<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>BULLETINS &#8211; ManualsPlus</title>
	<atom:link href="https://www.manualsplus.com/tag/bulletins/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.manualsplus.com</link>
	<description>ManualsPlus.com — The Electronics &#38; Lab Manual Library.</description>
	<lastBuildDate>Sun, 21 Dec 2025 13:30:35 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.manualsplus.com/wp-content/uploads/2025/08/cropped-Screenshot-2025-08-22-at-12.36.44-32x32.png</url>
	<title>BULLETINS &#8211; ManualsPlus</title>
	<link>https://www.manualsplus.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Hallicrafters-sx-62-s-meter-circuit-service BULLETINS – Service manual (PDF)</title>
		<link>https://www.manualsplus.com/hallicrafters-sx-62-s-meter-circuit-service-bulletins-service-manual-pdf/</link>
					<comments>https://www.manualsplus.com/hallicrafters-sx-62-s-meter-circuit-service-bulletins-service-manual-pdf/#respond</comments>
		
		<dc:creator><![CDATA[Erik from ManualsPlus]]></dc:creator>
		<pubDate>Sun, 21 Dec 2025 10:13:20 +0000</pubDate>
				<category><![CDATA[Hallicrafters]]></category>
		<category><![CDATA[Manuals]]></category>
		<category><![CDATA[BULLETINS]]></category>
		<guid isPermaLink="false">https://www.manualsplus.com/hallicrafters-sx-62-s-meter-circuit-service-bulletins-service-manual-pdf/</guid>

					<description><![CDATA[Service manual for Hallicrafters SX-62 S-Meter Circuit BULLETINS; assists technicians in troubleshooting and calibrating. File size: 1.0 MB.]]></description>
										<content:encoded><![CDATA[<p><!-- mpse:generated:start --></p>
<p class="mpse-brief">The service manual for Hallicrafters bulletins provides detailed instructions for installing, setting up, and troubleshooting an &quot;S&quot; meter circuit in various Hallicrafters communications receivers, including models S-85, S20R, and SX62. It includes guidance on mechanical and electrical zero settings, ensuring the correct insertion of the circuit into the plate return of the RF or IF stage, and addressing potential issues such as weak tubes or incorrect resistor values.</p>
<ul class="mpse-meta" style="margin:0 0 .75rem 1.2rem;list-style:disc;">
<li><strong>Brand:</strong> Hallicrafters</li>
<li><strong>Model:</strong> BULLETINS</li>
<li><strong>Type:</strong> service manual</li>
<li><strong>File size:</strong> 1.0 MB</li>
</ul>
<h2 id="manual-overview">Manual Overview</h2>
<p>The Hallicrafters service manual provides detailed instructions for installing and calibrating an &#8220;S&#8221; meter in various models of Hallicrafters communications receivers, such as the S-85, S20R, and SX62. The manual emphasizes the importance of correctly integrating the meter into the receiver&#8217;s circuitry, specifically in the plate return of the first RF or IF tube, to measure signal strength accurately. Key conditions include ensuring the stage is controlled by AVC and that the tube&#8217;s screen current does not pass through the meter. Calibration involves setting mechanical and electrical zero points, with specific steps to adjust the meter using the RF gain control and other settings. Troubleshooting guidance addresses potential issues like weak tubes or incorrect resistor values, and suggests using an isolation transformer to prevent electrical hazards. The manual includes diagrams and part specifications for proper installation and adjustment of the &#8220;S&#8221; meter circuit.</p>
<h3>Quick Issues Covered</h3>
<ul>
<li>Diagnose electrical zero issues in Hallicrafters S-85 model.</li>
<li>Calibrate &#039;S&#039; meter for accurate signal strength readings.</li>
<li>Use schematics for circuit tracing in S-20R and S-38E models.</li>
</ul>

