The service manual for the Hallicrafters Model SX-71 covers troubleshooting issues related to sudden decreases in sensitivity, which may be caused by leakage between circuits, gassy tubes, or intermittent condensers. It also provides guidelines for detecting and remedying these issues, including checking leakage resistance and addressing intermittent shorts in the oscillator coil.
Manual Overview
The Hallicrafters SX-71 service manual provides detailed troubleshooting procedures for addressing a sudden decrease in sensitivity, a common issue in this model. The manual identifies potential causes such as leakage between the B+ and A.V.C. circuits across IF transformers T-7 or T-8, gassy RF or IF amplifier tubes, intermittent 220 mmfd condensers, and shorts in oscillator coil T-21. Technicians are advised to measure leakage resistance between transformer terminals, ensuring it exceeds 15,000 megohms. If leakage is detected, replacement or adjustment of components like resistor R-41 may be necessary. The manual also highlights the importance of replacing older 6BA6 tubes prone to grid emission. For intermittent performance on Bands 3 to 5, technicians should inspect the oscillator coil T-21 for shorts and apply coil dope after resoldering. Calibration and adjustments must align with Institute of Radio Engineers standards, ensuring optimal receiver performance.
Quick Issues Covered
- Diagnose SX-71 sensitivity loss due to IF transformer leakage.
- Check for gassy RF/IF tubes causing performance issues.
- Trace circuit with schematics to identify oscillator coil shorts.
Specifications
- FREQUENCY LIMITS ON EACH BAND
- Band – 1 .538 mc to 1.65 me
- Band – 2 – 16 me to 4.8 me
- Band – 3 – 4.8 me to 13.5 me
- Band – 4 – 12.5 me to 35 me
- Band – 5 – 46.0 me to 56 mc
- OVERALL BANDWIDTHS
- At the IF frequency of 2075 kc, bandwidth at 6 DB down is 3.5 kc, at 60 DB – 14 kc
- At the IF frequency of 2075 kc (Broad Xtal) 6 DB down is .7 kc, at 60 DB – 11 kc
- At the RF frequency of 1000 kc (Reception Normal) bandwidth at 6 DB down is 3.2 kc and at 60 DB down is 13 kc
- AUDIO RESPONSE
- Plus or minus 5 DB from 100 to 3000 cycles
- IF AMPLIFIER GAIN (155 kc) AND BANDWIDTH
- Gain 15 x 89 x 4.5 x 24%
- At 6 DB down 6 kc 8 kc 8 kc 20 kc
- At 20 DB down 15 kc 16 kc 15 kc 125 kc
- NOISE
- For 2 microvolts input, the signal to noise ratio is not less than 10 DB
- GENERAL SINGLE STAGE PERFORMANCE CHARACTERISTICS
- Band MC uv Ratio Gain RF Gain Gain
- 1 600 13 24,000 x 38.4% 2.9% 14%
- 1.000 6.5 7,000 x 3.5 x 3.5 x 13k
- 1.500 5.3 1,800 x 3.6 x 3.5 x 12k
- 2 18 1.5 28,000
- 4.9% 6.1% 18k
- 3.2 1,000 x
- 4.0 300 x 17k 12k
- 3.5.2 24 8,800 x 1.9% 17k 10%
- 90 14 2,500 x 2.9% 7.6% 12%
- 12.0 570 x 3.3% 11k 12%
Troubleshooting & Error Codes
The troubleshooting guidance for the Model SX-71 receivers addresses a sudden decrease in sensitivity, which can be caused by several issues:
1. Leakage between the BA and A.V.C. circuits across the terminal boards of IF transformers T-7 or T-8.
2. Gassy RF or IF amplifier tubes.
3. Intermittent 220 mmfd condensers connected across IF transformer windings.
4. Intermittent short in oscillator coil T-21, affecting operation on Bands 3 to 5.
To detect leakage across the bakelite terminal boards of the IF transformers, the leakage resistance between the primary and secondary terminals should be greater than 15,000 megohms when all leads are disconnected. A reading of 0.2 volts or less indicates acceptable leakage. If the reading is under 0.2 volts, the IF transformer should be replaced. If leakage is slightly higher than normal, changing resistor R-41 from 1 megohm to 220,000 ohms may correct the issue.
The 6BA6 tube may have grid emission even without RF circuit leakage into the A.V.C. system, particularly if manufactured before 1950. These tubes should be replaced with newer units.
Intermittent internal contact in 220 mmf mica condensers across the IF transformer windings can also cause sensitivity loss, though transformer leakage will not be apparent in this case.
An intermittent short at the tap on oscillator coil T-21 can cause issues on Bands 3 to 5. This can often be resolved by removing and resoldering the tap, then coating it with coil dope.