BK Precision 1743B Instruction Manual (PDF)

The manual for the B+K Precision Model 1743B DC Power Supply provides detailed instructions on setting up and operating the power supply, including adjusting voltage and current outputs, and using the LED displays to monitor performance. It also offers troubleshooting tips, such as handling potential electrical shock hazards and ensuring proper grounding to prevent damage and ensure user safety.

  • Brand: BK Precision
  • Model: 1743B
  • Type: manual
  • File size: 1.1 MB

Manual Overview

The B+K Precision Model 1743B DC Power Supply manual provides detailed guidance on troubleshooting, error diagnostics, and calibration for technicians. The power supply offers a 0-35V, 0-6A output with dual 4-digit LED displays for voltage and current monitoring. Troubleshooting focuses on ensuring proper connections and understanding the automatic crossover between constant voltage and constant current modes. Error diagnostics involve monitoring the LED indicators, which signal operational modes and potential issues. Calibration and adjustments can be made using coarse and fine controls for both voltage and current. The manual emphasizes the importance of safety precautions, particularly when dealing with high voltage scenarios, and provides specific instructions for safe operation. Board-level guidance includes the use of reverse polarity protection and current limiting features to prevent damage. The power supply’s output is isolated from the chassis, allowing flexible connections, including series or parallel configurations for increased voltage or current output. The manual also covers maintenance tasks such as fuse replacement and line voltage conversion for international use.

Quick Issues Covered

  • Diagnose constant voltage/current mode crossover issues.
  • Error codes for voltage/current regulation faults.
  • Schematics for circuit tracing and fault isolation.

Overview

The B+K Precision Model 1743B is a DC power supply designed for general-purpose use, providing 0-35 volts DC output and 0-6 amps current output, both adjustable with coarse and fine controls. It features dual 4-digit LED displays for monitoring voltage and current, with the voltage meter in green and the current meter in red. The power supply can operate in constant voltage or constant current modes, with smooth and automatic crossover between the two. It includes safety features such as reverse polarity protection and overload protection. The output is isolated from chassis and earth ground, allowing flexible connections. The instrument is suitable for various applications, including electronics servicing, manufacturing, design labs, and education.

Specifications

  • OUTPUT VOLTAGE
  • 0 to 35 VDC, coarse and fine adjustment
  • OUTPUT CURRENT
  • 0 to 6 A, coarse and fine adjustment
  • CONSTANT VOLTAGE OPERATION
  • Voltage Regulation
  • Line (108- 132) <0.2%+2 mV
  • Load (no load to full load) <0.04% +2 mV
  • Recovery Time <100 us typical
  • Ripple Voltage
  • RMS <I mV
  • Temperature Coefficient
  • 0 to+40 C <300 PPM? C
  • METERING
  • Voltmeter 4 digit Green LED Display.
  • Range 0 to 99.99 V
  • Accuracy (0.5% + 9 digits)
  • Ammeter 4 digit Red LED Display.
  • Hi Range 0 to 9.999 A
  • Accuracy (0.5% + 9 digits)
  • POWER REQUIREMENTS
  • Domestic: 120 VAC +10%, 60 Hz
  • International: 120, 220, 230, 240 VAC, 50/60 Hz
  • POWER CONSUMPTION
  • Approximately 420 Watts or less at full load

Safety & Warnings

Normal use of test equipment involves some risk of electrical shock, especially when testing in areas with exposed high voltage. A current of 10 milliamps passing through the heart can be fatal, and voltages as low as 35 volts DC or AC RMS can be dangerous under certain conditions. To minimize risk, follow these safety precautions:

1. The power supply output itself poses little risk of shock, as it produces a maximum of 35 volts DC. However, if connected to an external high voltage, a significant shock hazard may arise. Be cautious in the following scenarios:
a. When testing “hot chassis” equipment, ensure it is unplugged or use an isolation transformer to prevent shock hazards.
b. If the equipment under test is powered and uses high voltage, the power supply outputs may reach high voltage levels. Do not float the power supply output to more than 100 volts peak relative to chassis or earth ground.
c. If the equipment is off but normally uses high voltage, discharge high-voltage capacitors before testing, as they may retain voltage even when the equipment is off.

2. Use a polarized 3-wire AC outlet to ensure the power supply chassis, case, and ground terminal are properly grounded, reducing shock risk.

3. Avoid unnecessary exposure to high voltage. Only remove housings and covers when necessary, and turn off equipment when making test connections in high-voltage circuits. Always discharge high-voltage capacitors after removing power.