Rohde-schwarz-hm8001-2-operation MANUAL – Operation manual (PDF)

The manual for the HM8001-2 mainframe by HAMEG Instruments, a Rohde & Schwarz company, provides detailed instructions on setup, operation, and troubleshooting, including guidelines for connecting data and signal lines, ensuring proper shielding, and maintaining compliance with electromagnetic compatibility standards. It also covers the modular system's power supply specifications, safety precautions, and procedures for checking the device for any mechanical damage upon unpacking.

  • Brand: Manuals
  • Model: MANUAL
  • Type: operation manual
  • File size: 651.4 KB

Manual Overview

The HM8001-2 mainframe from HAMEG, a Rohde & Schwarz company, is designed for modular system integration, supporting up to two modules with electronic regulation and short-circuit protection. Troubleshooting involves ensuring proper cable shielding and adherence to specified cable lengths to prevent electromagnetic interference. Error diagnostics focus on maintaining signal integrity through the use of double-shielded cables, particularly in environments with strong electromagnetic fields, which may cause minor deviations in measurement accuracy. Calibration and adjustments require attention to power supply specifications, ensuring modules operate within defined voltage limits. The mainframe features stackable units, with up to five units stackable using supplied foot holders to ensure stability. For board-level guidance, the device includes four BNC connectors for signal input/output, with optional modules available for expanded functionality. The unit complies with CE standards for electromagnetic compatibility and safety, with specific guidelines for data and signal cable usage to maintain compliance. Regular maintenance checks for mechanical damage are recommended, especially after transport.

Quick Issues Covered

  • Diagnose power-up failures with module power supply checks.
  • Calibrate using module-specific voltage and current settings.
  • Resolve error codes via rear BNC connections (Option HO801).

Overview

The HM8001-2 is a mainframe product by HAMEG Instruments, a Rohde & Schwarz company, designed as a base unit for the Modular System 8000. It provides power supply for up to two modules, with electronically regulated, floating, and short-circuit-proof DC voltages. The mainframe can stack up to five units and includes options for additional BNC connectors. The manual covers technical data, safety instructions, installation, operation, and maintenance of the HM8001-2, ensuring compliance with CE marking directives and standards for electromagnetic compatibility.

Specifications

  • Mainframe
  • Modular System
  • Basiseinheit für die Einschubmodule vom Modularsystem 8000
  • Stromversorgung für 2 Module
  • Gleichspannungen sind elektronisch geregelt, erdfrei und kurzschlussfest
  • Netztransformator mit Thermosicherung
  • Bis zu 5 Grundgeräte stapelbar
  • Einschubmodul zum Einbau eigener Schaltungen lieferbar
  • 4 BNC-Buchsen auf der Rückseite des HM8001-2 (Option HO801)
  • Modul-Versorgungsspannungen
  • 2×8 Vac mit je 0,5A belastbar
  • 2×5 Vpc mit je 1A belastbar
  • 4×20 Vpc mit je 0,5A belastbar
  • Spannungswerte: zwischen 9 V und 20 V
  • Polarität: beliebig
  • Leistung pro Modul: max. 25 Watt
  • Alle Gleichspannungen sind elektronisch geregelt, massefrei und kurzschlussfest
  • Prüfspannung gegen Masse: 500V
  • Netztaste Ein/Aus zwischen beiden Modulen an der Vorderfront
  • Schutzart: Schutzklasse I (EN 61010-1)
  • Netzspannung: 115/230V bei 50 – 60 Hz
  • Leistungsaufnahme: max. 110 Watt
  • Arbeitstemperatur: +9°C … 40°C
  • Lagertemperatur: -20°C … +70°C
  • max. rel. Luftfeuchtigkeit: 5% … 80% (ohne Kondensation)
  • Maße (B x H x T): 289 x 75 x 369 mm
  • Gewicht: ca. 4 kg

Controls & Indicators

Netztaste Ein/Aus zwischen beiden Modulen an der Vorderfront.

Installation / Setup

The setup of the HM8001-2 mainframe involves several key considerations:

1. Wiring: Data and signal connections must use adequately shielded cables. Data cables should not exceed 3 meters in length and must remain indoors. Signal cables should also be as short as possible and use shielded coaxial cables (RG58/U). For signal generators, double-shielded coaxial cables (RG223/U, RG214/U) are required.

2. Clearances: When stacking the HM8001-2 with other devices, ensure precise alignment using the supplied foot holders. The foot holders should be attached with the provided double-sided tape, and their pegs must fit into the ventilation holes of the device below to prevent slipping.

