The manual for the R&S FSH-K1 covers the setup of remote control options, including enabling the feature with a key code and connecting the device to a PC using USB or RS232 interfaces. It also provides detailed instructions for installing necessary drivers, configuring serial ports, and troubleshooting common issues such as incorrect key code entries.
Manual Overview
The operation manual for the R&S FSH-K1 Remote Control Option provides detailed instructions for enabling remote control, troubleshooting, and configuring connections. To enable the remote control feature, users must enter a key code specific to the instrument’s serial number. If an incorrect code is entered, an “Option key error” message will appear, allowing users to retry. For troubleshooting, the manual outlines error messages and their corresponding responses. The device can be connected to a PC via USB or RS232 interfaces, with specific cables provided to prevent interference. The USB optical cable requires driver installation from the R&S FSH CD-ROM, which emulates a serial COM port on the PC. Serial port configuration should be set to 8 data bits, 1 stop bit, no parity, with baud rates adjustable through the device’s setup menu. The manual also includes guidance on command functions, parameter settings, and board-level adjustments for optimal operation.
Quick Issues Covered
- Diagnose 'Option key error' during remote control setup.
- Install USB driver for R&S FSH-Z37 cable.
- Configure serial port: 8 data bits, 1 stop bit, no parity.
Overview
The R&S FSH spectrum analyzer can be equipped with the Remote Control Option R&S FSH-K1, which is activated by entering a key code based on the instrument’s unique serial number. This option allows the device to be controlled remotely via a PC or laptop using a USB or RS232 interface. The manual covers the installation of necessary drivers, configuration of serial ports, and provides instructions for enabling the remote control feature.
Installation / Setup
The setup for the R&S FSH-K1 involves connecting the spectrum analyzer to a PC or laptop using either a USB or RS232 interface. The RS232 optical interface is located on the right-hand side of the R&S FSH and can be accessed by folding out the support. The USB Optical Interface Cable (R&S FSH-Z37) or the RS232 Optical Interface Cable (R&S FSH-Z34) is used for the connection. The USB cable requires installation of a driver from the R&S FSH CD-ROM, which emulates a serial COM port on the PC. The installation process involves connecting the cable, inserting the CD-ROM, and following the hardware installation wizard. The serial port configuration on the PC should be set to 8 data bits, 1 stop bit, no parity, with configurable baud rates of 9,600 to 115,200 Baud, defaulting to 19,200 Baud.
Operation
The manual provides steps for enabling the Remote Control Option R&S FSH-K1 on the R&S FSH spectrum analyzer. To enable this option, press the GENERAL key, select the OPTIONS menu using the Rotary knob or Cursor keys, and confirm with the ENTER key. Enter the ten-digit key code for the option using the decimal keys and confirm with ENTER. If the correct key code is entered, “Remote Control enabled” is displayed; otherwise, “Option key error” is shown, allowing for re-entry of the correct code.
For connecting PCs, the R&S FSH can be remote controlled via a USB or RS232 interface. The RS232 optical interface is located on the right-hand side of the R&S FSH, accessible by folding out the support. Use the USB Optical Interface Cable R&S FSH-Z37 or the RS232 Optical Interface Cable R&S FSH-Z34 for connection. The USB cable requires driver installation from the R&S FSH CD-ROM, which emulates a serial COM port on the PC. The installation involves connecting the cable, using the hardware installation wizard, and finalizing the setup.
The serial port configuration on the PC should be set to 8 data bits, 1 stop bit, no parity, with configurable baud rates of 9.600, 19.200, 38.400, 57.600, or 115.200 Baud. The default baud rate is 19.200 Baud.