BK Precision 810A Instruction Manual (PDF)

The manual for the Bk Model 810A Capacitance Meter provides detailed instructions for setting up the device, including battery and fuse replacement, as well as operating procedures such as selecting the appropriate range and zeroing the meter. It also includes troubleshooting tips, such as addressing overrange indications and ensuring accurate measurements by properly zeroing the device and using the correct test leads.

  • Brand: BK Precision
  • Model: 810A
  • Type: manual
  • File size: 160.6 KB

Manual Overview

The Bk Model 810A Capacitance Meter by Dynascan Corporation is designed for measuring capacitance with a 3-1/2 digit LCD display. It features a range switch for selecting measurement ranges from 200 pF to 20 mF and a zero adjustment knob for calibration. Troubleshooting involves checking the display for overrange or low battery indicators. An overrange is shown by a “1” in the most significant digit, while “LO BAT” indicates a low battery. For accurate measurements, ensure the meter is zeroed at the 200 pF range using the zero adjust control. If the meter reads as if an open capacitor is under test, check and replace the fuse in the battery compartment with a 1/4 A, 250 V fuse. The meter is protected against damage from charged capacitors by this fuse. For testing, capacitors can be directly plugged into the test sockets or connected via test leads. Always discharge capacitors before testing and avoid applying voltage to the test jacks to prevent damage. The meter uses an AC measurement method, which is more reliable for high-leakage capacitors.

Quick Issues Covered

  • Diagnose overrange errors with '1' on most significant digit.
  • Calibrate using ZERO ADJ knob for accurate readings.
  • Access schematics for circuit tracing and fuse replacement.

Overview

The product is a capacitance meter, model 810A, manufactured by Dynascan Corporation. The manual covers maintenance, controls, indicators, battery replacement, fuse access, operating procedures, and specifications. It provides detailed instructions on using the meter, including setting the power switch, selecting ranges, zero adjustment, and measurement procedures. The manual also includes safety precautions, useful conversions, and general specifications such as display type, overrange indication, battery life, and dimensions.

Specifications

  • Display: 3-1/2 digit liquid crystal display (LCD) with a maximum reading of 1999
  • Overrange Indication: "1" or "— 1"
  • Low Battery Indication: LO BAT displayed
  • Sampling Rate: 2.5 measurements per second, nominal
  • Excitation Voltage: 3.2 volts maximum
  • Zero Adjustment Range: ± 20 pF
  • Power: Single standard 9 V battery, NEDA 1604 or equivalent
  • Battery Life: 100 hours typical (alkaline)
  • Dimensions: (H x W x D) 1 3/8” x 3-9/16" x 7 1/2” (35 mm x 90 mm x 190 mm), 1 3/4” (45 mm) max height at tilted window
  • Weight: 13 oz (365 g) including battery
  • Supplied Accessories: Test leads (pair), spare fuse (1)

Controls & Indicators

Display: 3-1/2 digit display with a maximum reading of 1999, indicates measured value, overrange, and low battery.
POWER Switch: Turns instrument ON and OFF.
Range Switch: Selects range (200 pF to 20 mF).
Capacitor Test Sockets: For direct plug-in of capacitor leads.
Jack (Black): Common, reference, or foil side test lead jack.
Jack (Red): Positive polarized test lead input for red lead.
ZERO ADJ Knob: Used for zeroing readout.
Tilt Stand: Converts to hanger strap if removed and reattached.

Operation

Set the POWER switch to the ON position. Select the 200 pF range and adjust the ZERO ADJUST control until the least significant digit is close to zero. Connect test leads to the (+) and (–) capacitor test jacks if necessary, and zero the meter with the leads connected. For measurement, insert the capacitor leads into the test socket or connect them using test leads. Select the appropriate range for known capacitances or start with the 200 pF range for unknown capacitances and increase until a reading is obtained. Turn the POWER switch to OFF when measurements are complete to conserve battery life.

Safety & Warnings

Remove discharged disposable batteries immediately to prevent damage from battery leakage. Never apply a voltage to the test jacks of the meter, as serious internal damage may result. Fully discharge any capacitor to be measured. Observe polarity when testing polarized capacitors. Do not attempt to measure any component “in circuit.”