BK Precision AV-1A Instruction Service Manual (PDF)

The service manual for the Dynascan Model AV-1A R.F. Probe provides instructions for setup and operation with various vacuum tube voltmeters, detailing how to connect the probe and interpret DC readings as RMS values of sine wave voltages. It also includes troubleshooting tips, such as ensuring the use of the correct ground lead to avoid inaccurate readings, and specifies the voltage limits for safe operation.

  • Brand: BK Precision
  • Model: AV-1A
  • Type: service manual
  • File size: 166.2 KB

Manual Overview

The service manual for the Dynascan Model AV-1A R.F. Probe provides detailed instructions for its use with various vacuum tube voltmeters, including B & K Models 175, 177, and 375, as well as Precision Apparatus Models V-75, V-95, and 48. The probe is designed to measure sine wave voltages at frequencies up to 250 MHz using a crystal diode as a half-wave rectifier. This rectifier generates a DC voltage proportional to the peak value of the sine wave input signal, which is then converted to an RMS reading using a calibrating resistor. For accurate measurements, the probe must be connected to the VTVM with the Selector Switch set to the +DC position and the DC ranges used on the Range Switch. It is crucial to use the probe’s ground lead for the circuit under test to avoid inaccurate readings. The probe is suitable for circuits with DC voltages up to 400V and AC voltages up to 25V RMS. The manual also includes a replacement parts list for maintenance and repair.

Quick Issues Covered

  • Diagnose inaccurate readings due to improper grounding techniques.
  • Calibrate using R-1 resistor for accurate RMS voltage measurements.
  • Refer to schematic for circuit tracing and component replacement.

Overview

The Dynascan Model AV-1A R.F. Probe is designed for use with various vacuum tube voltmeters, including specific models from B & K and Precision Apparatus, as well as most VIVMs with 11 megohm input resistance. It allows for the measurement of sine wave voltages at frequencies up to 250 MHz using a crystal diode as a half wave rectifier. The probe is suitable for circuits where the DC voltage does not exceed 400V and the AC voltage does not exceed 25V RMS. The manual provides instructions on connecting the probe and obtaining accurate RMS readings, as well as a replacement parts list.

Specifications

  • Sine wave voltage measurement up to 250 MHz
  • Crystal diode half wave rectifier
  • DC voltage limit: 400V
  • AC voltage limit: 25V RMS

Operation

The Dynascan Model AV-1A R.F. Probe is used with various vacuum tube voltmeters to measure sine wave voltages at frequencies up to 250 MHz. It employs a crystal diode as a half-wave rectifier to develop a DC voltage proportional to the peak value of the sine wave input signal. To use the probe, connect it to the VTVM, set the Selector Switch to the +DC position, and use the DC ranges on the Range Switch. The DC readings obtained will be the RMS readings of the sine wave being measured. The probe should be grounded using its own ground lead, not the long separate ground lead from the VTVM front panel, to ensure accurate readings. It can be used in circuits where the DC voltage does not exceed 400V and the AC voltage does not exceed 25V RMS.

Download PDF (166.2 KB)

Leave a Comment