BK Precision 1822 Instruction Service Manual (PDF)

The service manual for the B&K Precision Model 1822 Universal Counter covers setup, operation, and troubleshooting, including instructions for frequency, period, and time interval measurements, as well as safety precautions to prevent electrical shock. It also provides guidance on maintenance, calibration, and troubleshooting, with details on circuit descriptions and signal conditioning controls to ensure accurate measurements.

  • Brand: BK Precision
  • Model: 1822
  • Type: service manual
  • File size: 5.1 MB

Manual Overview

The B&K Precision Model 1822 Universal Counter is designed for frequency measurements ranging from 5 Hz to 175 MHz, featuring an eight-digit display that offers high resolution. The manual emphasizes safety precautions due to potential electrical hazards when using the device. It provides detailed troubleshooting guidance, including diagnostics and error code interpretations, to assist technicians in identifying and resolving issues. Calibration and adjustments are crucial for maintaining accuracy, with specific instructions on how to perform these tasks. The manual also includes board-level guidance, offering circuit board maps and schematic analyses for the display, amplifier, and main boards. This information is essential for technicians performing repairs or maintenance at the component level. Additionally, the manual covers the installation of optional components, such as the TCXO, and provides instructions for line voltage conversion and fuse replacement. Overall, the manual serves as a comprehensive resource for technicians to ensure the proper operation and maintenance of the Model 1822 Universal Counter.

Quick Issues Covered

  • Diagnose power-up failures with self-test procedures.
  • Troubleshoot using error codes for frequency and period measurements.
  • Calibrate frequency measurements for accuracy and precision.

Overview

The B&K Precision Model 1822 Universal Counter is a high-quality, lightweight instrument capable of frequency measurements from 5 Hz to 175 MHz. It features an eight-digit display providing up to 0.1 Hz resolution at frequencies below 10 MHz and 1 Hz resolution up to 175 MHz. The counter offers various operating modes, including frequency, period, and frequency ratio measurements, with easy-to-interpret readouts and several signal conditioning controls to prevent miscounting. The manual covers safety precautions, specifications, operating instructions, circuit descriptions, maintenance, calibration, and warranty information.

Safety & Warnings

Normal use of the instrument exposes users to electrical shock hazards, especially when measurements are taken in equipment with high voltage. Electrical shocks causing 10 milliamps of current through the heart can be lethal. Voltages as low as 35 volts dc or ac rms are dangerous and can produce lethal currents under certain conditions. Higher voltages pose an even greater threat. To reduce risk, users should:

1. Avoid making measurements at circuit points exceeding the maximum input voltages listed in the specifications to prevent instrument damage. Even at low voltage points, avoid touching high voltage points. AC line voltage may be present in power input circuits even if the equipment is off.
2. Familiarize themselves with the equipment being tested and its high voltage points, but remember that high voltage can appear unexpectedly in defective equipment.
3. Use the “one hand in the pocket” technique when handling an instrument probe to avoid contact with grounded metal objects.
4. Use insulated floor material or a large insulated floor mat and an insulated work surface, ensuring they are not damp or wet.
5. Connect the counter’s ac power cord only to a 3-wire outlet to ensure the instrument’s chassis, connectors, and probe ground lead are at earth ground.

Download PDF (5.1 MB)