The manual for the Drake PS75 power supply covers the setup process, including line voltage programming and fuse installation, as well as the operation of the unit with solid state transceivers in CW or SSB modes. It also provides troubleshooting information, such as details on the connectors for VOX and ALC connections, and the specifications for AC input, DC output, and auxiliary connections.
Manual Overview
The Drake PS75 power supply manual provides detailed guidance on troubleshooting, error diagnostics, and maintenance for technicians. The PS75 delivers a nominal 13.6 VDC, supporting solid-state transceivers in CW or SSB modes. It operates from a switch-programmable primary voltage of 100, 120, 200, or 240 VAC, 50-60 Hz, providing 15 amperes continuously and up to 25 amperes peak. For troubleshooting, the manual emphasizes checking fuse integrity, with primary and high current outputs fused at the rear panel and regulated outputs protected on the internal printed circuit board. Calibration involves setting the voltage switch to the desired range and ensuring the correct fuse is installed for the operating voltage. Error diagnostics focus on verifying connections and fuse conditions. The manual also includes board-level guidance for fuse replacement and connector configurations, including VOX and ALC connections for linear amplifier use. The schematic diagram provides additional insights for technicians to address specific circuit issues.
Quick Issues Covered
- Diagnose power-up failures with fuse checks on rear panel.
- Error codes for voltage switch misconfiguration in line voltage programming.
- Use schematic for circuit tracing and correct fuse identification.
Overview
The PS75 is a high current, 13.6 VDC power supply designed for use with solid state transceivers in CW or SSB modes. It operates from a primary voltage of 100, 120, 200, or 240 VAC, 50-60 Hz, and provides 15 amperes continuous at an unregulated voltage of 13.6 VDC for solid state power amplifiers, along with a 3 ampere regulated output for the remainder of the transceiver. Additionally, it offers a regulated 13.6 VDC at 1 ampere for auxiliary equipment. The PS75 is primarily designed for SSB operation at current levels of 15 amperes average and 25 amperes peak, but it can also perform reliably on CW at current levels up to 25 amperes. The unit includes fuses for protection and connectors compatible with the Drake TR7 transceiver. The manual covers line voltage programming, linear amplifier connections, and provides specifications for AC input, DC output, connectors, dimensions, and weight.
Specifications
- AC Input: 100, 120, 200, or 240 VAC + 10% 50-60 Hz
- DC Output: 13.6 VDC (nominal) Unregulated @ 15 amps Continuous, 25 amps intermittent
- 13.6 VDC Regulated @ 3 amps
- DC Aux Volts: 13.6 VDC Regulated @ 1 amp
- Connectors: AUX DC — Phono Jack, ALC — Phono Jack, VOX — Phono Jack, Ground Connection
- Dimensions: Width = 9-5/8" (24.4 cm), Height = 5-1/6" (12.8 cm), Depth = 10-7/8” (27.6 cm)
- Weight: 20-1/2 Ibs. (9.3 kg)
Installation / Setup
The source does not provide specific information on installation or setup highlights such as wiring, clearances, or calibration for the PS75 power supply.
Operation
The PS75 power supply is used with solid state transceivers in CW or SSB modes. It operates from a primary voltage of 100, 120, 200, or 240 VAC, 50-60 Hz, and provides 15 amperes continuous at an unregulated voltage of 13.6 VDC for power amplifiers and a 3 ampere regulated output for the transceiver. It also offers a regulated 13.6 VDC at 1 ampere for auxiliary equipment. The supply is designed for SSB operation at 15 amperes average and 25 amperes peak, and can perform reliably on CW at up to 25 amperes. The primary and high current unregulated outputs are fused at the rear panel, while regulated outputs have a fuse on the circuit board. The PS75 is factory set for 120 VAC, and the input range can be changed by adjusting the voltage switch and installing the proper fuse. VOX and ALC connections for a linear amplifier are available on the rear panel.