Hp-87510a-operation-part 3 – Operation manual (PDF)

The Hp-87510a OPERATION – manual part 3 provides detailed instructions on setting up and operating the device, including configuring various functions such as time stamps, error correction, and channel coupling. It also offers troubleshooting guidance by detailing commands for displaying and adjusting parameters, executing tests, and managing data storage formats.

  • Brand: Hp-87510a-operation-part
  • Model: 3
  • Type: operation manual
  • File size: 6.4 MB

Manual Overview

The HP-87510A operation manual, Part 3, focuses on various operational commands and settings critical for troubleshooting, diagnostics, calibration, and adjustments. It includes detailed instructions on setting error correction functions (CORR), channel coupling (COUC), and port configurations (COouT, DIN, DOUT). The manual provides guidance on executing service tests (EXET) and managing the internal and external trigger modes (EXTTOFF, EXTTON, EXTTPOIN). Calibration adjustments can be made using commands like DEFS for modifying calibration standards and DONE for completing standard calibration measurements. For diagnostics, the manual includes commands to output event status (ESB?) and firmware revisions (FIRR?). Display settings can be adjusted using DISP parameters to select trace types, while DISA parameters manage display allocation modes. The manual also covers file management on flexible and RAM disks using commands like FILC. These instructions are essential for technicians to effectively operate and troubleshoot the HP-87510A system.

Quick Issues Covered

  • Diagnoses external trigger mode issues with EXTT parameter.
  • Calibrates using DEFS for modifying calibration standards.
  • Resolves destructive RAM testing errors with DESTON/OFF.

Overview

Refer to the PDF for details.

Specifications

  • COPT {ON|OFF}
  • CORR {ON|OFF}
  • COUC {ON|OFF}
  • COouT
  • CRED string
  • CURD?
  • DATAM3TER
  • DATAMNONE
  • DATAMTHRU
  • DAYMYEAR
  • DCBUS value
  • DEFS value
  • DELA
  • DELO
  • DELR {1-8}
  • DELRFIXM
  • DESTOFF
  • DESTON
  • DFLT
  • DIN
  • DISA parameter
  • DISAALLB
  • DISAALLI
  • DISABASS
  • DISBLIST
  • DISFDOS
  • DISFLIF
  • DISG {ON|OFF}
  • DISL {1|2}
  • DISP parameter
  • DISLLIST
  • DISMCTSP
  • DISMMD
  • DISMNUM
  • DISMSTEP
  • DISMSTSP
  • DISPDATA
  • DISPDATM
  • DISPDDM
  • DISPDMM
  • DISPMEMO
  • DIST {ON|OFF}
  • DONE
  • DOUT
  • DSKEY
  • DUAC {ON/OFF}
  • ENKEY
  • EDITBINL
  • EDITDONE
  • EDITLIS1
  • EDITLIS2
  • EDITLIST
  • ELED value
  • ENKEY
  • EQUCPARA?
  • EQUCPARS?
  • ESB?
  • ESNB value
  • EXET
  • EXPP
  • EXTRLOCK?
  • EXTT parameter
  • EXTTOFF
  • EXTTON
  • EXTTPOIN
  • FBUS value
  • FILC string1,string2,string3,string4
  • FIRLPNOR
  • FIRLPOPE
  • FIRR?
  • FMT parameter
  • FNDAUTO

Controls & Indicators

Refer to the PDF for details.

Installation / Setup

Refer to the PDF for details.

Operation

The manual provides various commands and settings for operating the device. These include:

