP.
  • Maximum gate length: No limit.
  • Minimum timing between gates: 1 clock cycle between STOP and START.
  • Probe: 50k0 to ground nominal.
  • Pod: 100kQ to ground nominal.
  • CMOS sense: 7000 nominal.
  • Probe: ±150V continuous. ±250V intermittent. 250V ac for 1 minute.
  • Pod: ±20V continuous. ±140V intermittent. 140V ac for 1 minute.
  • CMOS sense: 20V dc maximum.
  • Logic one: 70% of sensed voltage nominal.
  • Logic zero: 30% of sensed voltage nominal.
  • Pod: 50% of sensed voltage nominal.
  • Signature: Four seven-segment digits with decimal point.
  • Lamps: Key status: Recall, edit, signature latch, unstable latch, qualify mode, timing polarities.
  • Programmable: Remote, talk, listen, SRQ.
  • Status: Composite signature, gate, unstable.
  • Probe: Logic levels indicated: High, low, open and pulsing with 100 msec stretching.
  • Minimum pulse width: 10 nsec.
  • Switch: Under normal operation, pushing probe switch enters signatures into memory.
  • Selectable power: 115V 410%-25% ac line, 48-440 Hz. 230V +10%-15% ac line, 48-66 Hz. 25VA maximum.
  • Operating environment: Temperature: 0-55°C. Humidity: 95% RH at +40°C. Altitude: 4600M (15,000 ft.)
  • Size: 89 mm high X 216 wide 279 mm deep.
  • Net weight: 2.4 kg (5.3 lbs)
  • Shipping weight: 4.1 kg (9 Ibs)
  • Logic one: 2 Volt + 24.3
  • Logic zero: 0.8 Voit + .3-.2
  • Pod: 1.4 Volt £.6

Controls & Indicators

Refer to the PDF for details.

Installation / Setup

The SOURCE does not provide specific information on installation or setup highlights such as wiring, clearances, calibration, or prerequisites.

Operation

Refer to the PDF for details.

Troubleshooting & Error Codes

“”

Safety & Warnings

Refer to the PDF for details.

Download 3 Service manual (PDF – 3.2 MB)

HP-5006A Model 3 Service Manual: Troubleshoot and calibrate with step-by-step instructions. File size: 3.2 MB.

  • Brand: Hp-5006a-operating-service-sec-1
  • Model: 3
  • Type: Service manual
  • File size: 3.2 MB

Overview

Brief overview of the product.

Specifications

  • Key spec 1
  • Key spec 2

Controls & Indicators

Control panel/button layout.

Installation / Setup

  1. Step 1…
  2. Step 2…

Operation

Basic usage, modes, cycles.

Troubleshooting & Error Codes

Issue / Code Fix
Example How to fix…

Safety & Warnings

  • Important warning…