BK Precision 1403A Instruction Maintenance Manual (PDF)

The B&K Model 1403A Oscilloscope manual provides detailed instructions for setting up, operating, and troubleshooting the oscilloscope, including descriptions of its features, specifications, and circuit design. It also includes guidance on handling, adjustments, and maintenance to ensure optimal performance and longevity of the device.

  • Brand: BK Precision
  • Model: 1403A
  • Type: manual
  • File size: 1.4 MB

Manual Overview

The B&K Model 1403A Oscilloscope manual provides comprehensive guidance for technicians on troubleshooting, error diagnostics, calibration, and board-level adjustments. The oscilloscope features a vertical-axis sensitivity of better than 10 mV/DIV and a frequency response from DC to 5 MHz, utilizing DC amplifiers for both axes. For troubleshooting, the manual emphasizes the importance of checking the vertical and horizontal circuits, which employ FET and silicon transistors for stability and gain control. Error diagnostics involve monitoring the sweep frequency and ensuring synchronization, with internal and external sync options available. Calibration and adjustments are facilitated through the vertical attenuator and EXT GAIN control, allowing for precise signal measurement and amplification. The power supply circuit provides stabilized voltages necessary for the oscilloscope’s operation. Technicians are advised to refer to the block diagram for detailed circuit descriptions and to follow the operating instructions for proper use and maintenance of the oscilloscope.

Quick Issues Covered

  • Diagnose vertical amplifier issues with deflection sensitivity below 10 mV/DIV.
  • Identify power-up failures with power supply circuit providing incorrect voltages.
  • Use schematics for circuit tracing and troubleshooting horizontal amplifier faults.

Overview

The B & K Model 1403A Oscilloscope is a highly sensitive and stable oscilloscope featuring a 3-inch cathode ray tube. It is designed for easy operation and includes features such as vertical-axis sensitivity better than 10 mV/DIV, a frequency response from DC to 5 MHz, and all transistorized circuitry for low power consumption. The manual covers features, specifications, circuit description, operating instructions, applications, handling cautions, adjustments, and maintenance.

Specifications

  • CATHODE RAY TUBE: C3 12 P31B or 75AV31
  • VERTICAL AMPLIFIER:
  • Deflection sensitivity: 10 mV/DIV or better
  • Frequency response: DC to 5 MHz (-3 dB), AC 2Hz to 5MHz (-3dB)
  • Input impedance: 1 MΩ shunted by 35 pF max
  • Overshoot: 5% or less
  • Attenuator: Multiplier within 5%
  • Gain control range: Continuously variable range greater than 22 dB
  • Rated maximum input voltage: 300 VDC + AC peak or 600 Vp-p
  • HORIZONTAL AMPLIFIER:
  • Deflection sensitivity: 300 mV/DIV or better
  • Frequency response: DC to 250 kHz with EXT.GAIN Control set at maximum, DC to approx. 40 kHz with EXT.GAIN Control set at mid-range
  • Input impedance: Shunted by 30 pF max. (SYNC-*INT), 1 MΩ
  • Attenuator (EXT. GAIN): Variable, continuously to zero
  • Rated maximum input voltage: 100 Vp-p
  • SWEEP CHARACTERISTICS:
  • Sweep frequency: 10 Hz to 100 kHz continuously variable in 4 ranges
  • Sweep linearity: Within 5%
  • Synchronizing: Internal or external negative
  • Signal amplitude requirement: Internal: more than 1 DIV deflection on cathode ray tube screen, External: more than 2 Vp-p
  • INTENSITY MODULATION:
  • Required signal: 25 Vp-p
  • DIRECT DEFLECTION TERMINALS:
  • Deflection sensitivity: 10 V/DIV or better
  • Input impedance: 2.2 MΩ shunted by 25 pF or less
  • POWER REQUIREMENTS: 117/230 VAC, 50/60 Hz, 16 watts (Unit delivered for use on 117 VAC, 50/60 Hz)
  • DIMENSIONS, OVERALL: Width: 7-1/2" (190 mm), Height: 6" (154 mm), Depth: 11-27/32" (300 mm)
  • WEIGHT: 8.36 lbs. (3.8 kg)

Controls & Indicators

The front-panel controls and indicators include:

1. Neon Pilot: Illuminates when the oscilloscope is operating.
2. Power: ON-OFF switch to bring the oscilloscope to operating condition.
3. EXT.SYNC/ HOR INPUT: Input terminal for external sync or horizontal signal, with a grounding terminal for common grounding.
4. Grounding terminal.
5. VERT INPUT: Input terminal for the vertical signal, spaced for dual banana plug insertion.
6. AC-DC Selector: Switch for vertical input coupling capacitor, allowing DC or AC coupling.
7. V. ATT: Vertical attenuator to adjust the signal voltage connected to the VERT INPUT before amplification, with positions for direct coupling, attenuation, and grounding for DC BAL adjustments.

Operation

The source provides detailed operating instructions for the B & K Model 1403A Oscilloscope. The front panel controls and terminals are marked and described as follows:

1. Neon Pilot: Illuminates when the oscilloscope is operating.
2. Power: ON-OFF switch to bring the oscilloscope to operating condition.
3. EXT.SYNC/ HORIZ INPUT: Input terminal for external sync or horizontal signal, using the grounding terminal as common ground.
4. Grounding Terminal: Common grounding terminal.
5. VERT INPUT: Input terminal for the vertical signal, spaced for dual banana plug insertion.
6. AC-DC Switch: Selector switch for vertical input coupling capacitor. In DC position, directly couples the VERT INPUT terminal and V. ATT, allowing the vertical amplifier to amplify input signals from DC. In AC position, a capacitor blocks the DC component, allowing observation of the AC component only.
7. V. ATT: Vertical attenuator to adjust the signal voltage connected to the VERT INPUT terminal to a suitable level before application to the vertical amplifier. It has positions for direct coupling, attenuation to 1/10 and 1/100 of normal value, and a GND position for grounding the input of the vertical amplifier and opening the VERT INPUT terminal for DC BAL adjustments.

The manual suggests using the GND position of the attenuator for making DC BAL adjustments. Signal voltage measurement guidelines are also provided for different attenuator settings.

Download PDF (1.4 MB)

Leave a Comment