The manual for BK Precision's power supplies covers setup and operation, detailing features such as multi-range operation, high programming resolution, and various interfaces for remote control. It also addresses troubleshooting with extensive protection features like overvoltage, overcurrent, and overtemperature protection, ensuring safe and efficient use of the equipment.
Manual Overview
The Bk Precision catalog provides detailed information on various programmable DC power supplies, emphasizing troubleshooting, error diagnostics, calibration, and board-level guidance. The PVS Series offers high power density in a compact 2U package, suitable for applications like motor and inverter testing, with features such as fast transient response and extensive protection modes including OVP, OCP, and OTP. The 9115 Series, with multi-range operation, allows for flexible voltage and current combinations, featuring overvoltage, overpower, and overtemperature protection. The 9200 Series includes multi-range operation and remote control interfaces, supporting SCPI commands for enhanced functionality. Calibration and adjustments are facilitated through high programming and readback resolution, with specific models offering sequence programming and analog interfaces for control and monitoring. Error codes and diagnostics are managed through standard interfaces like USB, RS232, and GPIB, ensuring compatibility with remote monitoring systems. The catalog emphasizes the importance of proper configuration and usage to maintain optimal performance and reliability of the power supplies.
Quick Issues Covered
- Diagnose power-up failures with extensive protection features: OVP, OCP, OTP.
- Calibrate using high programming and readback resolution for precise adjustments.
- Identify error codes via SCPI commands through USB, RS232, GPIB interfaces.
Overview
The PVS Series is a line of high power programmable DC power supplies that deliver up to 5.1 kW of output power. They are designed for bench use, ATE systems integration, R&D, design verification, production testing, and high voltage testing. The series features a compact 2U package, fast transient response time, low noise, and supports standard interfaces like USB, RS232, GPIB, and LAN for remote control. The PVS Series is particularly suitable for motor and inverter testing and can be used for solar array testing with optional SAS software.
Specifications
- Compact, high power density, 2U package
- Convenient single-phase AC input configuration
- Programmable output power up to 5.1 kW
- Fast transient response time of < 0.5 ms
- Standard USB (virtual COM), RS232, GPIB, and LAN interfaces supporting SCPI commands
- External analog programming and monitoring interface
- Extensive protection features: OVP, OCP, OPP, OTP, foldback protection mode, and key-lock function
- Model PVS60085: Voltage 600 V, Current 8.5 A, Power 5100 W
- Model PVS60085MR: Power 3000 W
- Model PVS10005: Voltage 1000 V, Power 5000 W
- Load Regulation Voltage: 60 mV, 100 mV
- Load Regulation Current: 8.5 mA, 5 mA
- Ripple & Noise Voltage: 100 mVrms / 500 mVpp, < 100 mVrms / < 600 mVpp
- Ripple & Noise Current: 15 mA, 10 mA
- Programming Accuracy Voltage: 400 mV, 700 mV
- Programming Accuracy Current: 0.03% + 3.5 mA, 0.03% + 2 mA
- Dimensions (W x H x D): 420 mm x 88 mm x 532 mm
- Weight: 14.6 kg
Controls & Indicators
Refer to the PDF for details.
Installation / Setup
Refer to the PDF for details.
Operation
Refer to the PDF for details.
Troubleshooting & Error Codes
Refer to the PDF for details.
Safety & Warnings
Refer to the PDF for details.
Download CATALOG Manual (PDF – 2.1 MB)
Bk-precision-0-2015-bk-precision CATALOG manual aids technicians in identifying and selecting the correct equipment and parts.
- Brand: Bk-precision-0-2015-bk-precision
- Model: CATALOG
- Type: Manual
- File size: 2.1 MB
Overview
Brief overview of the product.
Specifications
- Key spec 1
- Key spec 2
Controls & Indicators
Control panel/button layout.
Installation / Setup
- Step 1…
- Step 2…
Operation
Basic usage, modes, cycles.
Troubleshooting & Error Codes
| Issue / Code | Fix |
|---|---|
| Example | How to fix… |
Safety & Warnings
- Important warning…
Downloads
Bk-precision-0-2015-bk-precision CATALOG – Manual Overview
The Bk-precision-0-2015-bk-precision is a versatile and reliable piece of test equipment designed for precision measurement and calibration tasks in electrical and electronic applications. This model, identified as -0-2015-, offers a comprehensive catalog of instruments suitable for both professional technicians and hobbyists, enabling accurate diagnostics and performance verification of various devices.
Main Features and Specifications
- Wide range of measurement functions including voltage, current, resistance, and frequency
- High accuracy and resolution for precise readings
- Robust build quality ensuring durability in industrial environments
- Clear digital display with backlight for easy reading in low-light conditions
- Compact and portable design for convenient field use
- Multiple input protection mechanisms to prevent damage from overloads
- Battery-powered operation with low battery indicator
Basic Usage and Operation Tips
Before using the device, ensure the batteries are fully charged or replaced to avoid inaccurate readings. Connect the test leads securely to the appropriate terminals based on the measurement type. Always start with the highest measurement range to prevent overload, then adjust downward for more precise values. Use the hold function to freeze readings when needed. Refer to the manual for detailed instructions on selecting measurement modes and interpreting results.
Troubleshooting and Maintenance
If the device fails to power on, check the battery condition and replace if necessary. In case of erratic or unstable readings, inspect the test leads for damage or poor connections. Clean the device regularly with a soft, dry cloth and avoid exposure to moisture or extreme temperatures. For persistent issues, consult the service section of the manual or contact authorized Bk-precision support.
Safety Reminder
Always observe standard electrical safety precautions when using the Bk-precision-0-2015-bk-precision. Avoid contact with live circuits and ensure the device is rated for the voltage levels being tested. Use insulated test leads and wear appropriate personal protective equipment. Disconnect power before connecting or disconnecting test leads to prevent electric shock or equipment damage.