The service manual for Hallicrafters bulletins provides detailed instructions for installing, setting up, and troubleshooting an "S" meter circuit in various Hallicrafters communications receivers, including models S-85, S20R, and SX62. It includes guidance on mechanical and electrical zero settings, ensuring the correct insertion of the circuit into the plate return of the RF or IF stage, and addressing potential issues such as weak tubes or incorrect resistor values.
Manual Overview
The Hallicrafters service manual provides detailed instructions for installing and calibrating an “S” meter in various models of Hallicrafters communications receivers, such as the S-85, S20R, and SX62. The manual emphasizes the importance of correctly integrating the meter into the receiver’s circuitry, specifically in the plate return of the first RF or IF tube, to measure signal strength accurately. Key conditions include ensuring the stage is controlled by AVC and that the tube’s screen current does not pass through the meter. Calibration involves setting mechanical and electrical zero points, with specific steps to adjust the meter using the RF gain control and other settings. Troubleshooting guidance addresses potential issues like weak tubes or incorrect resistor values, and suggests using an isolation transformer to prevent electrical hazards. The manual includes diagrams and part specifications for proper installation and adjustment of the “S” meter circuit.
Quick Issues Covered
- Diagnose electrical zero issues in Hallicrafters S-85 model.
- Calibrate 'S' meter for accurate signal strength readings.
- Use schematics for circuit tracing in S-20R and S-38E models.
Installation / Setup
The installation of an “S” meter in Hallicrafters receivers involves several key steps. The meter circuit is typically inserted in the plate return of the first RF tube, as this stage is generally more sensitive. The stage chosen must be controlled by AVC, and the tube’s screen current must not pass through the meter. After installation, both mechanical and electrical zero settings are required. Mechanical zero is set with the pointer adjustment screw, while electrical zero involves adjusting the RF gain or sensitivity control to maximum, with the AVC on and other controls set as specified. If difficulties arise in obtaining electrical zero, variations in the circuit or checking components such as tubes and resistors may be necessary. An isolation transformer is recommended for safety in certain receiver types.
Safety & Warnings
An “S” meter installed according to the provided diagram will have one lead connected to B-, and in this type of receiver, B- is connected to one side of the AC line. To prevent a hazard, an isolation transformer (STANCOR type P-6410 or equivalent) must be used. Additionally, the meter terminals “A” must be completely covered, and the connecting lead “B” must be the rubber-covered 115 volts AC type.