The Hallicrafters Super Skyrider manual provides detailed instructions for setting up, operating, and troubleshooting the 6-band, 13-tube superheterodyne receiver, including guidance on antenna connections, band selection, and control adjustments for optimal performance. It also covers specific procedures for receiving different types of signals, such as C.W. transmissions, and includes information on the tube lineup and the receiver's components to assist with alignment and servicing.
Manual Overview
The Hallicrafters Super Skyrider models S-17 and SX-17 are six-band, three-tube superheterodyne receivers designed for a wide range of frequencies, from 545 KC to 62.00 MC. Each band uses separate coils for optimal signal transfer, and the main dial is calibrated in kilocycles and megacycles. For troubleshooting, the manual emphasizes the importance of proper antenna setup, particularly for higher frequencies, and suggests experimenting with different antennae for maximum performance. Calibration involves adjusting the carrier level meter with the AVC switch on and the RF gain wide open, ensuring the meter reads zero with the antenna disconnected. The manual provides detailed guidance on the operation of the receiver, including the use of controls like RF gain, AF gain, and BFO injection for optimal reception of both voice and CW signals. The tube lineup includes stages for RF amplification, detection, and audio amplification, with specific components like the 6J5 signal frequency oscillator and 6V6 push-pull audio stage contributing to the receiver’s performance.
Quick Issues Covered
- Diagnose power-up failures with tube lineup checks.
- Calibrate main dial for accurate frequency tuning.
- Use schematics for circuit tracing and component verification.
Overview
The Super Skyrider models S-17 and SX-17 are 6-band, 13-tube superheterodyne receivers. They cover frequencies from 545 KC to 62.00 MC, using separate coils for each band to maximize signal energy transfer. The manual provides detailed operating instructions, including antenna setup, band selection, and controls for optimal reception of various signals. It also outlines the tube lineup and technical specifications, emphasizing the receiver’s design for superior performance and selectivity.
Specifications
- 6 band superheterodyne receiver
- 3 tube configuration
- Frequency coverage: 545 KC to 1,555 KC, 1,545 KC to 4,300 KC, 4.2 MC to 10.2 MC, 9.8 MC to 20.5 MC, 19.00 MC to 36.00 MC, 35.00 MC to 62.00 MC
- Separate coils for each band
- Inductive coupling to antenna
- Main dial calibrated in kilocycles and megacycles
- Tube line-up: 6K7, 6L7, 6J5, 6R7, 6V6, 6U7, 6H6, 5Z3
- Two stages of radio frequency amplification
- Iron-core transformers resonating at 465 KC
- Push-pull 6V6 stage delivering 13 watts of undistorted audio power
Operation
The operation of the Super Skyrider models S-I7 and SX-I7 involves several steps. Firstly, plug the receiver into a power socket, typically operating on 60 cycle 110 volt alternating current. Turn the “Tone” control to the right to power on the receiver. During warm-up, also turn the “RF Gain” and “AF Gain” knobs to the right. The receiver is initially set to the highest frequency range; adjust the “Bands” switch to select the desired band, as indicated by the pointer on the calibrated main dial. It is advised to start with Bands No. 1 and No. 2 before attempting higher frequencies.
For distant or weak signals, use the “BFO Injection” control by turning it to the right, but turn it off after locating the signals to avoid a continuous whistle. When listening to C.W. transmissions, keep the control on and adjust the “Pitch Control” knob for a pleasing beat note. The “AVC” switch should be off when the “BFO” control is on.
For phone reception, keep the “AVC” switch in the “On” position and turn the “RF Gain” control fully to the right until the snap switch is heard. If the set blocks on strong signals with the “AVC” switch off, manually adjust the “RF Gain” control to prevent overloading. Adjust both “RF Gain” and “AF Gain” controls for the best signal-to-noise ratio. The “Carrier Level” meter functions when the “AVC” switch is on and the “RF Gain” control is advanced to the right.
For C.W. signal reception, the “AVC” switch should be off and the “BFO Injection” control turned on. Adjust the control for minimum output to copy weak signals. Maximum beat oscillator output is achieved by turning the control fully to the right.