Drake PC801 Instruction Manual (PDF)

The Drake PC8071 Passive Combiner manual covers the setup of combining outputs from up to eight Audio/Video Modulators or Channel Processors into a single coaxial cable, with specifications including a frequency range of 5-1000 MHz and an insertion loss of 12 dB nominal. It also provides guidance on operation and troubleshooting, including a monitor output at the front panel and details on warranty service for defects in material or workmanship.

  • Brand: Drake
  • Model: PC801
  • Type: manual
  • File size: 24.0 KB

Manual Overview

The Drake PC801 Passive Combiner is designed to merge outputs from up to eight audio/video modulators or channel processors into a single coaxial output. It can be mounted in a standard 1-3/4″ H x 19″ W rack space and features a front panel monitor output. For increased capacity, multiple combiners can be linked. The unit operates within a frequency range of 5-1000 MHz, with a nominal insertion loss of 12 dB and a maximum of 14.5 dB. It provides a port-port isolation of 30 dB nominal and 25 dB minimum, and can handle a maximum input of +60 dBmV per input. The impedance is set at 75 Ohms, with a return loss of 16 dB nominal. The monitor test point is set at -20 dB relative to the output. The device meets FCC Part 76 shielding requirements and operates in temperatures ranging from -20° C to +50° C. For troubleshooting, ensure proper maintenance and installation, as improper handling can void the three-year limited warranty. For service, contact R.L. Drake Company with the necessary product and purchase details.

Quick Issues Covered

  • Diagnose insertion loss issues exceeding 14.5 dB maximum.
  • Troubleshoot port-port isolation below 25 dB minimum.
  • Use schematics for tracing monitor output circuit at -20 dB.

Overview

The DRAKE PC8071 Passive Combiner allows for the combination of outputs from up to 8 sets of Audio/Video Modulators or Channel Processors onto a single coaxial cable. It can be mounted in a standard 1-3/4″ H x 19″ W rack space and includes a monitor output on the front panel. Additional units can be combined to increase capacity. The device operates within a frequency range of 5-1000 MHz, has an insertion loss of 12 dB nominal, and supports a maximum input of +60 dBmV per input. It meets FCC Part 76 shielding requirements and is covered by a three-year limited warranty.

Specifications

  • Frequency Range: 5-1000 MHz.
  • Insertion Loss: 12 dB nominal, 14.5 dB maximum.
  • Port-port Isolation: 30 dB nominal, 25 dB minimum.
  • Maximum Input: +60 dBmV, each input.
  • Impedance: 75 Ohms.
  • Return Loss (all ports): 16 dB nominal, 14 dB minimum.
  • Monitor Test Point: -20 dB (referenced to output).
  • Shielding: Meets FCC Part 76 requirements when operated at rated input levels.
  • Operating Temperature: -20° C to +50° C.
  • Size: 19" W x 1.75" H x 3.7" D.

Installation / Setup

The DRAKE PC8071 Passive Combiner mounts in a standard 1-3/4″ H x 19″ W rack space. It allows for the combination of outputs from up to 8 sets of Audio/Video Modulators or Channel Processors onto a single coaxial cable. A monitor output is available on the front panel. The frequency range is 5-1000 MHz, with an insertion loss of 12 dB nominal and 14.5 dB maximum. The maximum input is +60 dBmV per input, and the impedance is 75 Ohms. The unit meets FCC Part 76 shielding requirements when operated at rated input levels. The operating temperature range is -20° C to +50° C.

Download PDF (24.0 KB)