The Heathkit manual for the EUW-15 Power Supply provides detailed instructions for setup, operation, and troubleshooting, including specifications for voltage outputs, regulation, and controls such as the divider-regulator switch and voltage adjustment. It also includes information on the internal components like the tube complement and the schematic for proper wiring and voltage measurement.
Manual Overview
The Heathkit SCHEMATICS manual provides detailed guidance on troubleshooting, diagnostics, and adjustments for the EUW-15 Power Supply. For troubleshooting, the manual emphasizes checking the power supply’s output voltages and ensuring they fall within specified ranges: 200 to 350 volts DC for B+ and 6.3 volts AC for filament voltage. Error codes are not explicitly detailed, but diagnostics involve measuring voltage variations and ensuring they remain within 1% from no load to full load at 300 volts. Calibration involves setting the regulator for a 300 V output with no load and using an 11 megohm input VTVM for accurate voltage readings. Board-level guidance includes confirming resistor and capacitor values, with all resistors being 1/2 watt unless specified otherwise. The manual also highlights the importance of using the correct fuses and ensuring proper connections, especially when using the voltage divider as a variable load. Adjustments are made using the REGULATOR VOLTAGE control and various switches, such as the DIVIDER-REGULATOR and PRIMARY VOLTAGE switches.
Quick Issues Covered
- Diagnose power-up failures with voltage-doubler operation checks.
- Calibrate B+ voltage output for less than 1% variation.
- Trace circuit issues using detailed schematic diagrams.
Specifications
- B+ Voltage Output: 200 to 350 volts DC regulated, at 0 to 100 milliamperes continuous
- Filament Voltage Output: 6.3 volts AC at 3 amperes
- B+ Regulation: Output variation less than 1% from no load to full load at 300 volts, Output variation less than +1 volt for a +10 volt variation in the AC line input, Less than 10 millivolts rms ripple, jitter, and noise
- B+ Output Impedance: Less than 10 ohms from 5-100,000 cps
- Divider Voltages (Unregulated): Approximately 500, 400, 300, 200, and 100 volts
- Voltage Divider: Internal, using five 1500 ohm 10 watt resistors; also can be used as a variable internal load
- Variable Load: Voltage divider can be connected as a variable load, but current must not exceed 80 milliamperes
- Tube Complement: 1 – 6L6GC, series regulator, 1 – 6BH6, control amplifier, 1 – OB2, voltage regulator
- Controls And Switches: DIVIDER VOLTAGE (or variable load switch), DIVIDER-REGULATOR switch, REGULATOR VOLTAGE (MIN-MAX) control, POWER (ON-OFF) switch, HIGH VOLTAGE (ON-OFF) switch, PRIMARY VOLTAGE SWITCH (on the chassis)
- Output Terminals: DC+ and DC-, FILament (6.3 VAC), Meter, Chassis ground
Controls & Indicators
The front-panel controls/indicators present are:
– DIVIDER VOLTAGE (or variable load switch)
– DIVIDER-REGULATOR switch
– REGULATOR VOLTAGE (MIN-MAX) control
– POWER (ON-OFF) switch
– HIGH VOLTAGE (ON-OFF) switch
– PRIMARY VOLTAGE SWITCH (on the chassis)