Drake 300VMF Instruction Manual (PDF)

The manual for the DRACOM 300VMF+ Commercial Video Modulator provides detailed instructions on the setup, operation, and troubleshooting of the device, including information on rear panel connections, installation, and frequency allocation. It also includes specifications for video and audio inputs, output levels, and safety precautions to ensure proper use and maintenance.

  • Brand: Drake
  • Model: 300VMF
  • Type: manual
  • File size: 168.8 KB

Manual Overview

The Drake MANUAL for the DRACOM 300VMF+ Commercial Video Modulator provides detailed instructions for troubleshooting, diagnostics, and calibration of the device. The manual emphasizes the importance of safety precautions, advising technicians to avoid exposing the unit to moisture and to refer servicing to qualified personnel to prevent electric shock. Troubleshooting involves checking connections and settings on the front panel, where all level controls are located for ease of access. The manual outlines error diagnostics through visual indicators and output test connectors, which provide a reduced level sample of the RF output signal for monitoring without affecting the signal quality. Calibration involves adjusting the A/V ratio and audio level using screwdriver adjustments on the front panel, ensuring the aural carrier is set approximately 15 dB below the visual carrier. For board-level guidance, the manual suggests consulting factory settings for custom channel configurations and maintaining frequency stability within specified tolerances. The manual also includes specifications for input and output levels, impedance, and frequency response to assist in precise adjustments and diagnostics.

Quick Issues Covered

  • Diagnose power-up failures with front panel power indicator.
  • Adjust audio/visual ratio using front panel A/V ratio control.
  • Use output test connector for RF signal monitoring.

Overview

The DRACOM 300VMF+ is a commercial video modulator designed for use in NTSC systems. It is a vestigial sideband heterodyne audio/video modulator that provides a modulated visual and aural RF carrier output on any single EIA standard channel from channel 2 through channel 78, plus channels 95 to 99, covering a frequency range of 54 through 552 MHz. The modulator is intended for use with equipment such as satellite receivers, TV cameras, video tape recorders, and TV demodulators. It features a heterodyne conversion system and a SAW filter for optimal vestigial selectivity in adjacent channel headends. The manual covers caution statements, important safety instructions, installation, frequency allocation charts, servicing information, and warranty details.

Specifications

  • Frequency Range: 54 – 552 MHz.
  • Channels Available: Factory ordered for a single channel: EIA CATV channels 2 to 78 and 95 to 99.
  • FCC Frequency Offsets: All aeronautical channels offset positive with a tolerance of +5 kHz.
  • Output Level: +55 dBmV, (typically adjustable from +43 to +55 dBmV).
  • Output Impedance: 75 OHMS, return loss of 14 dB, nominal.
  • Output Test: -30 dB, +3 dB (referenced to RF OUTPUT level).
  • A/V Ratio: Audio Carrier -20 to -12 dB referenced to video carrier, adjustable.
  • Frequency Stability, Visual: Within +10 kHz of assigned channel frequency; +5 kHz on FCC offset channels.
  • Aural Intercarrier Frequency: 4.5 MHz, +5 kHz.
  • Spurious Outputs: -60 dBc minimum, measured at -15 dB A/V ratio and with modulator output level of +55 dBmV.
  • In-Channel C/N: Better than 60 dB.
  • Broadband Noise: -95 dBc @ +30 MHz or greater spacings.
  • Modulator Power Requirement: 115 VAC +10%, 60Hz, 10 Watts.
  • Auxiliary AC Outlet: Nominal 120 VAC, 600 Watts, maximum.
  • Total AC Power Input: Nominal 120 VAC 60 Hz, 610 Watts, maximum.
  • Operating Temperature Range: 0° C to +50° C, ambient.
  • Size: 19" W x 1.75" H x 4.0" D.
  • Weight: 3.6 lbs.
  • Connectors: Video input, Audio input, RF output, and Monitor output are all type F.

Controls & Indicators

The front-panel controls and indicators for the DRACOM 300VMF+ Commercial Video Modulator include:

F1 – POWER Indicator: Lights when the unit is connected to a source of AC power.

F2 – OUTPUT TEST Connector: Provides a reduced level sample of the RF output signal, approximately 30 dB lower than the RF OUTPUT signal, for monitoring purposes.

F5 – A/V RATIO Control: A screwdriver adjustment that varies the level of the aural carrier from 12 to 20 dB below the visual carrier. Clockwise rotation increases the aural carrier level, decreasing the A/V ratio.

F6 – AUDIO LEVEL Control: A screwdriver adjustment that determines the peak aural carrier deviation.

Safety & Warnings

The manual contains several safety warnings and precautions:

1. There is a risk of electric shock due to non-insulated “dangerous voltage” within the product’s enclosure.
2. To reduce the risk of fire or electric shock, do not expose the appliance to rain or moisture.
3. Do not remove the cover or back of the appliance as there are no user-serviceable parts inside. Servicing should be referred to qualified personnel.
4. Do not attempt to service the product yourself as opening or removing covers may expose you to dangerous voltage or other hazards.
5. Do not use the apparatus near water and clean only with a dry cloth.
6. Do not block ventilation openings and install in accordance with the manufacturer’s instructions.
7. Do not install near heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.
8. Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
9. Only use attachments/accessories specified by the manufacturer.
10. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer. Use caution when moving the cart/apparatus combination to avoid injury from tip-over.
11. Unplug the apparatus during lightning storms or when unused for long periods of time.
12. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug damage, liquid spills, objects falling into the apparatus, exposure to rain or moisture, abnormal operation, or if it has been dropped.