<h2 id="overview">Overview</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="specs">Specifications</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="controls">Controls &amp; Indicators</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="setup">Installation / Setup</h2>
<p>The installation of an &#8220;S&#8221; meter in Hallicrafters receivers involves several key steps. The meter circuit is typically inserted in the plate return of the first RF tube, as this stage is generally more sensitive. The stage chosen must be controlled by AVC, and the tube&#8217;s screen current must not pass through the meter. After installation, both mechanical and electrical zero settings are required. Mechanical zero is set with the pointer adjustment screw, while electrical zero involves adjusting the RF gain or sensitivity control to maximum, with the AVC on and other controls set as specified. If difficulties arise in obtaining electrical zero, variations in the circuit or checking components such as tubes and resistors may be necessary. An isolation transformer is recommended for safety in certain receiver types.</p>
<h2 id="operation">Operation</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="troubleshooting">Troubleshooting &amp; Error Codes</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="safety">Safety &amp; Warnings</h2>
<p>An &#8220;S&#8221; meter installed according to the provided diagram will have one lead connected to B-, and in this type of receiver, B- is connected to one side of the AC line. To prevent a hazard, an isolation transformer (STANCOR type P-6410 or equivalent) must be used. Additionally, the meter terminals &#8220;A&#8221; must be completely covered, and the connecting lead &#8220;B&#8221; must be the rubber-covered 115 volts AC type.</p>
<div class="manual-preview" style="margin-top:1.5rem;"><iframe src="https://manualsplus.nyc3.digitaloceanspaces.com/wp-content/uploads/2025/12/21101332/Hallicrafters-SX-62-S-meter-circuit-Service-bulletins.pdf#toolbar=1&#038;view=FitH" width="100%" height="900" style="border:none;" loading="lazy"></iframe></div>
<p class="mpse-download-bottom" style="margin-top:1rem;"><a class="button button-primary" href="https://manualsplus.nyc3.digitaloceanspaces.com/wp-content/uploads/2025/12/21101332/Hallicrafters-SX-62-S-meter-circuit-Service-bulletins.pdf" target="_blank" rel="nofollow noopener">Download BULLETINS Service manual (PDF – 1.0 MB)</a></p>
<p><!-- mpse:generated:end --></p>
<p>Service manual for Hallicrafters SX-62 S-Meter Circuit BULLETINS; assists technicians in troubleshooting and calibrating. File size: 1.0 MB.</p>
<ul>
<li><strong>Brand:</strong> Hallicrafters-sx-62-s-meter-circuit-service</li>
<li><strong>Model:</strong> BULLETINS</li>
<li><strong>Type:</strong> Service manual</li>
<li><strong>File size:</strong> 1.0 MB</li>
</ul>
<h2 id="overview">Overview</h2>
<p>Brief overview of the product.</p>
<h2 id="specs">Specifications</h2>
<ul>
<li>Key spec 1</li>
<li>Key spec 2</li>
</ul>
<h2 id="controls">Controls &#038; Indicators</h2>
<p>Control panel/button layout.</p>
<h2 id="setup">Installation / Setup</h2>
<ol>
<li>Step 1…</li>
<li>Step 2…</li>
</ol>
<h2 id="operation">Operation</h2>
<p>Basic usage, modes, cycles.</p>
<h2 id="troubleshooting">Troubleshooting &#038; Error Codes</h2>
<table>
<thead>
<tr>
<th>Issue / Code</th>
<th>Fix</th>
</tr>
</thead>
<tbody>
<tr>
<td>Example</td>
<td>How to fix…</td>
</tr>
</tbody>
</table>
<h2 id="safety">Safety &#038; Warnings</h2>
<ul>
<li>Important warning…</li>
</ul>
<h2 id="downloads">Downloads</h2>
<p><a class="button button-primary" href="https://manualsplus.nyc3.digitaloceanspaces.com/wp-content/uploads/2025/12/21101332/Hallicrafters-SX-62-S-meter-circuit-Service-bulletins.pdf" target="_blank" rel="nofollow noopener">Download BULLETINS service manual (PDF)</a></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.manualsplus.com/hallicrafters-sx-62-s-meter-circuit-service-bulletins-service-manual-pdf/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Hallicrafters-s-85-s-meter-circuit-service BULLETINS – Service manual (PDF)</title>
		<link>https://www.manualsplus.com/hallicrafters-s-85-s-meter-circuit-service-bulletins-service-manual-pdf/</link>
					<comments>https://www.manualsplus.com/hallicrafters-s-85-s-meter-circuit-service-bulletins-service-manual-pdf/#respond</comments>
		
		<dc:creator><![CDATA[Erik from ManualsPlus]]></dc:creator>
		<pubDate>Sun, 21 Dec 2025 09:25:00 +0000</pubDate>
				<category><![CDATA[Hallicrafters]]></category>
		<category><![CDATA[Manuals]]></category>
		<category><![CDATA[BULLETINS]]></category>
		<guid isPermaLink="false">https://www.manualsplus.com/hallicrafters-s-85-s-meter-circuit-service-bulletins-service-manual-pdf/</guid>

