BK Precision 1623A Instruction Manual (PDF)

The BK Precision Instruction Manual for models 1620A to 1627A covers the setup, operation, and troubleshooting of DC regulated power supplies, including instructions for confirming supply range, precautions for connecting output terminals, and details on operating environments. It also provides guidance on operation procedures such as stand-alone, serial, and parallel operations, as well as maintenance tasks like fuse replacement and calibration of voltage and current meters.

  • Brand: BK Precision
  • Model: 1623A
  • Type: manual
  • File size: 472.0 KB

Manual Overview

The BK Precision DC Regulated Power Supplies models 1620A through 1627A are designed for precise voltage and current control, suitable for laboratory, industrial, and telecommunication applications. These units can operate in constant voltage or constant current mode, with outputs adjustable via coarse and fine knobs. They feature separate voltage and current meters for accurate monitoring. Troubleshooting involves checking the power supply range and ensuring proper connection of output terminals. The manual emphasizes the importance of using the units within specified ambient conditions and avoiding obstruction of natural convection cooling. Calibration procedures include voltage and current calibration, as well as voltmeter and ammeter alignment. For board-level guidance, the manual details the replacement of the main fuse and provides specifications for input and internal fuses. Error diagnostics are facilitated by the unit’s ability to operate in master/slave configurations for parallel operation, enhancing output current capability, or in series to increase output voltage.

Quick Issues Covered

  • Diagnose power-up failures with LED indicators on front panel.
  • Calibrate voltage and current using coarse and fine adjust knobs.
  • Trace circuits using detailed schematics in the manual.

Overview

The BK Precision models 1620A, 1621A, 1622A, 1623A, 1626A, and 1627A are DC regulated power supplies designed for high precision and continuous variability. They can operate in constant voltage or constant current modes, with outputs adjustable from 0 up to the rated values. These units feature separate voltage and current meters for simultaneous monitoring and include coarse and fine adjust knobs for precise adjustments. They support serial and parallel connections for increased output voltage and current, respectively. Suitable for laboratory, industrial, field service, hobby, and telecommunication applications, these power supplies offer excellent line and load regulations, low ripple and noise characteristics, and protection against overload and short circuits.

Specifications

  • Voltage range: 0 to rated values for respective model
  • Current range: 0 to rated values for respective model
  • Separate voltage and current meters
  • Coarse and fine adjust knobs
  • Natural convection cooling system
  • Input voltage: 220V, 50Hz (or on request)
  • Operating ambient temperature: 5 to 40°C
  • Dimensions: 205 x 115 x 270mm
  • Weight: Approximate 6Kgs (1620A, 1622A, 1626A), Approximate 7.4Kgs (1621A, 1623A, 1627A)
  • Input fuse: AC 100V, 110V, 120V 3AF; AC 220V, 230V, 240V 2AF
  • Internal fuse: 500mAF

Controls & Indicators

1. POWER SWITCH: Turns the power supply ON-OFF; the switch lights up when the unit is ON.
2. DC VOLTMETER: Indicates the present output voltage. (Analog meter for models 1620, 1622, 1626 and LED meter for models 1621, 1623).
7. VOLTAGE FINE ADJUST: Fine adjust knob for the output voltage in voltage mode.
8. CURRENT COARSE ADJUST: Coarse adjust knob for current limiting point and current value in constant current mode.

Installation / Setup

The source does not provide specific information on installation or setup highlights such as wiring, clearances, calibration, or prerequisites.

Operation

The manual provides information on the operation and modes of the BK Precision DC Regulated Power Supplies. These models can operate in constant voltage or constant current mode, with outputs adjustable from 0 up to the rated values for each model. The units feature separate voltage and current meters for simultaneous monitoring, and adjustments can be made using coarse and fine adjust knobs. The power supplies can be connected in parallel in a master/slave configuration to increase output current, or in series to increase output voltage. The manual also outlines precautions for use, such as ensuring the unit is used within its specified range and operating environment.

Safety & Warnings

The manual includes the following safety warnings and precautions:

1. The units must be used within their specified range. Before plugging into the AC supply outlet, check whether the input rating conforms with your local supply. For certain models, a voltage selector is available, and it should be switched to the appropriate position before use.

2. The units are floating type power supplies. For ordinary use, ensure that the MASTER/SLAVE switch on the rear panel is set to the MASTER position, and either the (+) output terminal or the (-) terminal is connected to the GND terminal (chassis GND) via the shorting bar.

3. Use the unit within the specified ambient temperature range listed in the specification table.

4. Because the unit is cooled by natural convection, do not place objects on top to block the convection. Avoid placing the unit on or near any heat-emitting devices or using multiple units in a stacked configuration. For best results, use the unit in an environment that is as well cross-ventilated as possible.