The B+K Precision Model 4011A Function Generator manual covers setup and operation instructions, including frequency and waveform selection, as well as controls for duty cycle, DC offset, and output level. It also provides troubleshooting guidance, such as fuse replacement and line voltage selection, to ensure the proper functioning of the device.
Manual Overview
The B+K Precision Model 4011A Function Generator manual provides detailed instructions for troubleshooting, error diagnostics, calibration, and adjustments. The function generator is capable of producing sine, square, and triangle waveforms across a frequency range of 0.5 Hz to 5 MHz, with a built-in frequency counter for precise output frequency determination. Troubleshooting involves checking the power and range switches, ensuring proper waveform selection, and verifying the settings of the duty cycle, CMOS level, and DC offset controls. Error diagnostics are facilitated by the frequency counter display, which updates based on the selected frequency range, indicated by the GATE LED. Calibration and adjustments can be made using the coarse and fine frequency controls, as well as the output level and DC offset controls. Board-level guidance includes replacing fuses and selecting line voltage. The manual emphasizes the importance of connecting the unit to an oscilloscope for observing waveform effects and adjusting settings accordingly.
Quick Issues Covered
- Diagnose power-up failures with front panel controls and indicators.
- Use error codes for frequency counter accuracy troubleshooting.
- Schematics aid in circuit tracing for output waveform issues.
Overview
The B+K Precision Model 4011A Function Generator is a versatile signal source that combines multiple functions into one unit. It features a voltage-controlled generator (VCG) capable of producing precision sine, square, or triangle waves over a frequency range of 0.5 Hz to 5 MHz. This range supports subaudible, audio, ultrasonic, and RF applications. The function generator includes a built-in frequency counter for accurate output frequency determination, coarse and fine tuning controls for precision frequency setting, and high stability to prevent frequency drift. It offers variable waveform symmetry for generating rectangular waves, pulses, ramp or sawtooth waves, and slewed sine waves. The unit can also accept an external signal to sweep or control the operating frequency, making it suitable for various applications in analog and digital electronics across engineering, manufacturing, servicing, educational, and hobbyist fields.
Specifications
- FREQUENCY CHARACTERISTICS
- Waveforms: Sine, Square, Triangle, Pulse, Ramp
- Range: 0.5 Hz to 5 MHz in 7 ranges
- Resolution: 4 digit
- Tuning Range: Coarse: 10:1, Fine: ±5% of Coarse Setting
- Frequency Stability: Output frequency will not change more than 0.09% in 15 minutes after 1 hour warmup
- OUTPUT CHARACTERISTICS
- Impedance: 50Ω ±10%
- Level: 20 V p-p Open-circuit, 10V p-p into 50Ω
- TTL OUTPUT
- Level: 0.8V to 2.4V
- Rise Time: ≤20 nS
- Duty Cycle: 50% typical
- CMOS OUTPUT
- Max Frequency: 2 MHz
- Level: 4V to 14V, 0.45V p-p
- Rise Time: ≤120 nS
- VCG (Voltage Controlled Generator) INPUT
- Input Voltage: 0-10V ±1V causes a 100:1 frequency change
- Impedance: 10kΩ ±5%
- FREQUENCY COUNTER
- Time Base Accuracy: ±10 PPM (23°C ±5°C)
- POWER SOURCE
- 120/230 VAC ±10%, 50/60 Hz, internal jumper selectable
- DIMENSIONS (H x W x D)
- 10-3/8" x 3-3/8" x 11-7/16" (26.4cm x 8.6cm x 29.1cm)
- WEIGHT
- 4 lb. (1.8 kg.)
- ACCESSORIES
- Instruction Manual
- Output Cable, BNC to Alligator Clips
Controls & Indicators
The front-panel controls and indicators for the MODEL 4011A Function Generator are as follows:
1. POWER Switch: Turns the power on and off.
2. RANGE Switch: Selects output frequency range from 5 Hz to 5 MHz, adjustable with the COARSE FREQUENCY control.
3. FUNCTION Switch: Selects sine, square, or triangle waveform at the OUTPUT jack.
4. OUTPUT LEVEL Control: Controls the amplitude of the signal at the OUTPUT jack.
5. DC OFFSET Control: Adjusts the DC offset in a positive or negative direction when enabled.
6. OUTPUT Jack: Provides the waveform selected by the FUNCTION switch and DC OFFSET voltage.
7. TTL/CMOS Jack: Outputs TTL or CMOS square wave, depending on the CMOS LEVEL switch position.
8. CMOS LEVEL Control: Increases the amplitude of the CMOS square wave at the TTL/CMOS jack.
9. VCG Jack: Allows external control of generator output frequency by a DC voltage input.
10. DUTY CYCLE Control: Adjusts the duty cycle of the main OUTPUT signal when enabled.
11. -20DB Switch: Attenuates the signal at the OUTPUT jack by 20db when engaged.
12. DC OFFSET Switch: Enables operation of the DC OFFSET control.
13. CMOS LEVEL Switch: Changes the TTL signal to CMOS signal at the TTL/CMOS jack when engaged.
14. DUTY CYCLE Switch: Enables operation of the DUTY CYCLE control.
15. FINE FREQUENCY Control: Provides vernier adjustment of the output frequency.
16. COARSE FREQUENCY Control: Provides coarse adjustment of the output frequency.
17. COUNTER DISPLAY: Displays frequency of internally generated waveform.
18. GATE LED: Indicates when the frequency counter display is updated.
19. Hz and KHz LED: Indicates whether the counter is reading in Hz or KHz.
Operation
The B+K Precision Model 4011A Function Generator is a versatile instrument capable of producing various output waveforms over a broad range of frequencies. To gain familiarity with the unit, it is recommended to connect it initially to an oscilloscope to observe the effects of the various controls on the output waveforms. The manual should be used as a reference until the user becomes accustomed to the operating procedures.
For frequency and waveform selection, initially verify that the DUTY CYCLE, CMOS LEVEL, DC OFFSET, and -20dB switches are in the OUT position to produce a symmetrical waveform unaffected by other controls. Plug the unit into an appropriate power source and turn it on using the POWER switch. Select the desired waveform (SINE, SQUARE, or TRIANGLE) by engaging one of the function switches.
Safety & Warnings
The source document does not contain any specific safety warnings or precautions.
Download MANUAL Manual (PDF – 452.5 KB)