					<description><![CDATA[Hallicrafters S-85 S-Meter Circuit Service Manual: Troubleshoot and calibrate S-meter circuits efficiently. File size: 1.0 MB.]]></description>
										<content:encoded><![CDATA[<p><!-- mpse:generated:start --></p>
<p class="mpse-brief">The Hallicrafters service manual provides instructions for installing an &quot;S&quot; meter circuit in various models of their communications receivers, detailing the necessary conditions and adjustments for optimal performance. It includes guidance on setup, such as mechanical and electrical zero settings, and troubleshooting tips for issues like inability to obtain electrical zero due to factors like weak tubes or incorrect resistor values.</p>
<ul class="mpse-meta" style="margin:0 0 .75rem 1.2rem;list-style:disc;">
<li><strong>Brand:</strong> Hallicrafters</li>
<li><strong>Model:</strong> BULLETINS</li>
<li><strong>Type:</strong> service manual</li>
<li><strong>File size:</strong> 1.0 MB</li>
</ul>
<h2 id="manual-overview">Manual Overview</h2>
<p>The Hallicrafters service manual provides detailed instructions for installing and calibrating an &#8220;S&#8221; meter in various models, including the S-85, S20R, SX62, and others. The &#8220;S&#8221; meter measures the plate current of an RF or IF stage controlled by Automatic Volume Control (AVC) to indicate signal strength. Installation involves inserting the meter circuit in the plate return of the first RF tube, ensuring the stage is controlled by AVC and that the tube&#8217;s screen current does not pass through the meter. Calibration requires setting mechanical and electrical zero points. Mechanical zero is set with the meter off, aligning the pointer to the last calibration mark. Electrical zero involves tuning the receiver to a quiet spot, removing the antenna, and adjusting the zero set control to align the pointer to the &#8220;S&#8221; unit zero. Troubleshooting includes checking for weak tubes, incorrect cathode resistor values, and residual AVC voltage. An isolation transformer is recommended for safety in certain installations.</p>
<h3>Quick Issues Covered</h3>
<ul>
<li>Diagnose inability to obtain electrical zero in S-meter circuit.</li>
<li>Adjust mechanical and electrical zero settings for accurate calibration.</li>
<li>Trace S-meter circuit schematics for models S-85, S-20R, SX-62.</li>
</ul>

<h2 id="overview">Overview</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="specs">Specifications</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="controls">Controls &amp; Indicators</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="setup">Installation / Setup</h2>
<p>The installation of an &#8220;S&#8221; meter in Hallicrafters receivers involves several key steps and considerations. The meter is designed to measure the plate current of an RF or IF stage controlled by AVC, which varies inversely with signal strength. The installation process includes:</p>
<p>1. Circuit Placement: The circuit is typically inserted in the plate return of the first RF tube for best results, though it can also be placed in the plate return of an IF tube if necessary. The chosen stage must be controlled by AVC, and the tube&#8217;s screen current must not pass through the meter.</p>
<p>2. Mechanical and Electrical Zeroing: <br />
   &#8211; Mechanical zeroing involves turning the set off and adjusting the pointer to the last calibration mark on the right side of the meter scale.<br />
   &#8211; Electrical zeroing requires setting the RF gain to maximum, turning off the noise limiter and BFO, and tuning to a quiet spot on the dial. The antenna is then shorted to ground, and the zero set control is used to align the meter pointer to &#8220;S&#8221; unit zero.</p>
<p>3. Troubleshooting Electrical Zero: If zeroing is difficult, possible causes include weak tubes, incorrect cathode resistor values, or residual AVC voltage. Adjustments may involve shorting the RF gain control to check for absolute zero resistance.</p>
<p>4. Safety Precautions: For certain receiver models, an isolation transformer is necessary to prevent hazards, as one side of the AC line is connected to B-. The meter terminals must be covered, and the connecting lead should be rubber-covered for 115 volts AC.</p>
<p>These steps ensure proper installation and calibration of the &#8220;S&#8221; meter for accurate signal strength indication.</p>
<h2 id="operation">Operation</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="troubleshooting">Troubleshooting &amp; Error Codes</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="safety">Safety &amp; Warnings</h2>
<p>An &#8220;S&#8221; meter installed according to the provided diagrams will have one lead connected to B-, and in this type of receiver, B- is connected to one side of the AC line. To prevent a hazard, an isolation transformer (STANCOR type P-6410 or equivalent) must be used. Additionally, the meter terminals &#8220;A&#8221; must be completely covered, and the connecting lead &#8220;B&#8221; must be the rubber-covered 115 volts AC type.</p>
<div class="manual-preview" style="margin-top:1.5rem;"><iframe src="https://manualsplus.nyc3.digitaloceanspaces.com/wp-content/uploads/2025/12/21092513/Hallicrafters-S-85-S-meter-circuit-Service-bulletins.pdf#toolbar=1&#038;view=FitH" width="100%" height="900" style="border:none;" loading="lazy"></iframe></div>
<p class="mpse-download-bottom" style="margin-top:1rem;"><a class="button button-primary" href="https://manualsplus.nyc3.digitaloceanspaces.com/wp-content/uploads/2025/12/21092513/Hallicrafters-S-85-S-meter-circuit-Service-bulletins.pdf" target="_blank" rel="nofollow noopener">Download BULLETINS Service manual (PDF – 1.0 MB)</a></p>
<p><!-- mpse:generated:end --></p>
<p>Hallicrafters S-85 S-Meter Circuit Service Manual: Troubleshoot and calibrate S-meter circuits efficiently. File size: 1.0 MB.</p>
<ul>
<li><strong>Brand:</strong> Hallicrafters-s-85-s-meter-circuit-service</li>
<li><strong>Model:</strong> BULLETINS</li>
<li><strong>Type:</strong> Service manual</li>
<li><strong>File size:</strong> 1.0 MB</li>
</ul>
<h2 id="overview">Overview</h2>
<p>Brief overview of the product.</p>
<h2 id="specs">Specifications</h2>
<ul>
<li>Key spec 1</li>
<li>Key spec 2</li>
</ul>
<h2 id="controls">Controls &#038; Indicators</h2>
<p>Control panel/button layout.</p>
<h2 id="setup">Installation / Setup</h2>
<ol>
<li>Step 1…</li>
<li>Step 2…</li>
</ol>
<h2 id="operation">Operation</h2>
<p>Basic usage, modes, cycles.</p>
<h2 id="troubleshooting">Troubleshooting &#038; Error Codes</h2>
<table>
<thead>
<tr>
<th>Issue / Code</th>
<th>Fix</th>
</tr>
</thead>
<tbody>
<tr>
<td>Example</td>
<td>How to fix…</td>
</tr>
</tbody>
</table>
<h2 id="safety">Safety &#038; Warnings</h2>
<ul>
<li>Important warning…</li>
</ul>
<h2 id="downloads">Downloads</h2>
<p><a class="button button-primary" href="https://manualsplus.nyc3.digitaloceanspaces.com/wp-content/uploads/2025/12/21092513/Hallicrafters-S-85-S-meter-circuit-Service-bulletins.pdf" target="_blank" rel="nofollow noopener">Download BULLETINS service manual (PDF)</a></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.manualsplus.com/hallicrafters-s-85-s-meter-circuit-service-bulletins-service-manual-pdf/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Hallicrafters-s-77-s-meter-circuit-service BULLETINS – Service manual (PDF)</title>
		<link>https://www.manualsplus.com/hallicrafters-s-77-s-meter-circuit-service-bulletins-service-manual-pdf/</link>
					<comments>https://www.manualsplus.com/hallicrafters-s-77-s-meter-circuit-service-bulletins-service-manual-pdf/#respond</comments>
		
