Rohde & Schwarz NV14T Multi Coupler Operation Service Manual (PDF)

The service manual for the Rohde & Schwarz Type NV14T Multi-Coupler covers the setup and operation of the device, including connection to power supply and RF cables, and states that the unit is ready for operation after switching on the operating voltage without requiring any trimming or checks. It also provides detailed troubleshooting instructions, including maintenance and repair procedures, necessary measuring instruments, and recalibration guidelines to ensure optimal performance.

  • Brand: Rohde & Schwarz
  • Model: NV14T
  • Type: service manual
  • File size: 2.3 MB

Manual Overview

The service manual for the Rohde & Schwarz NV14T Multi-Coupler provides detailed instructions for troubleshooting, diagnostics, calibration, and repair. The manual emphasizes the importance of using appropriate measuring instruments, such as digital multimeters and millivoltmeters, for accurate diagnostics. Troubleshooting involves checking electrical characteristics like frequency response, input impedance, and isolation between outputs. Error codes are not explicitly mentioned, but diagnostics focus on measuring parameters like noise figure and gain. Calibration and adjustments are necessary for maintaining optimal performance, with recalibration procedures outlined for frequency response and impedance checks. Board-level guidance includes descriptions of circuit components such as the amplifier section, output coupling network, and feedback mechanisms. The manual also provides repair instructions, detailing the roles of overvoltage protection, current and voltage regulators, and mechanical construction. Proper connection to power supply and RF cables is crucial for operation, and no additional trimming is required once the unit is powered. The manual ensures technicians can effectively maintain and repair the NV14T to support its use in both small and large receiver systems.

Quick Issues Covered

  • Diagnose power-up failures with 24V power supply connection issues.
  • Recalibrate frequency response and input impedance with Polyskop SWOB.
  • Use schematics for circuit tracing in amplifier and isolation network.

Overview

The NV14T Multi-Coupler by Rohde & Schwarz is a wideband amplifier designed for low noise and distortion, operating within the shortwave range of 1.6 to 30 MHz or 1.0 to 30 MHz, depending on the model. It allows up to 10 receivers to be connected to a single antenna without signal loss. The device can be used as a standalone unit with the NV 142 N power supply or integrated into larger systems using the NV 142 EB rack adapter. The multi-coupler features silicon transistors, a common-base circuit, and a two-stage emitter follower with large negative feedback to minimize distortion. It is split into an amplifier and a passive isolation network to ensure signal integrity across outputs. The NV14T is suitable for both small and large receiving stations, supporting up to 1000 receivers through cascading.

Specifications

  • Frequency range: 1.6 to 30 MHz or 1.0 to 30 MHz
  • Input impedance: 50 Ω, VSWR <2
  • Output impedance: 50 Ω, VSWR 1.1
  • Number of outputs: 10
  • Isolation between outputs: > 40 dB
  • Input and output connections: BNC sockets
  • Voltage gain: 48 ±0.5 dB
  • Noise figure: see tolerance diagram section 3.2.2.3
  • Mixture-product suppression for a wanted transmitter EMF of 2 x 300 mV: 70 dB for all measured values, 75 dB for more than 90% of all measured values
  • Mixture-product suppression for 3rd order mixture product: 80 dB for all measured values, 85 dB for more than 90% of all measured values
  • Cross modulation: with interfering transmitter modulated 30%, cross modulation of 10% occurs
  • Frequency of interfering transmitter: 1 to 10 MHz, 10 to 20 MHz, 20 to 30 MHz
  • EMF of interfering transmitter: 4 V, 3.4 V, 2.6 V
  • Power supply: 24 V ±0.5 V
  • Current drain: 500 mA max.
  • Permissible ambient temperature: -40°C to 45°C
  • Dimensions (HxWxD): 132.5 x 52.6 x 175 mm
  • Weight: 1.3 kg

Installation / Setup

The installation/setup highlights for the ROHDE & SCHWARZ TYPE NV14T MULTI-COUPLER include the following:

1. Power Supply Connection: Connect a power supply of 24 V +0.5 V (0.6 A, max.) using a cable with the connector FO 063.7983.

2. RF Cable Connection: The input and outputs are equipped with BNC sockets with an impedance of 50 ohms. If all outputs are used, BNC connectors FHM 10012/50 (without compression nut) should be used.

3. Operating Instructions: The unit is ready for operation after switching on the operating voltage. No trimming or checks are required.

Download PDF (2.3 MB)