Sencore Tech Tips 117 Testing HV Circuits with the VA62A (PDF)

The manual for the VA62A covers the setup and operation of testing high voltage circuits, specifically focusing on how to dynamically test Integrated High Voltage Transformers (IHVTs) and HV multipliers by simulating actual circuit conditions to check for issues like open or shorted windings. It also provides troubleshooting guidance, including using the RINGING TEST to isolate failures and ensuring proper connections and settings when performing tests to prevent loading of the high impedance secondary circuit.

  • Brand: Sencore
  • Type: manual
  • File size: 500.9 KB

Manual Overview

The Sencore Tech Tips manual #117 provides guidance on testing high voltage (HV) circuits using the VA62A, focusing on troubleshooting, diagnostics, and calibration. It explains the use of the VA62A to dynamically test Integrated High Voltage Transformers (IHVTs) and HV multipliers for defects like open or shorted windings and faulty diodes. The manual emphasizes the importance of using the RINGING TEST to identify winding issues before proceeding with further tests. For IHVTs, the manual details the process of driving the primary with the VA62A and measuring the output voltage to assess the secondary and diode integrity. It highlights the need to compare measured voltages against reference values in a provided table to determine component health. The document also covers testing HV multipliers and focus taps, ensuring correct connections and polarity for accurate results. Safety precautions, such as discharging high voltage circuits before testing, are stressed to prevent hazards.

Quick Issues Covered

  • Diagnose IHVT/HV multiplier faults using VA62A dynamic testing.
  • Use VA62A RINGING TEST to identify shorted or open windings.
  • Refer to schematics for IHVT pin connections and voltage levels.

Safety & Warnings

Before working in the high voltage circuit, discharge the high voltage to chassis ground. Newer receivers do not contain bleeder resistance in the CRT high voltage circuit, and dangerous voltage levels may remain for a substantial period of time after the receiver is turned off.

Download PDF (500.9 KB)

Leave a Comment