		<dc:creator><![CDATA[Erik from ManualsPlus]]></dc:creator>
		<pubDate>Sun, 21 Dec 2025 09:20:50 +0000</pubDate>
				<category><![CDATA[Hallicrafters]]></category>
		<category><![CDATA[Manuals]]></category>
		<category><![CDATA[BULLETINS]]></category>
		<guid isPermaLink="false">https://www.manualsplus.com/hallicrafters-s-77-s-meter-circuit-service-bulletins-service-manual-pdf/</guid>

					<description><![CDATA[Hallicrafters S-77 S Meter Circuit Service Manual: Troubleshoot and calibrate S-77 meter circuits efficiently. File size: 1.0 MB.]]></description>
										<content:encoded><![CDATA[<p><!-- mpse:generated:start --></p>
<p class="mpse-brief">The service manual for Hallicrafters bulletins provides detailed instructions for installing and calibrating an &quot;S&quot; meter in various Hallicrafters communication receivers, including models S-85, S20R, and SX62. It covers the necessary setup adjustments, such as mechanical and electrical zero settings, and offers troubleshooting tips for issues like inability to obtain electrical zero due to weak tubes or incorrect resistor values.</p>
<ul class="mpse-meta" style="margin:0 0 .75rem 1.2rem;list-style:disc;">
<li><strong>Brand:</strong> Hallicrafters</li>
<li><strong>Model:</strong> BULLETINS</li>
<li><strong>Type:</strong> service manual</li>
<li><strong>File size:</strong> 1.0 MB</li>
</ul>
<h2 id="manual-overview">Manual Overview</h2>
<p>The Hallicrafters service manual provides detailed instructions for installing and calibrating an &#8220;S&#8221; meter in various communication receivers, including models S-85, S20R, SX62, and others. The installation involves measuring the plate current of an RF or IF stage controlled by AVC to indicate signal strength. For optimal performance, the circuit is typically inserted in the plate return of the first RF tube, though it may also be placed in an IF tube&#8217;s plate return. Key conditions include ensuring the stage is AVC-controlled and that the tube&#8217;s screen current does not pass through the meter. Calibration requires setting both mechanical and electrical zero. Mechanical zero is set with the receiver off, aligning the pointer to the scale&#8217;s rightmost mark. Electrical zero involves adjusting the RF gain to maximum, tuning to a quiet frequency, and grounding the antenna terminals to set the meter to zero. Troubleshooting includes checking for weak tubes, incorrect cathode resistor values, and residual AVC voltage. An isolation transformer is recommended for safety when connecting the meter in certain models.</p>
<h3>Quick Issues Covered</h3>
<ul>
<li>Diagnose electrical zero issues in Hallicrafters S-85 receivers.</li>
<li>Calibrate &#039;S&#039; meter using mechanical and electrical zero settings.</li>
<li>Trace &#039;S&#039; meter circuit in Hallicrafters S-77 and S-77A models.</li>
</ul>

