Hammarlund SCR-704-1948 Instruction and Service Manual (PDF)

The service manual for Hammarlund radio receivers and power supply units provides detailed instructions for installation, operation, and troubleshooting of models BC-779-A, -B; BC-794-A, -B; BC-1004-B, -C, -D; and R-129/U, as well as power supply units RA-74-B, -C; RA-84-A, -B; and RA-94-A. It includes sections on preventive maintenance techniques, equipment performance checklists, and repair instructions, emphasizing safety precautions due to high voltage risks.

  • Brand: Hammarlund
  • Model: SCR-704-1948
  • Type: service manual
  • File size: 13.8 MB

Manual Overview

The Hammarlund service manual provides detailed guidance for the maintenance and repair of various radio receivers and power supply units, including models BC-779, BC-794, BC-1004, and R-129/U. The manual emphasizes a structured troubleshooting flow, starting with identifying symptoms and using diagnostic techniques to isolate faults. It includes a comprehensive list of error codes and diagnostic procedures to assist technicians in pinpointing issues efficiently. Calibration and adjustment instructions are provided to ensure optimal performance, with specific steps for aligning components and adjusting settings to meet operational standards. The manual also offers board-level guidance, detailing the replacement and repair of circuit boards and components. Safety precautions are highlighted, particularly regarding high voltage areas, with instructions on safe handling and emergency procedures in case of electric shock. The manual serves as a critical resource for technicians, ensuring the effective maintenance and repair of these radio systems.

Quick Issues Covered

  • Diagnose power-up failures in BC-779-A and BC-1004 models.
  • Error codes for alignment issues in SCR-244-A radio sets.
  • Schematics for circuit tracing in RA-74-B power supply units.

Overview

This technical manual, TM 11-866, is published by the Department of the Army and covers radio receivers, power supply units, and radio sets, including models BC-779-A, -B; BC-794-A, -B; BC-1004-B, -C, -D; and R-129/U, as well as power supply units RA-74-B, -C; RA-84-A, -B; and RA-94-A. It also includes radio sets SCR-244-A, -B; SCR-704; and AN/FRR-4 (Hammarlund Super Pro Receiver). The manual provides information and guidance on these products, including their description, installation, operating instructions, maintenance instructions, and repair instructions. It also includes safety warnings regarding high voltage and instructions for the destruction of equipment to prevent enemy use.

Safety & Warnings

The manual includes several safety warnings and precautions:

1. High Voltage Warning: The equipment operates with high voltage, which can be fatal upon contact if safety precautions are not observed.

2. Power Supply Unit Precaution: When working on the power supply unit with the bottom plate off, be cautious of d-c voltages over 400 volts and a-c potentials up to 900 volts, as these are life-threatening.

3. Receiver Precaution: With the dust cover and bottom plate removed, voltages up to 250 volts are exposed on top of the chassis, and up to 400 volts underneath. Service checks inside the set must be done with high voltage on, and it is advised to have another person present who can render aid. Keep one hand in your pocket to prevent touching the circuit with more than one body part.

4. Audio-Frequency Voltage Warning: Audio-frequency voltages up to 150 volts may be present at the 600-ohm SPKR terminals. Turn the AUDIO GAIN control to 0 before touching these terminals.

5. Connector Cable Terminal Strips Warning: Do not remove the sheet metal covers from the connector cable terminal strips without first detaching the plug from the a-c power line or disconnecting the batteries. Simply turning the OFF-ON switch to OFF is not sufficient.

6. Electric Shock Response: In case of electric shock, shut off the high voltage immediately and ground the circuits. If this is not possible, free the victim from contact using a dry board, dry clothing, or other nonconductor, and avoid direct contact with the victim or live conductor. Use extreme caution to avoid electric flash if cutting the high-voltage wire.

7. Symptoms of Electric Shock: Breathing may stop abruptly if the current affects the breathing center at the brain’s base. The victim may appear very white or blue, with a weak or absent pulse, and complete unconsciousness. Burns and body rigidity may occur.

8. Resuscitation Instructions: Provide artificial respiration if breathing stops. Lay the victim prone, clear the mouth of foreign bodies, and ensure the tongue remains extended. Loosen tight clothing and keep the victim warm. The resuscitating operator should straddle the victim’s thighs and apply pressure correctly on the victim’s back to facilitate breathing.

Download PDF (13.8 MB)

Leave a Comment