1. COPT {ON|OFF}: Toggles the time stamp function.
2. CORR {ON|OFF}: Toggles the error correction function.
3. COUC {ON|OFF}: Toggles the channel coupling of stimulus values.
4. COouT: Sets port C of the 24-bit I/O port to output.
5. CRED string &: Creates a directory in MS-DOS format.
6. CURD?: Outputs the current directory.
7. DATAM3TER: Displays calculated data using a specific equation.
8. DATAMNONE: Displays measurement data without calculation.
9. DATAMTHRU: Displays calculated data using another specific equation.
10. DAYMYEAR: Sets the date display mode to day/month/year.
11. DCBUS value: Selects the DC bus.
12. DEFS value: Defines calibration standards to be modified.
13. DELA: Selects the delay format for measurement.
14. DELO: Turns off delta marker mode.
15. DELR {1-8}: Selects delta reference marker.
16. DELRFIXM: Sets a fixed reference marker.
17. DESTOFF: Turns off destructive RAM testing.
18. DESTON: Turns on destructive RAM testing.
19. DFLT: Resets plotting parameters to default.
20. DIN: Sets port D of the 24-bit I/O port to input.
21. DISA parameter: Selects display allocation mode.
22. DISAALLB: Displays HP Instrument BASIC display only.
23. DISAALLI: Displays measurement graticule only.
24. DISABASS: Displays HP Instrument BASIC status only.
25. DISBLIST: Displays BIN sorting table.
26. DISFDOS: Sets disk format to MS-DOS.
27. DISFLIF: Sets disk format to LIF.
28. DISG {ON|OFF}: Toggles graticule display.
29. DISL {1|2}: Selects list sweep table for display and copy.
30. DISP parameter: Selects display trace type.
31. DISPDATA: Displays measured data trace.
32. DISPDATM: Displays both measured and memory data traces.
33. DISPDDM: Displays trace of measured data divided by memory data.
34. DISPDMM: Displays trace of measured data subtracted from memory data.
35. DISPMEMO: Displays memory data trace.
36. DIST {ON|OFF}: Toggles trace display.
37. DONE: Completes standard calibration measurement.
38. DOUT: Sets D port of the 24-bit I/O port to output.
39. DSKEY: Disables front panel keys and rotary knob.
40. DUAC {ON/OFF}: Selects dual or single channel display.
41. ENKEY: Re-enables front panel keys and rotary knob.
42. EDITBINL: Begins editing BIN sorting table.
43. EDITDONE: Completes frequency list editing for list sweep.
44. EDITLIS1: Selects list 1 for editing.
45. EDITLIS2: Selects list 2 for editing.
46. EDITLIST: Begins editing frequency list.
47. ELED value [s]: Sets electrical delay.
48. EQUCPARA?: Outputs parameters of crystal resonator analysis.
49. EQUCPARS?: Outputs extended parameters of crystal resonator analysis.

Troubleshooting & Error Codes

Refer to the PDF for details.

Safety & Warnings

Refer to the PDF for details.

Download 3 Operation manual (PDF – 6.4 MB)

HP-87510A Model 3 Operation Manual: Guide for technicians on troubleshooting, calibration, and assembly procedures. File size: 6.4 MB.

  • Brand: Hp-87510a-operation-part
  • Model: 3
  • Type: Operation manual
  • File size: 6.4 MB

Overview

Brief overview of the product.

Specifications

  • Key spec 1
  • Key spec 2

Controls & Indicators

Control panel/button layout.

Installation / Setup

  1. Step 1…
  2. Step 2…

Operation

Basic usage, modes, cycles.

Troubleshooting & Error Codes

Issue / CodeFix
ExampleHow to fix…

Safety & Warnings

  • Important warning…

Downloads

Download 3 operation manual (PDF)

HP 87510A Operation Manual – Overview

The HP 87510A is a precision microwave switch matrix designed for automated test systems. It enables reliable routing of microwave signals within complex test setups, supporting high-frequency measurements with minimal signal loss. This device is essential for engineers and technicians working in RF and microwave testing environments, providing seamless control over signal paths to enhance testing efficiency and accuracy.

Main Features and Specifications

  • Frequency range: DC to 18 GHz
  • Low insertion loss for accurate signal transmission
  • High isolation between channels to prevent signal interference
  • Multiple switch configurations for flexible routing
  • Remote control capability via standard interfaces
  • Compact and rugged design suitable for laboratory and field use

Basic Usage and Operation Tips

Before operating the HP 87510A, ensure all connections are secure and the device is properly grounded. Use the front panel or remote interface to configure switch paths according to your test requirements. Always verify the signal routing through the matrix before initiating measurements to avoid signal loss or damage. Regularly update the control software to maintain compatibility and performance.

Troubleshooting and Maintenance Notes

If you encounter unexpected signal attenuation or switching errors, check all cable connections and ensure the device firmware is up to date. Periodically inspect the switch contacts for wear or contamination and clean them using appropriate contact cleaners if necessary. Avoid exposing the device to excessive moisture or dust to prolong its operational life. Consult the manual’s troubleshooting section for detailed diagnostic procedures.

Safety Reminder

Always disconnect power before performing maintenance or cleaning. Operate the HP 87510A within the specified environmental conditions to prevent electrical hazards. Use proper ESD precautions when handling the device to protect sensitive components. Follow all safety guidelines outlined in the manual to ensure safe and reliable operation.