The Hammarlund manual provides detailed instructions for installing and operating a fixed frequency crystal oscillator in HQ-145, HQ-170, and HQ-180 series receivers, including the necessary tools, parts, and wiring procedures. It also covers troubleshooting steps, such as checking wiring and soldering joints for bad connections and ensuring proper component placement.
Manual Overview
The Hammarlund service manual for the fixed frequency crystal oscillator installation kit provides detailed instructions for integrating the oscillator into HQ-145, HQ-170, and HQ-180 series receivers. The manual emphasizes the importance of precise wiring and component placement to ensure proper operation. For troubleshooting, technicians are advised to verify all wiring connections, solder joints, and component placements against the provided schematic diagrams. The manual does not specify error codes or diagnostics but stresses careful inspection to prevent shorts or poor connections. Calibration involves using the variable capacitor C201 for exact frequency netting. Board-level guidance includes specific steps for connecting wires and components, such as relays and resistors, to designated lugs and pins on the receiver’s chassis. The installation process requires specific tools, including hex nut drivers and a soldering iron, and involves detailed steps for mounting and wiring the crystal oscillator sub-chassis and associated components.
Quick Issues Covered
- Diagnose relay K201 issues in HQ-145, HQ-170, HQ-180 receivers.
- Calibrate frequency using variable capacitor C201 on front panel.
- Trace circuit using schematic diagram, figure #5, for wiring checks.
Overview
Hammarlund provides an eleven position crystal oscillator assembly for the HQ-145, HQ-170, and HQ-180 series receivers. This unit is designed to be installed in the space allocated for the 24-hour clock timer. The oscillator uses a 6CW4 nuvistor and a relay to switch between variable frequency tuning and fixed frequency crystal control. The assembly includes a variable capacitor for precise frequency tuning and allows for easy access to six crystals on the front panel, with five additional crystals located inside the cabinet for less frequently changed channels. The manual covers installation procedures, required tools, and wiring instructions for different receiver series.
Controls & Indicators
The front-panel controls of the fixed frequency crystal oscillator assembly include a variable capacitor (C201) for exact frequency netting and a VFO/xtal knob for selecting normal variable frequency tuning or one of eleven fixed frequencies. Six crystals are accessible on the front panel, while five are located behind the panel.
Installation / Setup
The installation of the fixed frequency crystal oscillator field installation kit requires specific tools such as hollow shaft hex nut drivers, long nose pliers, a small soldering iron, and screwdrivers. The kit includes a crystal oscillator sub-chassis, a relay, knobs, a bracket, a hex nut, a soldering lug, wires, a resistor, a dial plate, and sleeving. The installation involves removing the set from the cabinet, mounting the crystal oscillator sub-chassis and dial plate, and connecting various wires and components as per the detailed wiring instructions for different receiver models. The process also includes checking all wiring and soldering joints for proper connections.
Operation
The operation of the fixed frequency crystal oscillator involves selecting the desired crystal position using the VFO/xtal switch, turning the band switch to the desired band, and tuning the main dial to the approximate frequency while adjusting for maximum “S” meter indication. The variable tuning knob is available for more accurate frequency netting if needed.