The manual provides instructions for installing ferrites on oscilloscope cables to reduce RFI emissions and ensure compliance with CISPR 11 Class A limits for the HP 1660ES-series logic analyzer. It notes that the ferrites should be placed no more than 1 inch from the base of the probe cable and that their installation does not affect the normal operation of the analyzer or oscilloscope.
Manual Overview
The HP-ferrite-installation manual provides guidance for installing ferrites on the HP 1660ES-series logic analyzer’s accessory pouch for the HP 1160 Miniature Passive Probes. The primary purpose of these ferrites is to reduce radio frequency interference (RFI) emissions from oscilloscope probes, ensuring compliance with CISPR 11 Class A RFI limits. The installation process involves opening the ferrite and placing it no more than one inch from the base of the probe cable, then closing the ferrite around the cable. This installation does not affect the normal operation of the analyzer or oscilloscope. The manual does not include troubleshooting flow, error codes, diagnostics, calibration, adjustments, or board-level guidance. It is noted that Agilent no longer supports this product, and any further information or updates can be found on the Agilent Test & Measurement website.
Quick Issues Covered
- Diagnose RFI emissions with HP 1660ES-series logic analyzers.
- Install ferrites to meet CISPR 11 Class A RFI limits.
- Ferrite placement: within 1 inch from probe cable base.
Overview
This manual is available on the Agilent website to support users of the product, although it may be incomplete or outdated. Agilent no longer sells or supports the product, but service centers might offer calibration if no repair parts are needed. The manual may reference HP or Hewlett-Packard, which are now part of Agilent Technologies.
Specifications
Refer to the PDF for details.
Controls & Indicators
Refer to the PDF for details.
Installation / Setup
Ferrites are included in the HP 1660ES-series logic analyzer’s accessory pouch for the HP 1160 Miniature Passive Probes. When properly installed, the ferrites reduce RFI emissions from the oscilloscope probes. To ensure compliance with CISPR 11 Class A RFI limits, the ferrite must be installed to absorb radio frequency energy. The installation involves opening the ferrite, placing it no more than 1 inch from the base of the probe cable, and closing it around the cable. Adding or removing the ferrite will not affect the normal operation of the analyzer or oscilloscope.
Operation
Refer to the PDF for details.
Troubleshooting & Error Codes
Refer to the PDF for details.
Safety & Warnings
Ferrites are included in the HP 1660ES-series logic analyzer’s accessory pouch for the HP 1160 Miniature Passive Probes. When properly installed, the ferrites reduce RFI emissions from the oscilloscope probes. In order to ensure compliance of the HP 1660ES-series logic analyzer’s to the CISPR 11 Class A radio frequency interference (RFI) limits, you must install the ferrite to absorb radio frequency energy. Adding or removing the ferrite will not affect the normal operation of the analyzer or oscilloscope.
Download INST Manual (PDF – 48.7 KB)
HP Ferrite Installation INST manual assists technicians in installing ferrite components efficiently. File size: 48.7 KB.
- Brand: Hp-ferrite-installation
- Model: INST
- Type: Manual
- File size: 48.7 KB
Overview
Brief overview of the product.
Specifications
- Key spec 1
- Key spec 2
Controls & Indicators
Control panel/button layout.
Installation / Setup
- Step 1…
- Step 2…
Operation
Basic usage, modes, cycles.
Troubleshooting & Error Codes
| Issue / Code | Fix |
|---|---|
| Example | How to fix… |
Safety & Warnings
- Important warning…