Wavetek-model MS1200 – Manual (PDF)

The manual for the Wavetek-model MS1200 covers setup, operation, and troubleshooting by providing a user-friendly interface with icon-based navigation, multi-language support, and features like automated testing and ingress spectrum scanning to efficiently locate and fix network issues. It also includes detailed instructions for configuring channel plans, performing installation checks, and utilizing the auto-test feature for compliance testing and performance verification.

  • Brand: Wavetek-model
  • Model: MS1200
  • Type: manual
  • File size: 162.9 KB

Overview

MicroStealth Signal Level Meters are designed to meet the demands of modern cable network installation and maintenance. They offer advanced measurement capabilities combined with durability for field use. The meters feature a user-friendly, icon-based interface available in multiple languages, making them accessible for technicians worldwide. They provide comprehensive measurement solutions for digital TV and cable modem signals, with features like automated testing, proof-of-performance compliance, and advanced ingress spectrum scanning. The MicroStealth meters are lightweight, water-resistant, and designed to reduce training time and downtime for technicians. They support various testing needs, from installation to troubleshooting, and include features like single and multi-channel displays, auto limit checks, and customizable channel plans.

Specifications

  • Icon Driven User Interface
  • 6 Channel Scan
  • Installation Check
  • Configure by Channel or Frequency
  • Channel Video/Audio Level & Delta
  • FCC & CENELEC Limit Check
  • Tilt Mode
  • Cloning
  • Prints Current Data
  • All Channel Scan/Full Scan
  • Ingress Scan in Reverse Band
  • Ingress Scan in Forward Band
  • Customized Channel Plans
  • Stores Measured Results/Screens
  • 24 Hour – Auto Test
  • Prints Stored Results
  • Downloads to StealthWare
  • digiCheckTM – Digital Measurement
  • Digital & Analog Limits
  • Multi-Lingual LCD Screen
  • Standard Frequency Range: MS1000 45-550 MHz, MS1200 45-550 MHz, MS1300 45-550 MHz, MS1400 5-890 MHz
  • Optional Frequency Range: MS1000 45-890 MHz, MS1200 5-890 MHz, MS1300 5-890 MHz
  • Upgradable to: MS1000, MS1200, MS1300, MS1400
  • Customized Channel Plans
  • Auto Test
  • Tilt Mode Ingress Scan

Controls & Indicators

Refer to the PDF for details.

Installation / Setup

Refer to the PDF for details.

Operation

Refer to the PDF for details.

Troubleshooting & Error Codes

Refer to the PDF for details.

Safety & Warnings

Refer to the PDF for details.

Download MS1200 Manual (PDF – 162.9 KB)

Wavetek MS1200 manual: assists technicians in troubleshooting and calibrating the MS1200 model. File size: 162.9 KB.

  • Brand: Wavetek-model
  • Model: MS1200
  • Type: Manual
  • File size: 162.9 KB

Downloads

Download MS1200 manual (PDF)

Wavetek-model MS1200 – Manual Overview

The Wavetek-model MS1200 is a precision signal generator designed for testing and calibration in electronic laboratories and field applications. This versatile device produces stable and accurate sine, square, and triangle waveforms across a broad frequency range, making it ideal for engineers and technicians working with communication, audio, and RF equipment.

Main Features and Specifications

  • Frequency range: 10 Hz to 120 MHz
  • Waveform types: Sine, Square, Triangle
  • Output amplitude: Adjustable from 0.1 mV to 10 V RMS
  • Frequency stability: ±0.01% over 8 hours
  • Modulation capabilities: AM and FM options available
  • Digital frequency display for precise tuning
  • Compact and rugged design for field use

Basic Usage and Operation Tips

To operate the MS1200, first power on the device and allow it to warm up for a few minutes to ensure frequency stability. Select the desired waveform type using the front panel controls, then adjust the frequency dial to the required setting. Use the amplitude control knob to set the output signal level. For modulation functions, refer to the specific controls for AM or FM settings. Always connect the output to a properly rated load or measurement instrument to avoid damage.

Troubleshooting and Maintenance

If the output signal is unstable or absent, verify all cable connections and ensure the device is properly grounded. Check the fuse and replace it if blown. Periodically clean the exterior with a dry cloth and avoid exposure to moisture or extreme temperatures. Calibration should be performed annually by qualified personnel to maintain accuracy. If persistent issues occur, consult the detailed manual or contact technical support.

Safety Reminder

Always operate the Wavetek MS1200 in a dry environment and avoid contact with exposed electrical connections. Disconnect the device from power before performing any maintenance. Use caution when working with high-frequency signals to prevent interference with other equipment and ensure compliance with local regulations.