The Wavetek SSI-3000B service manual provides detailed instructions on setting up, operating, and troubleshooting the service monitor, including specifications for frequency ranges, modulation measurements, and power requirements. It also covers environmental considerations, such as operating temperature limits and the use of an optional inverter for DC power operation.
Overview
The source provides detailed technical specifications and operational instructions for a precision test equipment model, the SSI-3000B. It is designed for both laboratory and field use, highlighting its portability and ruggedness. The manual includes information on frequency range, modulation modes, instrument functions, and power requirements, among other technical details. It also provides guidance on unpacking, inspection, and installation procedures, emphasizing the importance of proper environmental conditions for optimal performance.
Specifications
- Accuracy +5% of full scale
- External Input 100 mVRMS for 5 kHz peak (nominal)
- Burst 0.03 to 1.0 seconds continuously variable
- Depth 0 to 90%
- Bandwidth, 3 dB 10 Hz to 10 kHz
- Accuracy at 30% +5% of full scale
- External Input 100 mVRMS for 100% (nominal)
- Range 400 kHz to 999.9999 MHz
- Resolution 100 Hz
- Display 7 lever/indicator switches plus frequency error counter
- Accuracy See Time Base
- Sensitivity 2 pV for 12 dB SINAD (typical)
- Bandwidth, 3 dB, nominal Narrow 7 kHz
- Wide 50 kHz
- Deviation 0 to +18 kHz
- Ranges 1.8, 6 and 18 kHz
- Bandwidth, 3 dB 0 to 10 kHz (METER response limited to > 10 Hz)
- Accuracy +5% of full scale
- Display METER and CRT
- FM Markers +600 Hz and +5 kHz (accuracy of +5 kHz is +2%)
- Depth 0 to 100%
- Bandwidth, 3 dB 50 Hz to 10 kHz
- Ranges 1.8, 6, and 18% (X10)
- Accuracy at 30% +5% of full scale
- Display METER and CRT
- Display 4 digit LCD, backlighted
- Accuracy Time Base + 1 count
- Gate Period 1.0 second
- Frequency Error + (.01 to 20 kHz) 10.0 Hz
- Modulation 60 to 9,999 Hz 1.0 Hz
- Subtone (RCV) 60 to 250 Hz 0.1 Hz
- External Counter 250 to 9,999 Hz 1.0 Hz
- Lissajous (RCV) 10 to 9,999 Hz 0.01, 0.1, and 1 Hz
- Sweep Width 0 to +18 kHz
- Repetition Time 0.01, 0.1, 1, and 10 msec
- Built-in speaker provides audible indication of frequency range.
- 3-inch speaker with volume control (2 W output).
- External microphone "push-to-talk" switch activates generator output.
- Pre-emphasis and 5 kHz limiter simulates transmitter operation.
- Meter Range 1 to 10 watts (x.1)
- 1 to 100 watts (x1)
- Accuracy +(7% of reading + 3% of full scale) (to 500 MHz)
- Notch Frequency 1 kHz
- Range 0 to 30 dB
- Accuracy, 12 dB + 1dB
- Input Impedance 100 kohm (nominal)
- Input Connector BNC (AUDIO IN)
- Display METER and CRT
- Frequency Range 10 to 9,999 Hz
- Resolution 0.01, 0.1, and 1 Hz
- Accuracy See Time Base
- Display 4 digit lever/indicator switches
- Output 0 to 1 VRMS
- Impedance 600 ohm (nominal)
- Frequency 1 kHz
- Accuracy See Time Base
- Output 0 to 1 VRMS
- Imped
Controls & Indicators
The source does not provide specific information about the front-panel controls or indicators.
Installation / Setup
The source does not provide specific information on installation or setup highlights, including wiring, clearances, calibration, or prerequisites.
Operation
Refer to the PDF for details.
Troubleshooting & Error Codes
Refer to the PDF for details.
Safety & Warnings
Refer to the PDF for details.
Download MANUAL Service manual (PDF – 11.6 MB)
Wavetek SSI 3000B Service Monitor Manual: Troubleshoot, calibrate, and service the Wavetek SSI 3000B efficiently. File size: 11.6 MB.
- Brand: Wavetek-ssi-3000b-service-monitor-operation-service
- Model: MANUAL
- Type: Service manual
- File size: 11.6 MB
Overview
Brief overview of the product.
Specifications
- Key spec 1
- Key spec 2
Controls & Indicators
Control panel/button layout.
Installation / Setup
- Step 1…
- Step 2…
Operation
Basic usage, modes, cycles.
Troubleshooting & Error Codes
| Issue / Code | Fix |
|---|---|
| Example | How to fix… |
Safety & Warnings
- Important warning…
Downloads
Download MANUAL service manual (PDF)