BK Precision 1653-1655 Instruction Manual (PDF)

The manual for the B&K Precision Models 1653 and 1655 Isolated-Variable AC Power Supplies provides detailed instructions for setup, operation, and troubleshooting, including safety precautions for handling high voltage and using the equipment as an isolation transformer or variable AC voltage source. It also includes specific guidance on using the Model 1655 as a leakage tester and offers maintenance tips such as fuse replacement and calibration adjustments.

  • Brand: BK Precision
  • Model: 1653-1655
  • Type: manual
  • File size: 1.5 MB

Manual Overview

The manual for the B&K Precision Models 1653 and 1655 Isolated-Variable AC Power Supplies provides detailed guidance on troubleshooting, error diagnostics, calibration, and board-level adjustments. For troubleshooting, the manual outlines using the power supply as an isolation transformer, a variable AC voltage source, and for electrical load measurement. It emphasizes the importance of safety, advising technicians to avoid connecting two “hot chassis” devices to isolated output outlets simultaneously to prevent shock hazards. The manual includes specific error codes and diagnostics, particularly for the Model 1655, which features a new leakage probe with a momentary contact switch for testing. Calibration and adjustments are covered, with instructions on preventive maintenance, fuse replacement, and auto-transformer brush replacement. The manual also details the use of the power supply’s built-in meter for voltage and current measurements, and provides specifications for voltage adjustment range and meter accuracy. Safety precautions are emphasized throughout, including the use of insulated materials and the “one hand in the pocket” technique to minimize electrical shock risks.

Quick Issues Covered

  • Diagnose power-up failures with Model 1655 AC power supply.
  • Calibration adjustments for voltage and current sensing accuracy.
  • Circuit tracing using detailed schematics for fault isolation.

Overview

The product described is an isolated-variable AC power supply, specifically the B & K-Precision Models 1653 and 1655. These models are used for servicing electrical equipment by providing a variable output voltage from 0 to 150 VAC and handling output currents up to 3 amps continuous for Model 1655 and 2 amps for Model 1653. The manual covers safety precautions, features, specifications, operating instructions, maintenance, and troubleshooting. It emphasizes the importance of using the power supply safely, particularly when working with high voltage, and includes specific revisions for Model 1655 related to a new leakage probe design.

Specifications

  • OUTPUT ISOLATION
  • Leakage less than 0.1 mA (25°C, 50% relative humidity).
  • VOLTAGE ADJUSTMENT RANGE
  • 0-150 VAC, with input at 120 VAC.
  • VOLTAGE/CURRENT SENSING
  • Sine wave average, calibrated in RMS.
  • MAXIMUM CURRENT (Isolated)
  • Model 1655: 3 A continuous, 4 A intermittent (0-130 V).
  • Model 1653: 2 A continuous.
  • METER SCALES
  • Model 1655: Voltage: 0-150 V. Current: 0-4 A. Volt-Amps (Voltage Set to 120): 0-240 VA. Leakage: 0-5 mA.
  • Model 1653: Voltage: 0-150 V. Current: 0-2 A.
  • METER ACCURACY (25°C)
  • Model 1655: Volts: ±2% of full scale (calibrated @ 120 VAC). Current: ±3% of full scale. Leakage: ±5% @ 500 µA.
  • Model 1653: Volts: ±5% of full scale (calibrated @ 120 VAC). Current: ±5% of full scale.
  • INPUT POWER
  • Model 1655: 120 VAC ±10%, 60 Hz, 600 VA.
  • Model 1653: 120 VAC ±10%, 60 Hz, 300 VA.

Safety & Warnings

Never connect two pieces of “hot chassis” equipment to ISOLATED OUTPUT outlets simultaneously due to a serious shock hazard. An electrical shock causing 10 milliamps of current through the heart can stop most human heartbeats and cause death. Voltage as low as 35 volts dc or ac rms should be considered dangerous and hazardous. Remove housings and covers only when necessary and turn off equipment while making test connections in high-voltage circuits. Discharge high-voltage capacitors after removing power. Familiarize yourself with the equipment being tested and the location of its high voltage points. Use an insulated floor material or a large, insulated floor mat to stand on, and an insulated work surface. Use the “one hand in the pocket” technique while handling an instrument probe. Be careful to avoid contacting a nearby metal object that could provide a ground return path. When testing ac powered equipment, remember that line voltage is usually present on some power input circuits even if the equipment is turned off. Never work alone; someone should be nearby to render aid if necessary. Training in CPR (cardiopulmonary resuscitation) first aid is highly recommended.

Download PDF (1.5 MB)