<h2 id="overview">Overview</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="specs">Specifications</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="controls">Controls &amp; Indicators</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="setup">Installation / Setup</h2>
<p>The installation of an &#8220;S&#8221; meter in Hallicrafters receivers involves several key steps and considerations. The meter is installed by measuring the plate current of an R.F. or I.F. stage controlled by AVC, as this current varies inversely with signal strength. The circuit is typically inserted in the plate return of the first R.F. tube for best results, though it can also be placed in the I.F. tube&#8217;s plate return. The chosen stage must be controlled by AVC, and the tube&#8217;s screen current must not pass through the meter.</p>
<p>After installation, adjustments are necessary, including setting the mechanical zero with the set turned off and the pointer adjustment screw, and setting the electrical zero with the RF gain at maximum, AVC on, and other controls set as specified. The electrical zero is set by tuning to a quiet spot, grounding the antenna terminals, and adjusting the zero set control. If difficulties arise, variations in the circuit or checking components like the tube or cathode resistor may be needed. An isolation transformer is required for safety in certain installations.</p>
<h2 id="operation">Operation</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="troubleshooting">Troubleshooting &amp; Error Codes</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="safety">Safety &amp; Warnings</h2>
<p>An &#8220;S&#8221; meter installed in certain Hallicrafters receivers requires safety precautions to prevent hazards. Specifically, an isolation transformer (such as the STANCOR type P-6410 or equivalent) must be used because one lead of the meter is connected to B-, which is tied to one side of the AC line. Additionally, the meter terminals must be completely covered, and the connecting lead must be rubber-covered for 115 volts AC.</p>
<div class="manual-preview" style="margin-top:1.5rem;"><iframe src="https://manualsplus.nyc3.digitaloceanspaces.com/wp-content/uploads/2025/12/21092103/Hallicrafters-S-77-S-meter-circuit-Service-bulletins.pdf#toolbar=1&#038;view=FitH" width="100%" height="900" style="border:none;" loading="lazy"></iframe></div>
<p class="mpse-download-bottom" style="margin-top:1rem;"><a class="button button-primary" href="https://manualsplus.nyc3.digitaloceanspaces.com/wp-content/uploads/2025/12/21092103/Hallicrafters-S-77-S-meter-circuit-Service-bulletins.pdf" target="_blank" rel="nofollow noopener">Download BULLETINS Service manual (PDF – 1.0 MB)</a></p>
<p><!-- mpse:generated:end --></p>
<p>Hallicrafters S-77 S Meter Circuit Service Manual: Troubleshoot and calibrate S-77 meter circuits efficiently. File size: 1.0 MB.</p>
<ul>
<li><strong>Brand:</strong> Hallicrafters-s-77-s-meter-circuit-service</li>
<li><strong>Model:</strong> BULLETINS</li>
<li><strong>Type:</strong> Service manual</li>
<li><strong>File size:</strong> 1.0 MB</li>
</ul>
<h2 id="overview">Overview</h2>
<p>Brief overview of the product.</p>
<h2 id="specs">Specifications</h2>
<ul>
<li>Key spec 1</li>
<li>Key spec 2</li>
</ul>
<h2 id="controls">Controls &#038; Indicators</h2>
<p>Control panel/button layout.</p>
<h2 id="setup">Installation / Setup</h2>
<ol>
<li>Step 1…</li>
<li>Step 2…</li>
</ol>
<h2 id="operation">Operation</h2>
<p>Basic usage, modes, cycles.</p>
<h2 id="troubleshooting">Troubleshooting &#038; Error Codes</h2>
<table>
<thead>
<tr>
<th>Issue / Code</th>
<th>Fix</th>
</tr>
</thead>
<tbody>
<tr>
<td>Example</td>
<td>How to fix…</td>
</tr>
</tbody>
</table>
<h2 id="safety">Safety &#038; Warnings</h2>
<ul>
<li>Important warning…</li>
</ul>
<h2 id="downloads">Downloads</h2>
<p><a class="button button-primary" href="https://manualsplus.nyc3.digitaloceanspaces.com/wp-content/uploads/2025/12/21092103/Hallicrafters-S-77-S-meter-circuit-Service-bulletins.pdf" target="_blank" rel="nofollow noopener">Download BULLETINS service manual (PDF)</a></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.manualsplus.com/hallicrafters-s-77-s-meter-circuit-service-bulletins-service-manual-pdf/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Hallicrafters-s-40-40a-40b-s-meter-circuit-service BULLETINS – Service manual (PDF)</title>
		<link>https://www.manualsplus.com/hallicrafters-s-40-40a-40b-s-meter-circuit-service-bulletins-service-manual-pdf/</link>
					<comments>https://www.manualsplus.com/hallicrafters-s-40-40a-40b-s-meter-circuit-service-bulletins-service-manual-pdf/#respond</comments>
		
		<dc:creator><![CDATA[Erik from ManualsPlus]]></dc:creator>
		<pubDate>Sun, 21 Dec 2025 08:56:41 +0000</pubDate>
				<category><![CDATA[Hallicrafters]]></category>
		<category><![CDATA[Manuals]]></category>
		<category><![CDATA[BULLETINS]]></category>
		<guid isPermaLink="false">https://www.manualsplus.com/hallicrafters-s-40-40a-40b-s-meter-circuit-service-bulletins-service-manual-pdf/</guid>

