The manual for the Drake FR-4tr Frequency Readout provides instructions for addressing readout stability issues on the 10 meter band, particularly when used with an RV-4 Remote VFO, by installing a 100 ohm resistor and an LC network. It also advises aligning the injection crystal oscillator according to the transceiver manual for optimal performance.
Manual Overview
The manual for the Drake FR-4tr Frequency Readout addresses troubleshooting for readout stability issues, particularly on the 10-meter band when used with an RV-4 Remote VFO. If stability problems occur, the manual suggests inserting a 100-ohm resistor in series with the counter cable connected to pin 7 of Vi in the transceiver. It provides detailed steps for disassembling the FR-4tr, including removing the top cover and circuit board screws. Technicians are instructed to unsolder the ungrounded conductor of the input cable and connect the long lead of the enclosed LC network coil to this point, while the short lead is soldered to the ground trace. The remaining capacitor lead is connected to the disconnected input lead. Ensuring secure connections and proper lead dressing is emphasized to prevent shorts. The manual also advises aligning the injection crystal oscillator per the transceiver manual, with specific sections referenced for TR-3 and TR-4 series owners.
Quick Issues Covered
- Diagnose readout stability issues on 10 meter band with RV-4 VFO.
- Calibrate injection crystal oscillator for TR-3 and TR-4 series.
- Trace circuit board connections for LC network installation.
Overview
The document is a letter addressing owners of the Model FR-4tr Frequency Readout, providing instructions to resolve stability issues on the 10 meter band when used with an RV-4 Remote VFO. It includes steps to install a 100-ohm resistor and an LC network to improve stability. The manual also advises aligning the injection crystal oscillator as per the transceiver manual for optimal performance.
Installation / Setup
The installation/setup highlights for the Model FR-4tr Frequency Readout include the following steps:
1. If experiencing stability problems, remove the counter cable from pin 7 of Vi in the transceiver and insert a 100 ohm resistor in series.
2. Remove the top cover of the FR-4tr by unscrewing the four sheet metal screws on the sides and the four machine screws fastening the circuit board.
3. Place the FR-4tr on its feet with the front panel facing you and locate the twisted cable from the left back connector to the circuit board.
4. Unsolder the ungrounded conductor of the input cable from the circuit board.
5. Solder the long lead of the coil portion of the enclosed filter to the point on the circuit board where the wire was removed, and solder the short coil lead to the ground trace.
6. Solder the unused end of the 33 pf capacitor to the disconnected input lead.
7. Ensure all connections are secure and leads are positioned to avoid shorting before reassembling the counter.
Additionally, it is recommended to align the injection crystal oscillator as indicated in the transceiver manual for optimal performance.