3. Calibration: No specific calibration instructions are provided.

4. Prerequisites: After unpacking, inspect the device for mechanical damage or loose parts. In case of transport damage, contact the supplier and do not operate the device.

5. Environmental Conditions: The device should be operated within a temperature range of +9°C to +40°C and stored between -20°C and +70°C, with a relative humidity of 5% to 80% without condensation.

6. Electrical Requirements: The device operates at a voltage of 115/230V with a frequency of 50-60 Hz and a maximum power consumption of 110 watts. It is equipped with a power switch located between the two modules on the front panel.

Operation

Refer to the PDF for details.

Troubleshooting & Error Codes

Refer to the PDF for details.

Safety & Warnings

The manual provides the following safety warnings and precautions:

1. Data Connections: The connection of measuring devices or their interfaces with external devices (printers, computers, etc.) should only be made with adequately shielded cables. Unless a shorter maximum cable length is specified in the manual, data cables (input/output, signal/control) should not exceed a length of 3 meters and should not be outside of buildings. If multiple interface cables can be connected to a device interface, only one should be connected at a time. Double-shielded connection cables should generally be used for data cables. The double-shielded cable HZ72 from HAMEG is suitable as an IEEE-Bus cable.

2. Signal Connections: Measuring cables for signal transmission between the measuring point and the measuring device should generally be kept as short as possible. If no shorter length is prescribed, signal cables (input/output, signal/control) should not exceed a length of 3 meters and should not be outside of buildings. All signal cables should fundamentally be used as shielded cables (coaxial cable – RG58/U). For signal generators, double-shielded coaxial cables (RG223/U, RG214/U) must be used.

3. Impact on Devices: In the presence of strong high-frequency electrical or magnetic fields, despite careful measurement setup, unwanted signal components may be introduced into the device through the connected cables and lines. This does not lead to destruction or shutdown of HAMEG devices. However, slight deviations of the display and measurement values beyond the specified specifications may occur in individual cases due to external circumstances.

Download MANUAL Operation manual (PDF – 651.4 KB)

Operation manual for Rohde-Schwarz HM8001-2; assists technicians in troubleshooting and calibrating the device. File size: 651.4 KB.

  • Brand: Rohde-schwarz-hm8001-2-operation
  • Model: MANUAL
  • Type: Operation manual
  • File size: 651.4 KB

Overview

Brief overview of the product.

Specifications

  • Key spec 1
  • Key spec 2

Controls & Indicators

Control panel/button layout.

Installation / Setup

  1. Step 1…
  2. Step 2…

Operation

Basic usage, modes, cycles.

Troubleshooting & Error Codes

Issue / CodeFix
ExampleHow to fix…

Safety & Warnings

  • Important warning…

Downloads

Download MANUAL operation manual (PDF)

Rohde-Schwarz HM8001-2 Operation Manual Overview

The Rohde-Schwarz HM8001-2 is a precision handheld multimeter designed for accurate electrical measurements in various industrial and laboratory environments. This device offers reliable voltage, current, resistance, and continuity testing with high sensitivity and durability, making it an essential tool for technicians and engineers.

Main Features and Specifications

  • Measurement Range: AC/DC Voltage up to 600V, Current up to 10A
  • Resistance Measurement: 0.1 Ω to 40 MΩ
  • Continuity Testing with audible buzzer
  • Backlit LCD display for easy reading in low light conditions
  • Auto-ranging function for quick and accurate measurements
  • Overload protection on all ranges
  • Compact, ergonomic design with durable housing
  • Battery operated with low battery indicator

Basic Usage and Operation Tips

Before use, ensure the device is powered on and the battery is sufficiently charged. Select the desired measurement mode using the rotary switch. Connect the test leads to the appropriate input jacks and then to the circuit or component under test. Always start with the highest measurement range to prevent damage. Use the backlight feature in dim environments for better visibility. After measurements, turn off the device to conserve battery life.

Troubleshooting and Maintenance

If the device does not power on, check and replace the batteries as needed. Ensure test leads are properly connected and not damaged. If readings are unstable or incorrect, verify the calibration status and consider recalibration if necessary. Clean the device regularly with a soft, dry cloth and avoid exposure to moisture or extreme temperatures. Store the multimeter in a protective case when not in use.

Safety Reminder

Always observe proper safety precautions when working with electrical equipment. Do not exceed the specified input limits to avoid electric shock or damage to the device. Use insulated test leads and avoid contact with live circuits. Disconnect power before measuring resistance or continuity. Follow all local electrical safety regulations and guidelines.