The Heathkit Audio Analyzer Model AA-1 manual provides detailed instructions for assembling, operating, and troubleshooting the device, which combines the functions of an audio wattmeter, high sensitivity AC VTVM, and intermodulation analyzer. It includes specifications on frequency response, sensitivity, range, input and output impedance, and accuracy, ensuring users can effectively analyze audio equipment performance.
Manual Overview
The Heathkit Audio Analyzer Model AA-1 manual provides detailed instructions for assembly, operation, and troubleshooting of the device, which integrates the functions of an audio wattmeter, a high sensitivity AC VTVM, and an intermodulation analyzer. The manual emphasizes the importance of careful assembly to ensure stable and trouble-free operation. For troubleshooting, the manual provides a flowchart to diagnose common issues, with specific attention to error codes and diagnostics. Calibration and adjustments are crucial for maintaining accuracy, with guidelines provided for setting the device to within 5% of full scale for the AC VTVM and wattmeter, and within 10% for the intermodulation analyzer. Board-level guidance includes detailed descriptions of resistor and capacitor color codes, essential for identifying components during assembly and troubleshooting. The manual also specifies the tube complement and power requirements, ensuring technicians can maintain and repair the device effectively.
Quick Issues Covered
- Diagnose power-up failures with transformer and rectifier checks.
- Calibrate using internal generator frequencies: 60 cycles, ~6 kc.
- Adjust sensitivity: AC VTVM at 10 millivolts full scale maximum.
Overview
The Heathkit Audio Analyzer model AA-1 is an instrument that combines the functions of an audio wattmeter, a high sensitivity AC VTVM, and an intermodulation analyzer. It is designed to provide maximum performance, flexibility, and utility at a low cost. The manual emphasizes the importance of careful construction for stable and trouble-free service.
Specifications
- Frequency Response:
- AC VTVM: 10 cycles to 100 kc +1 db.
- Wattmeter: 10 cycles to 50 kc 21 db.
- IM. Analyzer High Pass Filter: 2000 cps to 12000 cps.
- IM. Analyzer Low Pass Filter: 10 cps to 600 cps.
- Sensitivity:
- AC VTVM: 10 millivolts full scale maximum.
- Wattmeter: 15 milliwatts full scale maximum.
- LM. Analyzer: 4 volts minimum high frequency signal required or .17 volts of LF and HF energy mixed 4:1.
- Range:
- AC VIVM: .01, .03, .1, .3, 1, 3, 10, 30, 100, 300 volts RMS full scale.
- DBM: -40, -30, -20, -10, 0, +10, +20, +30, +40, +50 reads from -65 to +52 dbm.
- Wattmeter: 15mw, 1.5 mw, 15 mw, 150 mw, 1.5 w, 15 w, 150 w full scale. Maximum continuous power 25 watts, intermittent power to 50 watts.
- LM. Analyzer: 1%, 3%, 10%, 30%, 100% full scale.
- Input Impedance:
- AC VTVM: 1 megohm or 4, 8, 16 or 6002, switch selected.
- LM. Analyzer: 1 megohm or 4, 8, 16 or 600Q, switch selected.
- Wattmeter: 4, 8, 16 or 600 Q internal load, 10,000 2 across external load.
- Output Impedance:
- Low and High Frequency Output: 3000 2 (600 2 when shunted with 7502 resistor).
- Internal Generator Frequencies:
- Low Frequency: 60 cycles.
- High Frequency: Approximately 6 kc.
- Accuracy:
- AC VTVM and Wattmeter: Within 5% of full scale.
- ILM. Analyzer: Within 10% of full scale.
- General:
- Multipliers: Precision type.
- Meter: 4 1/2" streamlined case with 200 microampere movement.
- Meter Rectifier: Germanium diode bridge.
- Tube Complement: 1 – 12AT7, 1 – 12AU7, 1 – 12AX7, 1 – 6C4, 1 – 6X4.
- Power Supply: Transformer, full wave rectifier.
- Power Requirements: 105-125 volts 50/60 cycles 20 watts.
- Dimensions: 13" wide x 8 1/2" high x 7" deep.
- Net Weight: 9 lbs.
- Shipping Weight: 13 lbs.