The Kenwood TR-2600A instruction manual provides detailed guidance on setting up the transceiver, including battery charging and installation, as well as operating instructions for using the controls and terminals. It also offers troubleshooting tips, such as resetting the microprocessor and ensuring proper battery maintenance to prevent memory loss and ensure optimal performance.
Manual Overview
The Kenwood TR-2600A instruction manual provides detailed guidance for the operation, troubleshooting, and maintenance of the transceiver. For troubleshooting, the manual emphasizes the importance of using the supplied charger and cautions against connecting an external DC supply directly to the charge terminal to avoid equipment damage. It advises against modifying CMOS LSI circuits and recommends leaving service to qualified technicians. Calibration and adjustments involve using the volume control with the power switch and adjusting the SQL control to silence receive noise at no signal conditions. The manual includes board-level guidance, such as resetting the microprocessor if the display shows invalid numbers, which erases all memories. The lithium backup battery retains memory during battery changes and lasts approximately five years. Error diagnostics include the display of “UL” on the LCD when batteries are discharged, inhibiting transmission and reception. The manual advises charging the Ni-Cd batteries with the supplied AC charger to restore operation.
Quick Issues Covered
- Diagnose power-up failures with battery and charger checks.
- Adjust squelch control to silence receive noise issues.
- Use schematic diagram for circuit tracing and troubleshooting.
Overview
The KENWOOD TR-2600A is a transceiver designed to operate within the 144 — 148 MHz frequency range. It features a high power output of 2.5W and a low power output of approximately 0.3W. The device is powered by an 8.4 V DC battery and comes with a Ni-Cd battery pack, which requires charging before use. The manual includes sections on preparation for use, controls and terminals, keyboard operation, and additional information. The transceiver is engineered to meet high-quality standards for reliable and dependable operation. It is important to follow the provided instructions to avoid equipment damage, such as using only the supplied charger or optional stands for charging.
Specifications
- 144 — 148 MHz
- RF Output Power: HI = 2.5W, LOW = 0.3 W approx.
- FM (F3), (F2 in DCS mode)
- 8.4 V DC +25%
- 8.4.V, 450 mAH (Ni-Cd battery pack)
- 9 V manganese or alkaline (not Ni-Cd)
- 6 pcs. battery case (option)
- Approx. 35 mA in receive mode with no input signal
- Less than 800 mA in HI transmit mode (at 8.4 V)
- Less than 400 mA in Low transmit mode (at 8.4 V)
- Less than 1A for memory back-up
- Negative
- —20 °C to +50 °C
- 500
- With Ni-Cd battery: 66(2.6) W x 168(6.7)H x 40(1.6)D mm(inch)
- With manganese battery: 66(2.6) W x 176(7.0)H x 40(1.6)D mm(inch)
- With Ni-Cd battery: 520 g (1.2 Ibs.)
- With manganese battery: 510 g (1.2 Ibs.)
Controls & Indicators
The front-panel controls/indicators on the KENWOOD TR-2600A include:
– DCS switch: Used to operate the digital code squelch system. Set to ON for DCS operation and OFF for normal QSO operation.
– Power Switch and Volume Control: A combined volume control with a Power ON/OFF switch. Power is turned off at the full counter-clockwise position.
– SQL control: Used to silence receive noise when no signal is present. Adjust clockwise until the noise threshold is reached. For scan operations, this control must be set to the threshold point.
– CALL indicator: Lights up during alert operation or DCS operation.
– TX/BUSY indicator: Lights red when transmitting and green when receiving.
Installation / Setup
The setup for the Kenwood TR-2600A includes several important highlights. After unpacking, it is recommended to save the box and packing material for future transport or service needs. The supplied battery pack is not charged at the factory, so it should be charged for about 15 hours before use. To load the battery pack, slide it onto the transceiver until it clicks into place. To remove it, press the release button and slide the pack off. When the battery indicator reaches the red zone, the battery should be charged using the supplied AC wall charger. During charging, the TR-2600A cannot be operated. The battery can also be charged using optional accessories like the MODEL MS-1 mobile stand or MODEL ST-2 base stand. A fully charged battery lasts for about 110 minutes with a usage pattern of 1 minute transmission and 3 minutes reception. It is important not to connect an external DC supply directly to the charge terminal and to use only the supplied charger or specified stands to avoid damage. The TR-2600A also includes a lithium back-up battery to retain memory, which is estimated to last about 5 years. If the display shows invalid numbers, the microprocessor can be reset by pressing a microswitch accessible through the rear case.
Safety & Warnings
CAUTION: DO NOT CONNECT AN EXTERNAL DC SUPPLY DIRECTLY TO THE CHARGE TERMINAL. Use only the supplied charger unit, optional base stand ST-2, or mobile stand MS-1. Extensive damage will occur if this is disregarded.
CAUTION: DO NOT ATTEMPT TO MODIFY OR OTHERWISE TOUCH CMOS LSI CIRCUITS. Leave all service to a qualified, experienced technician.
CAUTION: This is a Charge terminal only. Do not direct wire this terminal to an external power supply.
CAUTION: When the batteries have been fully charged, do not attempt to continue charging. The batteries should be charged at temperatures of 0°C~45°C.