					<description><![CDATA[Service manual for Hallicrafters S-40 series S-meter circuit. Provides troubleshooting and calibration instructions. PDF size: 1.0 MB.]]></description>
										<content:encoded><![CDATA[<p><!-- mpse:generated:start --></p>
<p class="mpse-brief">The service manual for Hallicrafters bulletins provides instructions for installing and calibrating an &quot;S&quot; meter in various Hallicrafters communications receivers, including models S-85, S20R, and SX62. It covers setup procedures, such as mechanical and electrical zero settings, and troubleshooting tips for issues like inability to obtain electrical zero, often due to weak tubes or incorrect resistor values.</p>
<ul class="mpse-meta" style="margin:0 0 .75rem 1.2rem;list-style:disc;">
<li><strong>Brand:</strong> Hallicrafters</li>
<li><strong>Model:</strong> BULLETINS</li>
<li><strong>Type:</strong> service manual</li>
<li><strong>File size:</strong> 1.0 MB</li>
</ul>
<h2 id="manual-overview">Manual Overview</h2>
<p>The Hallicrafters service manual provides detailed instructions for installing and calibrating an &#8220;S&#8221; meter in various receiver models, including the S-85, S20R, and SX62. The &#8220;S&#8221; meter measures the plate current of an RF or IF stage, which inversely correlates with signal strength. For optimal performance, the circuit should be inserted in the plate return of the first RF tube, ensuring the stage is controlled by AVC and the tube&#8217;s screen current does not pass through the meter. Calibration involves setting mechanical and electrical zero points. Mechanical zero is set with the receiver off, adjusting the pointer to the last calibration mark. Electrical zero requires setting the RF gain to maximum, turning off noise limiters, and grounding the antenna terminals. If electrical zero cannot be achieved, potential issues include weak tubes, incorrect cathode resistor values, or residual AVC voltage. An isolation transformer is recommended for safety when connecting the meter to AC lines. The manual also includes specific circuit diagrams and installation instructions for various models.</p>
<h3>Quick Issues Covered</h3>
<ul>
<li>Diagnose electrical zero issues in Hallicrafters S-85 receivers.</li>
<li>Calibrate &#039;S&#039; meter for accurate signal strength readings.</li>
<li>Trace &#039;S&#039; meter circuit schematics for installation guidance.</li>
</ul>

