BK Precision 1746 Instruction Manual (PDF)

The B+K Precision Model 1746 DC Power Supply manual provides detailed instructions for setting up and operating the power supply, including safety precautions, operating instructions, and specifications for voltage and current output. It also includes troubleshooting tips, such as handling high voltage hazards and ensuring proper connections to prevent electrical shock and equipment damage.

  • Brand: BK Precision
  • Model: 1746
  • Type: manual
  • File size: 1000.8 KB

Manual Overview

The B+K Precision Model 1746 DC Power Supply manual provides detailed guidance on troubleshooting, diagnostics, and calibration for technicians. The power supply offers a 0-16V output with a current range of 0-10A, featuring both coarse and fine adjustments for precision. It includes two current ranges, High and Low, to enhance current settability and meter resolution. The manual emphasizes the importance of safety, particularly when dealing with high voltage, and advises using a polarized 3-wire AC outlet to minimize shock hazards. For troubleshooting, the manual highlights the automatic crossover between constant voltage and constant current modes, indicated by LEDs. Error diagnostics are facilitated by built-in metering that continuously monitors output voltage and current. Calibration involves setting current limits from 5% to 100% of maximum output, ensuring protection against overloads and reverse polarity. The manual also provides board-level guidance for connecting two power supplies in series or parallel to extend voltage or current capabilities.

Quick Issues Covered

  • Diagnose power-up failures with voltage and current output checks.
  • Error codes for overload and reverse polarity protection issues.
  • Calibration adjustments for precise voltage and current settings.

Overview

The B+K Precision Model 1746 is a DC power supply designed for general-purpose use, providing an output of 0-16 volts and 0-10 amps. It features both constant voltage and constant current modes, with smooth automatic crossover between the two. The power supply includes coarse and fine controls for precise voltage adjustment and two current ranges for enhanced settability and meter resolution. It is equipped with reverse polarity protection and adjustable current limiting to protect both the power supply and the equipment under test. The output is isolated from chassis and earth ground, allowing flexible connections. The Model 1746 is suitable for various applications, including electronics servicing, manufacturing, design labs, education, battery charging, and more.

Specifications

  • OUTPUT VOLTAGE
  • 0 to 16 VDC, coarse and fine adjustment
  • OUTPUT CURRENT
  • High Range — 0 to 10A
  • Low Range — 0 to 2A
  • CONSTANT VOLTAGE OPERATION
  • Voltage Regulation
  • Accuracy +2.5%
  • Line (108-132) <(0.2% +2 mV)
  • Load (no load to full load) <(0.04% +2 mV)
  • Recovery Time <100us typical
  • Ripple Voltage
  • RMS <1mV
  • Temperature Coefficient
  • 0° to +40° C $300 PPM/° C
  • CONSTANT CURRENT OPERATION
  • Adjustable Current Limits
  • METERING
  • Voltmeter
  • Ammeter
  • POWER REQUIREMENTS
  • Domestic: 120 VAC 10%, 60 Hz
  • International: 120, 220, 230, 240 VAC +10%, 50/60 Hz
  • POWER CONSUMPTION
  • Approximately 380 Watts or less at full load

Operation

The B+K Precision Model 1746 DC Power Supply operates in two main modes: constant voltage and constant current. The crossover between these modes is smooth and automatic, with LED indicators showing the current mode. In constant voltage mode, users can preset a current limit, and if load variations cause the current to reach this limit, the unit will regulate the output current instead of the voltage. Current limits are adjustable from 5% to 100% of the maximum output. For constant current applications, the maximum voltage can be preset, and if load variations cause the current to drop below the regulated value, the unit will revert to regulated voltage operation. The power supply features coarse and fine controls for precise voltage adjustment and provides an output of 0-16 volts and 0-10 amps. It includes safety features like reverse polarity protection and overload protection. The output is isolated from the chassis and earth ground, allowing for flexible connections. Two supplies can be connected in series or parallel for increased voltage or current output.

Safety & Warnings

Normal use of test equipment can expose users to electrical shock, especially when testing in areas with exposed high voltage. Electrical shock causing 10 milliamps of current through the heart can stop most human heartbeats. Voltage as low as 35 volts dc or ac rms is considered dangerous and hazardous as it can produce a lethal current under certain conditions. Higher voltages are even more dangerous. Users should adopt practices to prevent contact with exposed high voltage and steer current away from the heart in case of accidental contact. Specific precautions include:

1. There is little danger of electrical shock from the dc output of the power supply, but certain test conditions can create a high voltage shock hazard:
a. A serious shock hazard exists with “hot chassis” type equipment unless unplugged or an isolation transformer is used.
b. If equipment under test is “powered up” and uses high voltage, power supply outputs may float to the potential at the connection point. High voltage may appear unexpectedly in defective equipment. Do not float the power supply output to more than 100 volts peak with respect to chassis or earth ground.
c. If equipment is “off” but uses high voltage, discharge high-voltage capacitors before making connections or tests. Some circuits retain high voltage long after being turned off.

2. Use only a polarized 3-wire ac outlet to ensure the power supply chassis, case, and ground terminal are connected to a good earth ground, reducing electrical shock danger.

3. Avoid exposing high voltage unnecessarily. Remove housings and covers only when necessary. Turn off equipment while making test connections in high-voltage circuits. Discharge high-voltage capacitors after removing power.

Download PDF (1000.8 KB)