SAFETY CAUTIONS:

PLEASE READ THIS SECTION CAREFULLY BEFORE USING THE APPLIANCE.

  • If you have any concerns regarding your health, consult a doctor before using this appliance.
  • This appliance should NEVER be used by any individual suffering from any physical ailment that would limit the user’s capacity to operate the controls.
  • If the product feels excessively hot, switch off at mains and contact the HoMedics Service Centre.
  • This appliance is designed for personal, nonprofessional use only.
  • Do not run cord under carpeting. Do not cover the cord with throw rugs, runners or similar coverings. Do not route the cord under furniture or appliances. Arrange the cord away from traffic areas where it can be tripped over.
  • Do not tilt or move the personal space cooler while it is in operation. Shut off and remove the plug from the outlet before moving.
  • Always plug the Personal Space Cooler Plus directly into a wall outlet/receptacle. Never use an extension cord.

MAINTENANCE:

Cleaning
Unplug from the mains and use a soft damp cloth to clean the fabric if required. Never saturate the mat or use harsh chemical cleaners. No other maintenance is required.
Storage
Place the appliance in its box or in a safe, dry, cool place. Avoid contact with sharp edges or pointed objects which might cut or puncture the fabric surface. To avoid breakage, DO NOT wrap the power cord around the appliance. DO NOT hang the unit by the cord.

WEEE explanation
This marking indicates that this product should not be disposed of with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling.

PRODUCT FEATURES:

HOMEDICS PAC 35WT EU2 Personal Space Cooler - fig

Indoor Personal Space Cooling
This HoMedics MyChill™ Indoor Personal Space Cooler Plus is designed to reduce the temperature up to 12°F / 6.6°C and has a relaxing cooling effect up to 6 FT / 1.8 M from the front of the unit. The cooling effect increases as the relative humidity decreases. The dryer the surrounding air, the more cooling you get. The higher the relative humidity, the less cooling you get. The personal space cooler is most effective when used in warmer and less humid indoor conditions where the humidity is less than 60%. It is designed for use in the office, dorm room, bedside, kitchen, or anywhere you want to cool your indoor personal space. HoMedics MyChill™ Indoor Personal Space Cooler Plus provides natural and efficient cooling, has low power consumption, no compressor, and does not use any ozone-depleting refrigerants.

HOW TO FILL:

HOMEDICS PAC 35WT EU2 Personal Space Cooler - fig 1

Caution: Before filling the unit with water, unplug the Power Adapter from the wall and from the unit.
Note: Always use two hands to carry the unit.
Personal Space Cooler Location
Place the Personal Space Cooler Plus in the desired location prior to filling with water. The front of the unit should be located within 6 FT /1.8 M of the desired personal cooling zone. We recommend placing a waterproof pad under the unit.

  1. Be sure the cooling cartridge is positioned with the “V-shaped” vents facing upward. Never operate the unit without the cooling cartridge.
    HOMEDICS PAC 35WT EU2 Personal Space Cooler - fig 2
  2. Remove the water tank and turn the tank upside down – remove the tank cap by turning it counterclockwise.
    HOMEDICS PAC 35WT EU2 Personal Space Cooler - fig 3
  3. Fill the water tank with clean, cool (not cold) water. We recommend using distilled water if you live in a hard water area. Never use any additive or place essential oils into the water. Even a few drops will damage the unit.
    HOMEDICS PAC 35WT EU2 Personal Space Cooler - fig 4
  4. Replace the tank cap by turning clockwise until tight. Do not overtighten.
    HOMEDICS PAC 35WT EU2 Personal Space Cooler - fig 8
  5. Place the tank into the MyChill cavity, making sure the tank is firmly seated. Water will begin to transfer into the water reservoir.
    HOMEDICS PAC 35WT EU2 Personal Space Cooler - fig 3
  6. Once the water stops emptying into the water reservoir, remove the water tank and refill following steps 2-5 to fully fill the water tank and reservoir.
    HOMEDICS PAC 35WT EU2 Personal Space Cooler - fig 6
  7. Adjust the front vents up or down to direct the airflow as desired.
    HOMEDICS PAC 35WT EU2 Personal Space Cooler - fig 5
  8. Adjust the front vents up or down to direct the airflow as desired.

HOW TO USE:

Plug the power adapter into the back of the unit and the other end into a household electrical outlet.
Speed Adjustment

  1. Power button to control the on/off function. Press once. Fan motor to start at LOW speed, with LED lit.
  2. Press the button once to adjust the fan speed to LOW, press twice for HIGH speed, pressing again to repeat the function.

Low Water Indicator
This unit is equipped with a low water Refill Indicator. It will flash Red indicates the water tank needs to be refilled. The pump will automatically turn off while the fan continues to run. At this time, please turn the unit off and unplug it to refill the tank. Once a full tank is placed in the unit and the unit is turned back on, the low water indicator is reset and the pump is turned on. The Personal Space Cooler is equipped with a safety device that automatically shuts the unit off when the Top Cover is removed from the water reservoir.