<h2 id="overview">Overview</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="specs">Specifications</h2>
<ul>
<li>1 Meter calibrated in &quot;S&quot; units, 0-5 ma movement (82-283)</li>
<li>1 25-922 control, electrical zero set 500 ohms</li>
<li>1 23X20x820 Resistor 82 ohms 1/2 watt</li>
<li>1 23X20X331 Resistor 330 ohms 1/2 watt</li>
</ul>
<h2 id="controls">Controls &amp; Indicators</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="setup">Installation / Setup</h2>
<p>The installation of an &#8220;S&#8221; meter in Hallicrafters receivers involves several key steps and conditions. The meter circuit is typically inserted in the plate return of the first RF tube, as this stage is generally more sensitive. It is crucial that the stage chosen is controlled by AVC and that the tube&#8217;s screen current does not pass through the meter.</p>
<p>After installation, adjustments are necessary, including setting the mechanical zero by turning the set off and adjusting the pointer to the last calibration mark on the right side of the meter scale. For electrical zero, the RF gain should be set to maximum, AVC on, noise limiter off, BFO off, and the set should be warmed up for at least ten minutes. The antenna should be removed and terminals shorted to ground to set the meter pointer to &#8220;S&#8221; unit zero on the left side of the scale.</p>
<p>If electrical zero is difficult to achieve, potential causes include a weak or aged tube, incorrect cathode resistor value, or residual AVC voltage. In some cases, zeroing with the AVC off or shorting the RF gain control may be necessary. An isolation transformer is required to prevent hazards, especially when B- is connected to one side of the AC line. The meter terminals must be covered, and connecting leads should be rubber-covered 115 volts AC type.</p>
<h2 id="operation">Operation</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="troubleshooting">Troubleshooting &amp; Error Codes</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="safety">Safety &amp; Warnings</h2>
<p>An &#8220;S&#8221; meter installed according to the provided diagrams must have one lead connected to B-, which is connected to one side of the AC line in certain receivers. To prevent hazards, an isolation transformer (such as STANCOR type P-6410 or equivalent) must be used. Additionally, the meter terminals must be completely covered, and the connecting lead must be rubber-covered and suitable for 115 volts AC.</p>
<div class="manual-preview" style="margin-top:1.5rem;"><iframe src="https://manualsplus.nyc3.digitaloceanspaces.com/wp-content/uploads/2025/12/21085655/Hallicrafters-S-40-40A-40B-S-meter-circuit-Service-bulletins.pdf#toolbar=1&#038;view=FitH" width="100%" height="900" style="border:none;" loading="lazy"></iframe></div>
<p class="mpse-download-bottom" style="margin-top:1rem;"><a class="button button-primary" href="https://manualsplus.nyc3.digitaloceanspaces.com/wp-content/uploads/2025/12/21085655/Hallicrafters-S-40-40A-40B-S-meter-circuit-Service-bulletins.pdf" target="_blank" rel="nofollow noopener">Download BULLETINS Service manual (PDF – 1.0 MB)</a></p>
<p><!-- mpse:generated:end --></p>
<p>Service manual for Hallicrafters S-40 series S-meter circuit. Provides troubleshooting and calibration instructions. PDF size: 1.0 MB.</p>
<ul>
<li><strong>Brand:</strong> Hallicrafters-s-40-40a-40b-s-meter-circuit-service</li>
<li><strong>Model:</strong> BULLETINS</li>
<li><strong>Type:</strong> Service manual</li>
<li><strong>File size:</strong> 1.0 MB</li>
</ul>
<h2 id="overview">Overview</h2>
<p>Brief overview of the product.</p>
<h2 id="specs">Specifications</h2>
<ul>
<li>Key spec 1</li>
<li>Key spec 2</li>
</ul>
<h2 id="controls">Controls &#038; Indicators</h2>
<p>Control panel/button layout.</p>
<h2 id="setup">Installation / Setup</h2>
<ol>
<li>Step 1…</li>
<li>Step 2…</li>
</ol>
<h2 id="operation">Operation</h2>
<p>Basic usage, modes, cycles.</p>
<h2 id="troubleshooting">Troubleshooting &#038; Error Codes</h2>
<table>
<thead>
<tr>
<th>Issue / Code</th>
<th>Fix</th>
</tr>
</thead>
<tbody>
<tr>
<td>Example</td>
<td>How to fix…</td>
</tr>
</tbody>
</table>
<h2 id="safety">Safety &#038; Warnings</h2>
<ul>
<li>Important warning…</li>
</ul>
<h2 id="downloads">Downloads</h2>
<p><a class="button button-primary" href="https://manualsplus.nyc3.digitaloceanspaces.com/wp-content/uploads/2025/12/21085655/Hallicrafters-S-40-40A-40B-S-meter-circuit-Service-bulletins.pdf" target="_blank" rel="nofollow noopener">Download BULLETINS service manual (PDF)</a></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.manualsplus.com/hallicrafters-s-40-40a-40b-s-meter-circuit-service-bulletins-service-manual-pdf/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Hallicrafters-s-20r-s-meter-circuit-service BULLETINS – Service manual (PDF)</title>
		<link>https://www.manualsplus.com/hallicrafters-s-20r-s-meter-circuit-service-bulletins-service-manual-pdf/</link>
					<comments>https://www.manualsplus.com/hallicrafters-s-20r-s-meter-circuit-service-bulletins-service-manual-pdf/#respond</comments>
		
		<dc:creator><![CDATA[Erik from ManualsPlus]]></dc:creator>
		<pubDate>Sun, 21 Dec 2025 08:41:25 +0000</pubDate>
				<category><![CDATA[Hallicrafters]]></category>
		<category><![CDATA[Manuals]]></category>
		<category><![CDATA[BULLETINS]]></category>
		<guid isPermaLink="false">https://www.manualsplus.com/hallicrafters-s-20r-s-meter-circuit-service-bulletins-service-manual-pdf/</guid>

					<description><![CDATA[Hallicrafters S-20R S-Meter Circuit Service Manual BULLETINS: Troubleshoot and calibrate S-meter circuits efficiently. File size: 1.0 MB.]]></description>
										<content:encoded><![CDATA[<p><!-- mpse:generated:start --></p>
<p class="mpse-brief">The service manual for Hallicrafters BULLETINS provides instructions for installing an &quot;S&quot; meter circuit in various Hallicrafters models, detailing the setup process, necessary adjustments, and troubleshooting tips. It emphasizes the importance of proper calibration and offers solutions for common issues such as difficulty in obtaining electrical zero and the need for an isolation transformer to prevent hazards.</p>
<ul class="mpse-meta" style="margin:0 0 .75rem 1.2rem;list-style:disc;">
<li><strong>Brand:</strong> Hallicrafters</li>
<li><strong>Model:</strong> BULLETINS</li>
<li><strong>Type:</strong> service manual</li>
<li><strong>File size:</strong> 1.0 MB</li>
</ul>
<h2 id="manual-overview">Manual Overview</h2>
<p>The Hallicrafters service manual provides detailed instructions for installing and calibrating an &#8220;S&#8221; meter in various communications receivers, including models S-85, S20R, S40, and SX62. The manual emphasizes that the meter circuit should be inserted in the plate return of the first RF tube for optimal sensitivity, although it can also be placed in the IF stage. Key conditions for installation include ensuring the stage is controlled by AVC and that the tube&#8217;s screen current does not pass through the meter. Calibration involves setting both mechanical and electrical zero. Mechanical zero is set with the device off, using the pointer adjustment screw. Electrical zero requires the RF gain at maximum, AVC on, and the antenna shorted to ground. If electrical zero is difficult to achieve, potential issues include weak tubes or incorrect cathode resistor values. The manual also provides guidance on using an isolation transformer to prevent hazards when connecting the meter to the AC line.</p>
<h3>Quick Issues Covered</h3>
<ul>
<li>Diagnose inability to obtain electrical zero on &#039;S&#039; meter.</li>
<li>Adjust mechanical and electrical zero settings for calibration.</li>
<li>Trace &#039;S&#039; meter circuit schematics for Hallicrafters S-85 model.</li>
</ul>

