The manual provides detailed instructions for installing and calibrating the S-meter on the Hallicrafters Model CB-3A, including wiring connections and adjustments for accurate signal strength measurement. It also includes troubleshooting tips, such as checking soldered connections and periodically adjusting the potentiometer to ensure proper operation as the RF amplifier tube ages or is replaced.
Manual Overview
The Hallicrafters Model HA-9 manual provides detailed instructions for installing an S-meter on the Model CB-3A to measure relative signal strength and noise interference. The S-meter connects to the RF amplifier’s plate circuit and is calibrated in S units and decibels, with S9 set as the reference level. Installation involves mounting a 10K ohm potentiometer and connecting wires to the meter’s solder lugs. Specific wire lengths and connections are detailed, including the removal and reconnection of certain wires to the terminal strip and coil T2. The manual emphasizes careful inspection of soldered connections to prevent shorts and warns against touching meter terminals due to high voltage. Calibration involves adjusting the potentiometer for full-scale deflection with a non-magnetic screwdriver. Regular checks and adjustments may be necessary as the RF amplifier tube ages. The manual includes a parts list for reference.
Quick Issues Covered
- Diagnose S-meter calibration issues with potentiometer adjustment.
- Check solder connections for shorts causing power-up failures.
- Use schematic for circuit tracing in RF amplifier setup.
Overview
The S-meter is designed for use with the Hallicrafters Model CB-3A to indicate the relative signal strength of received signals. It also shows noise interference levels and indicates optimal transmission times. The meter is calibrated in S units and decibels over S9, with a reference level set at 50 microvolts. It is connected in the RF amplifier’s plate circuit and measures plate current. The manual provides detailed installation instructions, including wiring and mounting procedures.
Installation / Setup
The installation of the S-meter for the Model CB-3A involves several steps. First, mount the 10K ohm potentiometer in the specified location using the provided hardware. Prepare the meter by mounting the solder lugs and cover, and then connect a black wire to the negative terminal and a red wire to the positive terminal of the meter. Remove an orange wire from the existing setup and connect the new wires according to the instructions. After completing the wiring, inspect for any shorts. Once power is applied, adjust the potentiometer for full scale deflection on the S-meter. Periodic checks and adjustments may be necessary as the RF amplifier tube ages or is replaced.
Operation
The S-meter, when connected to the Hallicrafters Model CB-3A, provides an indication of the relative signal strength of received signals. In receive mode, it measures changes in the automatic volume control voltage, which affects the RF amplifier plate current, and this is indicated on the S-meter. The meter scale is calibrated in S units and decibels over S9. In transmit mode, the meter indicates the presence of carrier and modulation but does not read power output directly, so it cannot be used for transmitter tuneup or adjustment.
Safety & Warnings
DO NOT TOUCH THE METER TERMINALS AFTER POWER HAS BEEN APPLIED. HIGH VOLTAGE IS PRESENT ON THESE TERMINALS.