REPLACING THE COOLING CARTRIDGES

HOMEDICS PAC 35WT EU2 Personal Space Cooler - fig 10

Replace the Cooling Cartridge seasonally or after 540 hours of use for optimal performance. The Myhill Personal Space Cooler Plus is equipped with a Replace Cooling Cartridge LED that illuminates Red after 540 hours of use indicating the cooling cartridge needs to be replaced.
To purchase a genuine HoMedics replacement cooling cartridge, Model PP-PAC35FLTR, go to your retailer where you purchased your
Myhill Personal Space Cooler Plus, or visit www.homedics.com.
NOTE: If you live in an area with hard water, it may need to be replaced more frequently. In these instances, you will notice mineral build-up on the cooling cartridge that over time may restrict airflow.

  1. Unplug the Power Adaptor from the wall and from the unit. Remove the water tank from the top housing.
    HOMEDICS PAC 35WT EU2 Personal Space Cooler - fig 11
  2. Press the release buttons on both sides and slowly lift the top cover, allowing time for the water to drain.
    HOMEDICS PAC 35WT EU2 Personal Space Cooler - fig 12
  3. Pour out any excess water remaining in the Water Reservoir, then remove the old Cooling Cartridge and discard.
    HOMEDICS PAC 35WT EU2 Personal Space Cooler - fig 13
  4. Set the new Cooling Cartridge in place. Be sure the Cooling Cartridge is positioned with the “V-shaped” vents upward.
    HOMEDICS PAC 35WT EU2 Personal Space Cooler - fig 17
  5. Replace the Top Cover onto the water reservoir.
    Refill the Water Tank and Reservoir as described in the “How to Fill” section.HOMEDICS PAC 35WT EU2 Personal Space Cooler - fig 7
  6. Plug the Power Adaptor into the back of the unit and the other end into a household electrical outlet to resume operation.
  7. HOMEDICS PAC 35WT EU2 Personal Space Cooler - fig 14e Replace Cooling Cartridge Timer has been reset.
  8. Turn the unit on, then press and hold the Cooling Cartridge Reset Button for 5 seconds. The LED will flash to indicate th

CLEANING AND CARE

CAUTION: Before cleaning the unit, turn power off and unplug the power adapter from the wall and the unit.

  1. To Clean the Tank and Reservoir 
    Remove the water tank from the personal space cooler by lifting it from the main unit. Unscrew the tank cap and rinse inside the tank with clean water. Empty, rinse and dry the tank, tank cap and water reservoir before refilling. To remove any scale or build up, use a 50/50 mixture of white vinegar and lukewarm water to clean the inside of the tank and reservoir as needed
  2. To Clean the Cooling
    Cartridge Rinse with clean water
  3. To Clean the Pump Filter
    Check and clean the pump filter as needed. Remove the pump filter, brush clean with a soft bristle brush (not included) and rinse clean. Dry and re-install.
    NOTE: Never run water over the pump filter while it is installed.
  4. To Clean the Surface 
    Clean the surface of the unit with a clean damp soft cloth as often as needed. Never use detergents, excess water, treated cloths, harsh cleaning agents or sprays.
HOMEDICS PAC 35WT EU2 Personal Space Cooler - fig 18

Storing your personal space cooler: Clean the Tank and Water Reservoir with a 50/50 mixture of white vinegar and water. Wipe the underside of the Top Cover with a soft,  Jamp, cloth. Rinse the Cooling Cartridge with water and allow to air dry. Be sure to rinse thoroughly and let all parts dry completely before packing in the original carton and storing in a cool, dry location.

TROUBLESHOOTING

PROBLEMPOSSIBLE CAUSESOLUTION
No Power• Unit is not plugged in
• No power at the unit
• Top cover not seated properly
• Plug unit in
• Press the Power Button to turn the unit on
• Check circuits and fuses or try a different outlet
• Remove top cover and re-seat
Peculiar Odor• Cooling cartridge is new
• Unit may have a dirty tank or water
reservoir
• Water in tank or reservoir may be old
• The cooling cartridge may emit a slight odor which will dissipate after a few days
• Follow instructions described in the Cleaning and Care Section
Discoloration of water in the reservoirThe cooling cartridge may emit a slight odor which will dissipate after a few days
• Follow instructions described in the Cleaning and Care Section
• Discoloration will dissipate after a few days of
operation
Replace cooling cartridge LED is illuminated after cooling cartridge replacementHard water used• Use distilled water
Not cooling• Out of the water
• Outside of the recommended cooling zone
• Cool ambient temperature and /or high humidity conditions
• Pump filter clogged
• Refill water tank
• Use within 4 FT / 1.2 M of the unit’s front grill
• Use in warmer and/or less humid conditions
• Clean pump filter as instructed in the Cleaning and Care Section
Replace cooling cartridge LED
is illuminated after cooling
cartridge replacement
• Cooling cartridge reset button not activated• Turn the unit on, then press and hold the cooling
cartridge reset button for 5-seconds until the LED
flashes