BK Precision 2880B Instruction Manual (PDF)

The BK Precision Instruction Manual for models 2880B and 2890A covers setup, operation, and troubleshooting of the dual display True-RMS digital multimeter, including instructions on entering setup mode, operating the device for various measurements such as AC/DC voltage, current, resistance, and temperature, and utilizing features like data hold and dynamic recording. It also provides safety guidelines, maintenance tips, and information on the multimeter's capabilities, such as frequency counter, capacitance measurement, and remote communication.

  • Brand: BK Precision
  • Model: 2880B
  • Type: manual
  • File size: 2.8 MB

Manual Overview

The BK Precision 2880B and 2890A True-RMS Digital Multimeters are designed for industrial and laboratory use, offering a range of measurement capabilities including DCV, ACV, DCA, ACA, resistance, capacitance, frequency, and temperature. The manual provides detailed troubleshooting guidance, emphasizing the importance of understanding error codes and diagnostics for effective problem resolution. Calibration and adjustment procedures are outlined to ensure accurate measurements, with specific instructions for board-level adjustments. The multimeters feature a dual display for simultaneous measurement readings, and the 2890A model includes advanced functions like AC+DC true RMS measurement and square wave output. Error codes are crucial for diagnosing issues, and the manual advises on interpreting these codes to identify faults. Calibration involves using the built-in precision features to maintain measurement accuracy. The manual also covers remote communication setup, enabling data transfer and control via computer interface. Maintenance sections include battery and fuse replacement, ensuring the device remains operational and safe for use.

Quick Issues Covered

  • Diagnose power-up failures with factory reset instructions.
  • Error codes for overload and input warnings.
  • Calibration adjustments for accurate frequency and temperature readings.

Overview

BK Precision’s Model 2880B and 2890A are dual display, 51,000 count True-RMS digital multimeters designed for testing and troubleshooting power electronic systems. These handheld, battery-operated instruments are suitable for industrial fields and laboratories. They offer a range of features including DCV, ACV, DCA, ACA, OHM, diode check, audible continuity, temperature, frequency, duty cycle, and pulse width tests. The 2890A model provides AC+DC true RMS measurement for both voltage and current, while both models offer ambient temperature display, battery capacity indication, and a brightness LED backlight. The multimeters are designed to meet IEC-1010 CAT. III 1000V and CAT. IV 600V standards, ensuring safety and precision.

Specifications

  • DCV, ACV, DCA, ACA, OHM, Diode check, Audible continuity, Temperature, Frequency, Duty cycle and Pulse Width tests
  • AC+DC true RMS measurement for both voltage and current (model 2890A only)
  • AC true RMS measurement for both voltage and current
  • Ambient temperature display with main measurement
  • Battery capacity indication
  • Brightness LED backlight
  • Resistance measurement up to 50MΩ
  • Conductance measurement from 0.01nS (100GΩ) ~ 50nS
  • Capacitance measurement up to 100mF
  • Frequency counter up to 20MHz
  • The % scale readout for 4-20mA or 0-20mA measurement
  • dBm with selectable reference impedance
  • 1ms Peak hold to catch inrush voltage and current easily
  • Temperature test with the selectable 0°C compensation (optional Temp adapter required)
  • K type temperature with environment compensation selection (optional Temp adapter required)
  • Frequency, Duty cycle and Pulse width measurements
  • Dynamic Recording for Min/Max/Average
  • Data Hold with Manual or Auto Trigger and Relative modes
  • Diode and Audible Continuity Test
  • Bi-directional optic computer interface with SCPI commands
  • Safe, precision and speed closed case calibration
  • 50,000 count precision True-RMS digital multi-meter and designed to meet IEC-1010 CAT. III 1000V and CAT. IV 600V standards
  • Built-in rechargeable battery
  • Smart Charger design without battery removal (optional accessory)

Safety & Warnings

The safety warnings and precautions explicitly present in the manual include:

– Read the operation manual completely before using the device and follow all safety instructions.
– The device is for indoor use, at altitudes up to 2,000 meters.
– Avoid working alone.
– Use the device only as specified in the manual; otherwise, the protection provided by the meter may be impaired.
– Never measure voltage when the current measurement is selected.
– Do not use the device if it looks damaged.
– Inspect the leads for damaged insulation or exposed metal and replace damaged leads.
– Disconnect the power and discharge all high-voltage capacitors before testing in the resistance, continuity, and diode function.
– Be cautious when working above 70VDC or 33VRMS and 46.7V peak, as such voltages may cause a shock hazard.
– Always keep hands behind the protective guard of the probe while measuring.
– Select the proper function and disconnect the test leads from test points before changing functions.
– Always use the specified battery.
– The meter is safety-certified in compliance with EN61010 (IEC 1010-1, IEC 1010-2-031) installation Category IV 600V/ III 1000V Pollution Degree 2. To maintain its insulation properties, use standard or compatible test probes.
– Under the influence of an RF field according to the standard, the supplied test leads will pick up induced noise. For better shielding, a short-twisted lead should be used.

Download PDF (2.8 MB)