<h2 id="overview">Overview</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="specs">Specifications</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="controls">Controls &amp; Indicators</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="setup">Installation / Setup</h2>
<p>The installation of an &#8220;S&#8221; meter in Hallicrafters receivers involves several key steps and considerations. The meter circuit is typically inserted in the plate return of the first RF tube, although it can also be placed in the IF tube plate return. The stage chosen must be controlled by AVC, and the tube&#8217;s screen current must not pass through the meter. After installation, adjustments are necessary, including setting the mechanical zero with the set off and the electrical zero with the RF gain at maximum, AVC on, noise limiter off, and BFO off. The setup should be checked occasionally, especially after long periods of use. An isolation transformer is required for certain models to prevent hazards, and specific components like resistors and controls are included in the kit for proper installation and calibration.</p>
<h2 id="operation">Operation</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="troubleshooting">Troubleshooting &amp; Error Codes</h2>
<p><em>Refer to the PDF for details.</em></p>
<h2 id="safety">Safety &amp; Warnings</h2>
<p>An &#8220;S&#8221; meter installed according to the provided diagrams must have one lead connected to B-, which is connected to one side of the AC line. To prevent hazards, an isolation transformer (such as STANCOR type P-6410 or equivalent) must be used. Additionally, the meter terminals &#8220;A&#8221; must be completely covered, and the connecting lead &#8220;B&#8221; must be the rubber-covered 115 volts AC type.</p>
<div class="manual-preview" style="margin-top:1.5rem;"><iframe src="https://manualsplus.nyc3.digitaloceanspaces.com/wp-content/uploads/2025/12/21084138/Hallicrafters-S-20R-S-meter-circuit-Service-bulletins.pdf#toolbar=1&#038;view=FitH" width="100%" height="900" style="border:none;" loading="lazy"></iframe></div>
<p class="mpse-download-bottom" style="margin-top:1rem;"><a class="button button-primary" href="https://manualsplus.nyc3.digitaloceanspaces.com/wp-content/uploads/2025/12/21084138/Hallicrafters-S-20R-S-meter-circuit-Service-bulletins.pdf" target="_blank" rel="nofollow noopener">Download BULLETINS Service manual (PDF – 1.0 MB)</a></p>
<p><!-- mpse:generated:end --></p>
<p>Hallicrafters S-20R S-Meter Circuit Service Manual BULLETINS: Troubleshoot and calibrate S-meter circuits efficiently. File size: 1.0 MB.</p>
<ul>
<li><strong>Brand:</strong> Hallicrafters-s-20r-s-meter-circuit-service</li>
<li><strong>Model:</strong> BULLETINS</li>
<li><strong>Type:</strong> Service manual</li>
<li><strong>File size:</strong> 1.0 MB</li>
</ul>
<h2 id="overview">Overview</h2>
<p>Brief overview of the product.</p>
<h2 id="specs">Specifications</h2>
<ul>
<li>Key spec 1</li>
<li>Key spec 2</li>
</ul>
<h2 id="controls">Controls &#038; Indicators</h2>
<p>Control panel/button layout.</p>
<h2 id="setup">Installation / Setup</h2>
<ol>
<li>Step 1…</li>
<li>Step 2…</li>
</ol>
<h2 id="operation">Operation</h2>
<p>Basic usage, modes, cycles.</p>
<h2 id="troubleshooting">Troubleshooting &#038; Error Codes</h2>
<table>
<thead>
<tr>
<th>Issue / Code</th>
<th>Fix</th>
</tr>
</thead>
<tbody>
<tr>
<td>Example</td>
<td>How to fix…</td>
</tr>
</tbody>
</table>
<h2 id="safety">Safety &#038; Warnings</h2>
<ul>
<li>Important warning…</li>
</ul>
<h2 id="downloads">Downloads</h2>
<p><a class="button button-primary" href="https://manualsplus.nyc3.digitaloceanspaces.com/wp-content/uploads/2025/12/21084138/Hallicrafters-S-20R-S-meter-circuit-Service-bulletins.pdf" target="_blank" rel="nofollow noopener">Download BULLETINS service manual (PDF)</a></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.manualsplus.com/hallicrafters-s-20r-s-meter-circuit-service-bulletins-service-manual-pdf/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/?utm_source=w3tc&utm_medium=footer_comment&utm_campaign=free_plugin

Page Caching using Disk: Enhanced 

Served from: www.manualsplus.com @ 2026-04-07 14:21:40 by W3 Total Cache
-->