The Heathkit operation manual provides detailed instructions for setting up and operating the system, which includes differential input operational amplifiers, a booster amplifier, and regulated DC power supplies, along with specifications for output voltage, current ranges, and impedance. It also covers troubleshooting aspects such as voltage regulation, ripple voltage, and power requirements, ensuring optimal performance and maintenance of the equipment.
Manual Overview
The Heathkit SCHEMATICS operation manual provides detailed guidance on troubleshooting, diagnostics, and calibration for the system’s components. The system includes four differential input operational amplifiers, a booster amplifier, and regulated DC power supplies. Troubleshooting involves checking the gain and phase shift characteristics, which are critical for maintaining operational integrity. Technicians should use an AC VTVM and a phasemeter for diagnostics, ensuring the operational amplifiers maintain a DC gain of 21,000 and a frequency response as specified. Calibration requires adjustments for DC zero using provided controls, and bias settings for amplifier operation modes. The booster amplifier outputs a maximum of +20 mA at +50 V DC, with a gain of approximately 0.8. The power supplies offer regulated outputs with minimal ripple and noise, and technicians should ensure voltage regulation remains within specified limits. For board-level guidance, attention should be paid to output impedance and rise time specifications to ensure proper functionality. The manual also outlines power requirements and auxiliary power connections for additional equipment integration.
Quick Issues Covered
- Diagnose power-up failures with regulated power supply checks.
- Calibrate amplifier gain and phase shift using specified test equipment.
- Trace circuit issues with detailed operational amplifier schematics.
Specifications
- Contents of System:
- Four Differential Input Operational Amplifiers
- One Booster Amplifier
- One DC+ Power Supply, regulated
- One DC- Power Supply, regulated
- Operational Amplifiers:
- DC Gain, Open Loop: 21,000 (87 db), typical
- Output Voltage Range: -50 V DC to +50 V DC
- Output Current Range: -1 ma to +1 ma with 50 K® load
- Output Impedance: Less than 1.5 2 with 1:1 feedback as shown
- Rise Time: 12 » sec (with 1:1 feedback as shown)
- Booster Amplifier:
- Maximum Output: +20 ma at +50 V DC
- Gain: Approximately 0.8
- Output Impedance: Less than 0,2 Q
- Regulated Power Supplies:
- DC+ Output Voltage Range: Regulated +275 to +325 volts (approximately)
- DC- Output Voltage Range: Regulated -275 to -325 volts (approximately)
- Voltage Regulation (Each Supply): Output variation less than 1% from no load to full load at 300 volts
- Ripple Voltage (Each Supply): Less than 10 millivolts rms ripple, jitter, and noise
- Output Impedance (Each Supply): Less than 10 2 from 5-100,000 cps
- Power Requirements:
- AC Input: 105-125 volts, 50/60 cps
- Filament Power Only: 44 watts
- Total Power Required: 94 watts at quiescent operating conditions
- Fuses: Two 3/4 ampere slow-blow fuses
- Auxiliary Power Connector:
- Location: Octal socket on rear of unit, and banana jacks on front panel
- Power Available: +300 volts at 20 ma and -300 volts at 20 ma with unit in operation
- General:
- Dimensions: 11-1/4" wide x 6-3/8" high x 12.7/8" deep
- Net Weight: 15-3/4 lbs
- Shipping Weight: 17 lbs