The manual for B+K Precision Models 2120B and 2125A 30 MHz Dual-Trace Oscilloscopes provides detailed instructions on setup, operation, and troubleshooting, including safety precautions to prevent electrical shock during use. It covers features such as dual trace display, calibrated voltage and time measurements, and sweep functionalities, along with maintenance tips like fuse replacement and periodic adjustments.
Manual Overview
The manual for the BK Precision Models 2120B and 2125A 30 MHz Dual-Trace Oscilloscopes provides detailed guidance on troubleshooting, error diagnostics, calibration, and board-level adjustments. It emphasizes safety precautions due to the risk of electrical shock when working with high voltage equipment. The manual advises using isolation transformers for “hot chassis” equipment to prevent shock hazards and potential damage to test instruments. Troubleshooting involves understanding the dual-trace features, including the ability to display two waveforms simultaneously and perform algebraic operations on them. Calibration is crucial for accurate voltage and time measurements, with the manual detailing the use of calibrated ranges for both vertical and horizontal controls. The oscilloscope features a rectangular CRT with adjustable trace rotation and sweep magnification for detailed waveform analysis. Periodic adjustments and calibration checks are necessary to maintain performance, with guidance provided for these procedures. The manual also includes instructions for fuse replacement and line voltage selection, ensuring the oscilloscope operates safely and effectively.
Quick Issues Covered
- Diagnose power-up failures with initial starting procedure guidance.
- Calibrate voltage measurements using 10 calibrated ranges from 5 mV/div.
- Trace circuits with detailed schematics for dual-trace oscilloscopes.
Overview
The product is a 30 MHz dual-trace oscilloscope, specifically the B+K Precision Models 2120B and 2125A. These oscilloscopes are designed to offer higher performance than competitors’ entry-level models, with features such as high sensitivity, calibrated voltage and time measurements, and dual trace capabilities. The manual covers test instrument safety, features, specifications, controls and indicators, operating instructions, maintenance, and additional appendices.
Specifications
- 30 MHz dual-trace oscilloscope
- Models 2120B and 2125A
- Rectangular CRT with 8 x 10 cm viewing area
- 30 MHz bandwidth
- 3 mV/div sensitivity
- 1 mV/div and 2 mV/div sensitivity using PULL XS gain control
- 10 calibrated voltage ranges from 5 mV/div to 5 V/div
- Vertical gain fully adjustable between calibrated ranges
- 23 calibrated time ranges from 2 S/div to 0.1 µS/div
- Delayed sweep with 23 calibrated ranges from 2 S/div to 0.1 µS/div (Model 2125A)
- X10 sweep magnification
- Dual vertical input channels
- Selectable single trace or dual trace
- Alternate or chop sweep selectable
- Sum and difference capability for channel waveforms
- Electrically adjustable trace rotation from front panel
- 0%, 10%, 90%, and 100% markers for rise time measurements
Safety & Warnings
Normal use of test equipment exposes users to electrical shock dangers, especially when testing in areas with exposed high voltage. Electrical shocks with currents as low as 10 milliamps can stop the heart, and voltages as low as 35 volts can be hazardous. To reduce risks, follow these safety precautions:
– Avoid unnecessary exposure to high voltage in the equipment under test. Remove housings and covers only when necessary.
– Turn off equipment when making test connections in high-voltage circuits and discharge high-voltage capacitors after removing power.
– Familiarize yourself with the equipment being tested and the location of high voltage points, but be aware that high voltage may appear unexpectedly in defective equipment.
– Use insulated floor material or a large, insulated floor mat to stand on, and an insulated work surface for equipment. Ensure these surfaces are not damp or wet.
– Use the “one hand in the pocket” technique while handling an instrument probe to avoid creating a ground return path.
– When using a probe, touch only the insulated portion and never the exposed tip.
– Remember that ac line voltage is often present on some power input circuits even if the equipment is turned off.
– For equipment with a two-wire ac power cord, treat it as “hot chassis” and use an isolation transformer between the ac outlet and the equipment under test.
– Never work alone; someone should be nearby to provide aid if necessary. Training in CPR is highly recommended.